Solid State Relays Industrial, 2-Pole Zero Cross Switching Type RA2A..C 2 Pole AC Solid State Relay Zero Cross Resistive AC loads Direct copper bonding (DCB) technology LED indication Rated operational current: up to 2x 40 AACrms Rated operational voltage: up to 600 VACrms Input range: 4.5- 32 VDC Blocking voltage: Up to 1200 Vp Opto-isolation: 4000 VACrms Integrated overvoltage protection Product De scrip tion Ordering Key RA 2 A 23 D 40 C This 2-pole industrial relay line voltage. The same applies Solid State Relay minimises the space to control B. LEDs indicate the Number of poles requirements in a control control status of each pole. The Zero switching cabinet without compromising optimised design is free of Rated operational voltage performance. By applying an moulding mass to reduce Control voltage input voltage on control A, the internal mechanical stress. The Rated operational current corresponding output integrated varistor across each PIN connectors for control semiconductor is activated at pole ensures protection against Option the first zero crossing of the overvoltages. Selection Guide Rated operational Blocking voltage Control voltage Max. operational current (with suitable heatsink) voltage 2 x 25 AACrms 2 x 40 AACrms 230 VACrms, ZC 650 V 4.5 - 32 VDC RA2A23D25C RA2A23D40C p 600 VACrms, ZC 1200 V 4.5 - 32 VDC RA2A60D25C RA2A60D40C p ZC = Zero Cross Switching Selection Guide - RA2A..H53 (RA2A mounted on heatsink RHS38) Rated operational Blocking voltage Control voltage Rated operational current at 40C voltage 2 x 20 AACrms* 230 VACrms, ZC 650 V 4.5 - 32 VDC RA2A23D40CH53 p * Refer to Derating Curve for other ratings Selection Guide - RA2A..S18 (attached thermal pad) Rated operational Blocking voltage Control voltage Rated operational current (with suitable heatsink) voltage 2 x 25 AACrms 2 x 40 AACrms 230 VACrms, ZC 650 V 4.5 - 32 VDC - p RA2A23D40CS18 Specifications are subject to change without notice (25.03.2019) 1RA2..C General Specifications RA2A23.. RA2A60.. Operational voltage range 24 to 265 VACrms 42 to 660 VACrms Blocking voltage 650 Vp 1200 Vp Rated isolation Input to Output 4 kVrms 4 kVrms Output to heatsink 4 kVrms 4 kVrms Operational frequency 45 to 65 Hz 45 to 65 Hz Power factor >0.95 230 VACrms >0.95 600 VACrms Zero voltage turn-on <15 V <15 V LED ON indication (x2) Yes (green) Yes (green) CE marking Yes Yes Approvals UR, cUR, EAC UR, cUR, EAC Output Specifications RA2...25 RA2...40 Rated operational current AC 51 2 x 25 AACrms 2 x 40 AACrms Minimum operational current 150 mA 250 mA Non-rep. surge current t=10 ms 325 A 600 A p p Off-state leakage current < 3 mA < 3 mA 2 2 2 I t for fusing t=10 ms 525 A s 1800 A s On-state voltage drop rated current 1.6 Vrms 1.6 Vrms Critical dV/dt off-state min. 1000 V/s 1000 V/s Zero crossing detection Yes Yes Input Speci fic at ions Housing Specifications 1 2 Control voltage range 4.5 - 32 VDC Control terminals 4 PIN connector 0.64 mm square pin with 2.54 mm Pick-up voltage 4.25 VDC centre distance Drop-out voltage 2 VDC Power terminals 4 x Fastons 6.35 x 0.8 mm Reverse Protection 32 VDC Baseplate Aluminium Input current per pole Weight Approx. 85 g max. input voltage 10m A Max. Pull out force for power Response time pick-up terminals 130 N 50 Hz 10 ms Relay Response time drop-out 50 Hz 10 ms Mounting screws M5 Mounting torque 1.5 - 2.0 Nm 1. DC control to be supplied by class 2 power source 2. Possible mating connector model CE100F22-4-D from MAS-CON 2 Specifications are subject to change without notice (25.03.2019)