Solid State Relays 1-Phase Integrated Heatsink Integrated Current Monitoring Types RGC1S Product width ranging from 22.5mm to 70mm Partial load failure detection Zero cross switching o Ratings up to 660VACrms & 85AACrms 40 C 2 2 Up to 18000A s for I t and 1200Vp for blocking voltage Control voltage range: 4 - 32 VDC Local or remote current set-point LED indications for the different faults Alarm signal output for SSR or load circuit malfunction Integrated voltage transient protection with varistor 100kA short circuit current rating according to UL508 Product Description Ordering Key RGC 1 S 60 D 30 G K E P This slim RG design is capable on the front of the device or Solid state relay of detecting various failure remotely through the provided Number of poles modes occuring to the heaters terminal. Switching mode and also to the product itself. Rated operational voltage Failures which can be detected This product is available either Control voltage include partial load failure, with integrated heatsink Rated operational current heater loss, open circuit SSR, (RGC1S series) and also with- Connection type for control short circuit SSR and SSR out heatsink (RGS1S series). Connection type for power over temperature. A normally The minimum product width is Connection configuration closed, potential free alarm, 22.5mm. The control and aux- Protection opens in the event of a system iliary terminals are double box Options or power semiconductor fault. clamps to facilitate safe loop- ing whilst the power terminals A load current setpint has to be are either screw terminals or TEACHed to the SSR either box clamps depending on the locally by the TEACH button model selected. Note: Specifications stated at 25C unless specified. Ordering Key 1 1-Phase Switching Rated V, Control Rated current 40C, Connection Connection Connection Protection 2 SSR mode Blocking V* voltage I t data input output configuration 2 RGC1: S: Zero 60:600VAC D: 4-32VDC 20: 23AAC, 525A s G: Box K: Screw E: Contactor P: Over- 2 with heatsink cross with +10% -15%, 25: 25AAC, 1800A s Clamp G: Box U: SSR temperature 2 current 1200Vp 26: 25AAC, 18000A s Clamp protection 2 sensing 30: 30AAC, 1800A s 2 31: 30AAC, 6600A s 2 41: 43AAC, 18000A s 2 61: 65AAC, 18000A s 2 90: 85AAC, 18000A s * Rated voltage, Blocking voltage 1: Refer to Derating Curves Specifications are subject to change without notice (17.01.2018) 1RGC1S Selection Guid 2 Rated output voltage, Connection Control Configuration Rated operational current (I t value) 2 2 2 2 Blocking voltage control/ power voltage 23AAC (525A s) 25AAC (1800A s) 30AAC (1800A s) 30AAC (6600A s) 600VAC, 1200Vp Box Clamp/ Screw 4 - 32VDC E RGC1S60D20GKEP RGC1S60D25GKEP RGC1S60D30GKEP RGC1S60D31GKEP 2 Rated output voltage, Connection Control Configuration Rated operational current (I t value) 2 2 2 2 Blocking voltage control/ power voltage 25AAC (18000A s) 43AAC (18000A s) 65AAC (18000A s) 85AAC (18000A s) 600VAC, 1200Vp Box Clamp/ 4 - 32VDC E RGC1S60D26GGEP RGC1S60D41GGEP RGC1S60D61GGEP RGC1S60D90GGEP Box Clamp U - RGC1S60D41GGUP RGC1S60D61GGUP - Output Voltage Specifications Operational voltage range 42-600 VAC +10% -15% on max Blocking voltage 1200 Vp Internal varistor 625V Output Specifications RGC1S..20 RGC1S..25 RGC1S..26 RGC1S..30 RGC1S..31 RGC1S..41 RGC1S..61 RGC1S..90 2 Rated operational current AC-51 Ta=25C 25.5 AAC 27 AAC 30 AAC 30 AAC 30 AAC 50 AAC 75 AAC 85 AAC AC-51 Ta=40C 23 AAC 25 AAC 25 AAC 30 AAC 30 AAC 43 AAC 65 AAC 85 AAC 3 Minimum TEACH Current 1.2 AAC 1.2 AAC 1.2 AAC 1.2 AAC 1.2 AAC 1.2 AAC 5 AAC 5 AAC Minimum partial load current 0.2 AAC 0.2 AAC 0.2 AAC 0.2 AAC 0.2 AAC 0.2 AAC 0.83 AAC 0.83 AAC Detectable partial load failure >16.67% from current setpoint for more than 120ms Rep. overload current - UL508, PF=0.9 T =40C, t =1s, t =9s, 50cycles 60 AAC 60 AAC 60 AAC 84 AAC 84 AAC 126 AAC 168 AAC 168 AAC AMB ON OFF Max.off-state leakage current 3 mAAC 3 mAAC 3 mAAC 3 mAAC 3 mAAC 3 mAAC 3 mAAC 3 mAAC Max. Transient Surge Current (ITSM) t=10ms 325 Ap 600 Ap 1900 Ap 600 Ap 1150 Ap 1900 Ap 1900 Ap 1900 Ap It for fusing (t=10ms) Minimum 525 As 1800 As 18000 As 1800 As 6600 As 18000 As 18000 As 18000 As o Critical dv/dt ( Tj init = 40 C) 1000 V/s 1000 V/s 1000 V/s 1000 V/s 1000 V/s 1000 V/s 1000 V/s 1000 V/s 2: Refer to Derating Curves 3: Refer to EMC specifications 2 Specifications are subject to change without notice (17.01.2018)