Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 TRMS 3-phase over and under voltage, phase sequence, phase loss, asymmetry and tolerance monitoring relay Detect when all 3 phases are present and have the correct sequence Detect if all the 3-phase-phase or phase-neutral voltages are within the set limits Detect if asymmetry and tolerance are within the set value Separately adjustable setpoints Separately adjustable delay functions (0.1 to 30 s) Output: 2 x 8 A relay SPDT NE For mounting on DIN-rail in accordance with DIN/EN 50 022 (DPC01) or plug-in module (PPC01) DPC01 PPC01 45 mm Euronorm housing (DPC01) or 36 mm plug-in module (PPC01) LED indication for relays, alarm and power supply ON Product Description Ordering key DPC 01 D M48 3-phase or 3-phase+neutral with built-in time delay func- Housing line voltage monitoring relay tion. Function for phase sequence, phase Supply ranges from 100 to Type loss, asymmetry, tolerance, 690 VAC covered by three Item number over and under voltage (sep- multivoltage relays. Output arately adjustable set points) Power Supply Type Selection Supply: Supply: Supply: Mounting Output Frequency 100 to 115 VAC 208 to 240 VAC 380 to 415 VAC DIN-rail 2 x SPDT 50 - 60 Hz DPC 01 D M23 DIN-rail 2 x SPDT 50 - 400 Hz DPC 01 D M11 400HZ DPC 01 D M23 400HZ DPC 01 D M48 400HZ Plug-in 2 x SPDT 50 - 60 Hz PPC 01 D M23 PPC 01 D M48 Supply: Supply: Supply: Mounting Output Frequency 440 to 480 VAC 380 to 480 VAC 600 to 690 VAC DIN-rail 2 x SPDT 50 - 60 Hz DPC 01 D M48 DPC 01 D M69 DIN-rail 2 x SPDT 50 - 400 Hz DPC 01 D M49 400HZ DPC 01 D M69 400HZ Input Specifications Input Ranges L1, L2, L3, N DPC01: Terminals L1, L2, L3, N Upper level +2 to +22% PPC01: Terminals 5, 6, 7, 11 of the nominal voltage Measure their own supply Lower level -22 to -2% of the nominal voltage Note: Connect the neutral only Asymmetry 2 to 22% if it is intrinsically at the star of the nominal voltage centre Tolerance 2 to 22% Measuring ranges of the nominal voltage M11 85 to 132 VAC Note: The input voltage must M23 177 to 275 VAC not exceed the maximum rated M48 DPC01 323 to 550 VAC voltage or drop below the DPC01 400HZ 323 to 475 VAC minimum rated voltage PPC01 323 to 475 VAC reported above. M49 DPC01 375 to 550 VAC Hysteresis M69 DPC01 510 to 793 VAC Set points from 2 to 5% 1% Set points from 5 to 22% 2% Specifications are subject to change without notice (06.04.10) 1DPC01, PPC01 Output Specifications Supply Specifications Output 2 x SPDT relays N.E. Power supply Overvoltage cat. III Rated insulation voltage 250 VAC Rated operational voltage (IEC 60664, IEC 60038) through terminals: Contact ratings (AgSnO) 2 L1, L2, L3, N (DPC01) Resistive loads AC 1 8 A 250 VAC 5, 6, 7, 11 (PPC01) DC 12 5 A 24 VDC M11 - Delta Voltage: 100 to 115VAC 15% 45 to 65Hz Small inductive loads AC 15 2.5 A 250 VAC M23 - Delta Voltage: 208 to 240VAC 15% 45 to 65Hz DC 13 2.5 A 24 VDC DPC01 M48 - Delta Voltage: 380 to 480VAC 15% 45 to 65Hz 6 Mechanical life 30 x 10 operations DPC01 M48 - Star Voltage: 220 to 277VAC 15% 45 to 65Hz 5 Electrical life 10 operations PPC01 M48 - Delta Voltage: 380 to 415VAC 15% 45 to 65Hz (at 8 A, 250 V, cos = 1) PPC01 M48 - Star Voltage: 220 to 240VAC 15% 45 to 65Hz M48 400HZ - Delta Voltage: 380 to 415VAC 15% 45 to 440Hz Operating frequency 7200 operations/h M48 400 HZ- Star Voltage: 220 to 240VAC 15% 45 to 440Hz Dielectric strength M49 400HZ - Delta Voltage: 440 to 480VAC 15% 45 to 440Hz Dielectric voltage 2 kVAC (rms) M49 400 HZ- Star Voltage: 254 to 277VAC 15% 45 to 440Hz Rated impulse withstand volt. 4 kV (1.2/50 s) M69 - Delta Voltage: 600 to 690VAC 15% 45 to 65Hz M69 - Star Voltage: 347 to 400VAC 15% 45 to 65Hz M69 400HZ- Delta Voltage: 600 to 690VAC 15% 45 to 440Hz M69 400HZ- Star Voltage: 347 to 400VAC 15% 45 to 440Hz Rated operational power M11 8 VA 115 VAC, 50 Hz M23 9 VA 230 VAC, 50 Hz M48 13 VA 400 VAC, 50 Hz M69 21 VA 600 VAC, 50 Hz Supplied by L2 and L3 for the DIN-rail versions and by L1 and L2 for the Plug-in versions General Specifications Power ON delay 1 s 0.5 s or 6 s 0.5 s Housing Dimensions DPC01 45 x 80 x 99.5 mm Accuracy (15 min warm-up time) PPC01 36 x 80 x 94 mm Temperature drift 1000 ppm/C Material PA66 or Noryl Delay ON alarm 10% on set value 50 ms Repeatability 0.5% on full-scale Weight Approx. 220 g Reaction time Screw terminals (DPC01) Incorrect phase sequence Tightening torque Max. 0.5 Nm or total phase loss < 200 ms acc. to IEC 60947 Voltage level (input signal variation from Product standard EN 60255-6 -20% to +20% or from Approvals UL, CSA +20% to -20% of set value) GL (DPC01 only, except Asymmetry level 400Hz, M11) Alarm ON delay: < 200 ms (delay < 0.1 s) CE Marking L.V. Directive 2006/95/EC Alarm OFF delay: < 200 ms (delay < 0.1 s) EMC Directive 2004/108/EC Indication for EMC Power supply ON LED, green Immunity According to EN 60255-26 Alarm ON LED, red (flashing 2 Hz According to EN 61000-6-2 during delay time) Emissions According to EN 60255-26 Output relays ON 2 x LED, yellow According to EN 61000-6-3 Environment (EN 60529) Degree of protection IP 20 Pollution degree 3 (DPC01), 2 (PPC01) Operating temperature Max. voltage, 50 Hz -20 to +60C, R.H. < 95% Max. voltage, 60 Hz -20 to +50C, R.H. < 95% Storage temperature -30 to +80C, R.H. < 95% 2 Specifications are subject to change without notice (06.04.10)