Solid State Relays
1-Phase with Integrated Heatsink
Soft Start Switching
Types RGC1P..K..
1-pole AC solid state contactors
Soft start switching for short wave infrared heaters
Rated operational voltage: up to 660 VAC
Rated operational current: up to 63 AAC
Control input: 24VDC
Integrated varistor protection on output
Load ON LED indication
100kA short circuit current rating according to UL508
DIN or panel mount
Product Description Ordering Key
RGC 1 P 60 K 42 E D
The RGC1P..K provides a an accessible potentiometer. Solid state relay
solution for starting of loads Once the soft start is complete,
Number of poles
having a high cold to hot resis- the RGC1P..K output switches
Type of switching
tance ratio and hence it is very ON and OFF according to the
Rated operational voltage
common for such loads to control signal. Soft starting is
Control input
exhibit a high inrush current perfomed again if the control
Rated operational current
when switched on from a cold signal has been missing for
Configuration layout
state. Such behaviour is very more than 5 seconds.
External supply
common for short wave
infrared heaters. The output of the RGC1P is
protected against overvoltages
When a control signal is by means of an integrated
applied to the RGC1P..K, a varistor across the output. Two
soft start is performed. The soft front LEDs indicate the status
start time is settable through of the load and control.
Specifications are at a surrounding temperature of 25C unless
otherwise specified.
Type Selection
1
SSR with Type of Rated voltage (Ue), Control input Rated current Connection External supply (Us)
heatsink switching Blocking voltage @40C, It configuration
RGC1: P: Proportional 23: 85 - 265 VAC, K: 24 VDC 30: 30 AAC, 1800 As E: Contactor D: 24 VDC/ AC
1-pole (Soft starting) 800 Vp +/-20% 42: 43 AAC, 18000 As
switching 62: 63 AAC, 18000 As
48: 190 - 550 VAC,
1200 Vp
60: 410 - 660 VAC,
1200 Vp
1: Refer to Current Derating
Specifications are subject to change without notice (05.04.2018) 1RGC1P..K
Selection Guide
Output Control External Power Rated operational current @ 40C (It)
voltage, input supply, connection Product width
Ue Us
30 AAC 43 AAC 63 AAC
(1800 As) (18000 As) (18000 As)
35 mm 35 mm 70 mm
85 - 265 VAC 19.2 - 28.8 VDC 24 VDC/AC - -
Screw RGC1P23K30ED
RGC1P23K42ED RGC1P23K62ED
Box -
190 - 550 VAC 19.2 - 28.8 VDC 24 VDC/AC - -
Screw RGC1P48K30ED
RGC1P48K42ED RGC1P48K62ED
Box -
410 - 660 VAC 19.2 - 28.8 VDC 24 VDC/AC - -
Screw RGC1P60K30ED
RGC1P60K42ED RGC1P60K62ED
Box -
General Specifications
Operational frequency range 45 to 65 Hz Pollution degree 2 (non-conductive pollution
with possibilities of
Power factor > 0.7 @ rated voltage
condensation)
Touch Protection IP20
Rated impulse withstand
2
LED status indication
voltage, Uimp 6 kV (1.2/50s)
Green Control ON, fully ON
Over-voltage category III (fixed installations)
Supply ON, flashing 0.5s ON, 0.5s OFF
Isolation
Yellow Load ON
L1, T1, A1, GND, Us to case 4000 Vrms
L1, T1 to A1, GND, Us 2500 Vrms
2: Refer to LED Indications section
Output Voltage Specifications
RGC1P23.. RGC1P48.. RGC1P60..
Operational voltage range (Ue) 85-265 VAC 190-550 VAC 410-660 VAC
Blocking voltage 800 Vp 1200 Vp 1200 Vp
Leakage current @ rated voltage 5 mAAC 5 mAAC 5 mAAC
Internal Varistor across output Yes Yes Yes
Output Specifications
RGC1P..30 RGC1P..42 RGC1P..62
3
Rated operational current per pole
AC-51 @ Ta=25 C 30 AAC 50 AAC 73 AAC
AC-51 @ Ta=40 C 30 AAC 43 AAC 63 AAC
AC-55b @ Ta=40 C 30 AAC 43 AAC 63 AAC
Minimum operational current 250 mAAC 500 mAAC 500 mAAC
Rep. Overload Current
PF = 0.7
UL508: T=40C, tON=1s, tOFF=9s, 50cycles 84 AAC 126 AAC 168 AAC
Maximum transient surge
current (Itsm), t=10ms 600 Ap 1900 Ap 1900 Ap
It for fusing (t=10ms), minimum 1800 As 18000 As 18000 As
Critical dv/dt (@ Tj init = 40C) 1000 V/us 1000 V/us 1000 V/us
3: refer to Current Derating
2 Specifications are subject to change without notice (05.04.2018)