Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K.. 1-pole AC solid state contactors Soft start switching for short wave infrared heaters Rated operational voltage: up to 660 VAC Rated operational current: up to 63 AAC Control input: 24VDC Integrated varistor protection on output Load ON LED indication 100kA short circuit current rating according to UL508 DIN or panel mount Product Description Ordering Key RGC 1 P 60 K 42 E D The RGC1P..K provides a an accessible potentiometer. Solid state relay solution for starting of loads Once the soft start is complete, Number of poles having a high cold to hot resis- the RGC1P..K output switches Type of switching tance ratio and hence it is very ON and OFF according to the Rated operational voltage common for such loads to control signal. Soft starting is Control input exhibit a high inrush current perfomed again if the control Rated operational current when switched on from a cold signal has been missing for Configuration layout state. Such behaviour is very more than 5 seconds. External supply common for short wave infrared heaters. The output of the RGC1P is protected against overvoltages When a control signal is by means of an integrated applied to the RGC1P..K, a varistor across the output. Two soft start is performed. The soft front LEDs indicate the status start time is settable through of the load and control. Specifications are at a surrounding temperature of 25C unless otherwise specified. Type Selection 1 SSR with Type of Rated voltage (Ue), Control input Rated current Connection External supply (Us) heatsink switching Blocking voltage 40C, It configuration RGC1: P: Proportional 23: 85 - 265 VAC, K: 24 VDC 30: 30 AAC, 1800 As E: Contactor D: 24 VDC/ AC 1-pole (Soft starting) 800 Vp +/-20% 42: 43 AAC, 18000 As switching 62: 63 AAC, 18000 As 48: 190 - 550 VAC, 1200 Vp 60: 410 - 660 VAC, 1200 Vp 1: Refer to Current Derating Specifications are subject to change without notice (05.04.2018) 1RGC1P..K Selection Guide Output Control External Power Rated operational current 40C (It) voltage, input supply, connection Product width Ue Us 30 AAC 43 AAC 63 AAC (1800 As) (18000 As) (18000 As) 35 mm 35 mm 70 mm 85 - 265 VAC 19.2 - 28.8 VDC 24 VDC/AC - - Screw RGC1P23K30ED RGC1P23K42ED RGC1P23K62ED Box - 190 - 550 VAC 19.2 - 28.8 VDC 24 VDC/AC - - Screw RGC1P48K30ED RGC1P48K42ED RGC1P48K62ED Box - 410 - 660 VAC 19.2 - 28.8 VDC 24 VDC/AC - - Screw RGC1P60K30ED RGC1P60K42ED RGC1P60K62ED Box - General Specifications Operational frequency range 45 to 65 Hz Pollution degree 2 (non-conductive pollution with possibilities of Power factor > 0.7 rated voltage condensation) Touch Protection IP20 Rated impulse withstand 2 LED status indication voltage, Uimp 6 kV (1.2/50s) Green Control ON, fully ON Over-voltage category III (fixed installations) Supply ON, flashing 0.5s ON, 0.5s OFF Isolation Yellow Load ON L1, T1, A1, GND, Us to case 4000 Vrms L1, T1 to A1, GND, Us 2500 Vrms 2: Refer to LED Indications section Output Voltage Specifications RGC1P23.. RGC1P48.. RGC1P60.. Operational voltage range (Ue) 85-265 VAC 190-550 VAC 410-660 VAC Blocking voltage 800 Vp 1200 Vp 1200 Vp Leakage current rated voltage 5 mAAC 5 mAAC 5 mAAC Internal Varistor across output Yes Yes Yes Output Specifications RGC1P..30 RGC1P..42 RGC1P..62 3 Rated operational current per pole AC-51 Ta=25 C 30 AAC 50 AAC 73 AAC AC-51 Ta=40 C 30 AAC 43 AAC 63 AAC AC-55b Ta=40 C 30 AAC 43 AAC 63 AAC Minimum operational current 250 mAAC 500 mAAC 500 mAAC Rep. Overload Current PF = 0.7 UL508: T=40C, tON=1s, tOFF=9s, 50cycles 84 AAC 126 AAC 168 AAC Maximum transient surge current (Itsm), t=10ms 600 Ap 1900 Ap 1900 Ap It for fusing (t=10ms), minimum 1800 As 18000 As 18000 As Critical dv/dt ( Tj init = 40C) 1000 V/us 1000 V/us 1000 V/us 3: refer to Current Derating 2 Specifications are subject to change without notice (05.04.2018)