Photoelectrics Retro-reflective, Polarized Type PD30CNP06....DU Miniature sensor range Range: 6 m, with reflector Sensitivity adjustment by Teach-In programming Modulated, red light 660 nm, polarized Supply voltage: 10 to 30 VDC Output: 100 mA, NPN or PNP preset Make and break switching function programmable LED indication for output, stability and power ON Protection: reverse polarity, short circuit and transients Cable and plug versions Excellent EMC performance Dust alarm output Product Description Ordering Key PD30CNP06PPM5DU The PD30CNP06 sensor The Teach-In function for Type family comes in a compact adjustment of the sensitivi- Housing style 10 x 30 x 20 mm reinforced ty makes the sensors highly Housing size PMMA/ABS housing. flexible. The output type is Housing material The sensors are useful in preset (NPN or PNP), and Housing length applications where high-ac- the output switching function Detection principle curacy detection as well as is one programmable (NO or Sensing distance small size is required. NC) and one dust output NO Output type Compact housing and high or NC. Output configuration power LED for excellent per- Connection type formance-size ratio. Dust output Type Selection Housing Range Connection Ordering no. Ordering no. W x H x D S NPN PNP n Make or break switching Make or break switching 10 x 30 x 20 mm 6 m Cable PD 30 CNP 06 NPDU PD 30 CNP 06 PPDU 10 x 30 x 20 mm 6 m Plug PD 30 CNP 06 NPM5DU PD 30 CNP 06 PPM5DU Note: Reflectors to be ordered separately Specifications EN 60947-5-2 Rated operating distance (S ) Up to 6 m, with reflector Protection Short-circuit, reverse polarity n 80 mm (ER4) and transients 4 m on ER4060 reflector Light source GaAlAs, LED, 660 nm Blind zone 100 mm Light type Red, modulated Sensing angle 2 Sensitivity Adjustable by Teach-In Ambient light 10,000 lux Temperature drift 0.1%/C Light spot 110 mm 1.5 m Hysteresis (H) Operating frequency 1000 Hz (differential travel) 10% Response time Rated operational volt. (U ) 10 to 30 VDC B OFF-ON (t ) 0.5 ms ON (ripple included) ON-OFF (t ) 0.5 ms OFF Ripple (U ) 10% rpp Power ON delay (t ) 300 ms v Output current Output function Continuous (Ie) 100 mA NPN and PNP Preset Short-time (I) 100 mA NO/NC switching function Set by button (max. load capacity 100 nF) Output configuration Dust output current Programming options Continuous (Ie) 20 mA Output pin 4 black NO or NC Short-time (I) 20 mA Output NO or NC (dust) (max. load capacity 100 nF) Dust alarm output No load supply current (Io) 30 mA 24 VDC Delay on operate 20 ms Minimum operational current (Im) 0.5 mA Indication OFF-state current (Ir ) 100 A Output ON LED, yellow Signal stability ON and power ON LED, green Voltage drop (Ud ) 2.4 VDC 100 mA Specifications are subject to change without notice (12.07.2016) 1 PD30CNP06....DU Specifications (cont.) EN 60947-5-2 Environment Rated insulation voltage 500 VAC (rms) Installation category III (IEC 60664/60664A Housing material 60947-1) Body ABS Pollution degree 3 (IEC 60664/60664A Front material PMMA, red 60947-1) Connection Degree of protection IP 67 (IEC 60529 60947-1) Cable PVC, black, 2 m 2 Ambient temperature 4 x 0.14 mm , = 3.3 mm Operating -25 to +55C (-13 to +131F) Plug M8, 4-pin (CON, 54-series) Storage -40 to +70C (-40 to +158F) Weight With cable: 40 g Vibration 10 to 55 Hz, 0.5 mm/7.5 g With plug: 10 g (IEC 60068-2-6) CE-marking Yes Shock 30 g / 11ms, 3 pos, 3 neg Approvals cULus (UL508) per axis (IEC 60068-2-6, 60068-2-32) Operation Diagram Operation Diagram tv = Power ON delay ON Power supply OFF Present Object Not Present Tv ON Make Output (N.O.) OFF Tv ON Break Output (N.C.) OFF Wiring Diagrams NPN PNP 1 BN V 1 BN V 4 BK 2 WH* 2 WH* 4 BK 3 BU 3 BU GND GND *Dust Output *Dust Output Detection Diagram Excess Gain 300 100 200 100 0 10 -100 -200 -300 1 02 46 810 0.1 110 (m) Distance (m) 2 Specifications are subject to change without notice (12.07.2016) (mm) Exess gain