Solid State Relays 1-Phase with Integrated Heatsink Proportional Switching Controllers Types RGC1P..AA.., RGC1P..V.. 1-pole analog switching AC solid state contactors Selectable mode of operation: - Phase Angle - Full Cycle x1, x4, x16 - Advanced Full Cycle - Soft Starting Rated operational voltage: up to 660 VAC Rated operational current: up to 63 AAC Control inputs: 4-20 mA, 0-5 V, 1-5 V, 0-10 V, external potentiometer Integrated varistor protection on output Load ON LED indication 100kA short circuit current rating according to UL508 DIN or panel mount Product Description Ordering Key RGC 1 P 60 V 42 E D The RGC1P is a series of solid advanced full cycle control Solid state relay state contactors (with integrat- specific for short wave infrared Number of poles ed heatsink) that give the pos- heaters and soft starting for Type of switching sibility to control output power limiting inrush current of loads Rated operational voltage of 1-phase loads with an ana- having a high temperature Control input log control input. Input types coefficient. Rated operational current cover a wide range of current Configuration layout and voltage ranges. Local set- The output of the RGC1P is External supply ting by an external potentiome- protected against overvoltages ter is possible. Switching by means of an integrated Options modes, selectable through a varistor across the output. Two front knob, allow phase angle front LEDs indicate the status control, full cycle control, of the load and control. Specifications are at a surrounding temperature of 25C unless otherwise specified. Type Selection 2 SSR with Type of Rated voltage Control Connection External Options Rated current 1 heatsink switching (Ue), Blocking input configuration supply (Us) 40C, It voltage RGC1: P: Proportional 23: 85 - 265 VAC, AA: 12: 15 AAC, 1800 As E: Contactor D: 24 VDC / AC T: Tamper proof 1-pole 800 Vp 4-20 mADC 30: 30 AAC, 1800 As A: 90 - 250 VAC cover & securness switching 42: 43 AAC, 18000 As tie included in 48: 190 - 550 VAC, V: 50: 50 AAC, 3200 As packaging 1200 Vp 0-5 VDC 62: 63 AAC, 18000 As 1- 5 VDC 60: 410 - 660 VAC, 0-10 VDC 1200 Vp External potentiometer 1: V control input versions require an external supply Us 2: Refer to Current Derating Specifications are subject to change without notice (02.04.2018) 1RGC1P..AA, RGC1P..V Selection Guide Output Control External Power Rated operational current 40C (It) voltage, input supply, connection Product width Ue Us 15 AAC 30 AAC 43 AAC 50 AAC 63 AAC (1800 As) (1800 As) (18000 As) (3200 As) (18000 As) 35 mm 35 mm 35 mm 70 mm 70 mm 85 - 265 VAC AA: - Screw RGC1P23AA12E RGC1P23AA30E - - - RGC1P23AA42E 4-20 mADC Box - - RGC1P23AA50E RGC1P23AA62E RGC1P23AA42ET V: 24 VDC/AC Screw RGC1P23V12ED RGC1P23V30ED - - - RGC1P23V42ED 0-10V, 0-5V, Box - - RGC1P23V50ED RGC1P23V62ED RGC1P23V42EDT 1-5VDC, pot 90-250 VAC Screw RGC1P23V12EA RGC1P23V30EA - - - Box - - RGC1P23V42EA - RGC1P23V62EA 190 - 550 VAC AA: Screw RGC1P48AA12E RGC1P48AA30E - - - - RGC1P48AA42E 4-20 mADC Box - - RGC1P48AA50E RGC1P48AA62E RGC1P48AA42ET V: 24 VDC/AC Screw RGC1P48V12ED RGC1P48V30ED - - - 0-10V, 0-5V, Box - - RGC1P48V42ED RGC1P48V50ED RGC1P48V62ED 1-5VDC, pot 90-250 VAC Screw RGC1P48V12EA RGC1P48V30EA - - - - - RGC1P48V42EA - RGC1P48V62EA Box 410 - 660 VAC AA: - Screw - RGC1P60AA30E - - - 4-20 mADC - - RGC1P60AA42E - RGC1P60AA62E Box V: 24 VDC/AC Screw - RGC1P60V30ED - - - 0-10V, 0-5V, Box - - RGC1P60V42ED - RGC1P60V62ED 1-5VDC, pot 90-250 VAC Screw - RGC1P60V30EA - - - Box - - RGC1P60V42EA - RGC1P60V62EA General Specifications RGC1P..AA RGC1P..V Operational frequency range 45 to 65 Hz 45 to 65 Hz Power factor > 0.7 rated voltage > 0.7 rated voltage Touch Protection IP20 IP20 3 LED status indication Green Control input Control input <4 mA, flashing 0.5s ON, 0.5s OFF 0 V, flashing 0.5s ON, 0.5s OFF >4 mA, fully on, intensity varies with input >0 V, fully ON Supply ON (Us) Supply ON (Us) n/a Flashing 0.5s ON, 0.5s OFF Yellow Load ON Load ON Pollution degree 2 (non-conductive pollution with 2 (non-conductive pollution with possibilities of condensation) possibilities of condensation) Rated impulse withstand voltage, Uimp 6 kV (1.2/50s) 6 kV (1.2/50s) Over-voltage category III (fixed installations) III (fixed installations) Isolation L1, T1, A1, A2, A3, POT, GND, Us to case 4000 Vrms 4000 Vrms L1, T1 to A1, A2, A3, Pot, GND, Us 2500 Vrms 2500 Vrms Us to A1, A2, A3, POT, GND n/a n/a (..V..ED) 1500 Vrms (..V..EA) 3: Refer to LED Indications section 2 Specifications are subject to change without notice (02.04.2018)