Solid State Relays Industrial, 1-Phase, 17.5mm with built-in Varistor U type connection Types RGS..U, RGS..UDIN Zero cross or Instant on switching AC solid state relay Rated Operational voltage: up to 660VAC Rated Operational current: up to 30AAC Up to 1800As for It Control voltages: 4-32 VDC, 20-275 VAC (24-190VDC) Design according to IEC/EN60947-4-2, IEC/EN60947-4-3, IEC/EN62314, UL508, CSA22.2 No. 14-13 Integrated voltage transient protection with varistor 100 kA short circuit current rating according to UL508 Option for DIN mounting (RGS...DIN) Ordering Key Product Description RGS 1 A 60 D 30 K G U Solid state relay Aim of this solid state switching provided via box clamps. Other Number of poles device is to switch heater loads options with integrated heatsink Switching mode and motor loads frequently. This are available in RGC ranges. Rated operational voltage range offers solutions up to Control voltage 30AAC in 17.5mm width. Input The RGS...DIN provides an Rated operational current connections are via a screw con- option for DIN mounting of the Connection type for control nection, having a captivated RGS series. AC51 rating Connection type for power washer allowing for safe loop- 40C is 10AAC. ing. Output connections are Connection configuration Option Specifications are at a surrounding temperature of 25C unless otherwise specified. Ordering Key 1 1 Phase SSR Rated Control Rated current, Connection Connection Connection Options with no heatsink voltage voltage Blocking voltage control power configuration RGS1A: ZC* 60: 600V D: 4 - 32 VDC 30: 30A, 1200Vp K: Screw G: Box clamp U: SSR HT: Thermal +10% -15% pad RGS1B: IO** A: 20 - 275VAC H51: Heatsink (24-190 VDC) RHS37A DIN: DIN rail mount X40: Bulk packaging of 40pcs. 1. Add suffix HT to RGS part number for RGS with attached thermal pad. Add suffix H51 to RGS part number for factory mounted RGS on heatsink RHS37A. Add suffix DIN to RGS part number for DIN rail mountable RGS. * ZC: Zero cross switching **IO: Instant-On switching Selection Guide - RGS.. Rated voltage, Blocking Connection Control Max. rated operational current (It value) 2 Switching mode voltage control / power voltage 30 AAC (1800 A s) 600VAC, ZC 1200Vp Screw/Box clamp 4-32VDC RGS1A60D30KGU Screw/Box clamp 20-275VAC, 24-190VDC RGS1A60A30KGU 600VAC, IO 1200Vp Screw/Box clamp 4-32VDC RGS1B60D30KGU Selection Guide - RGS..DIN (RGS for DIN Rail Mounting) 2 Rated voltage Blocking Connection Control Rated operational current 40C (I t value) 2 Switching mode voltage control / power voltage 10 AAC (525 A s) 600VAC, ZC 1200Vp Screw/Box clamp 4-32VDC RGS1A60D20KGUDIN Specifications are subject to change without notice (23.01.2018) 1RGS..U, RGS..UDIN Output Voltage Specifications Operational voltage range 42-600 VAC, +10% -15% on max Blocking voltage 1200 Vp Internal varistor 625V General Specifications Latching voltage Pollution degree 2 (across L1-T1) 20V (non-conductive pollution with possibilities of condensation) Operational frequency range 45 to 65Hz Rated impulse withstand 6 kV (1.2/50s) for voltage, Uimp Power factor > 0.5 Vrated Over-voltage category III CE marking Yes (fixed installations) Touch Protection IP20 Isolation Control input status continuously ON Green LED, Input to Output 4000Vrms when control input is applied Input & Output to Case 4000Vrms Input Specifications 2 RGS..D.. RGS..A.. Control voltage range 4 - 32 VDC 20 - 275 VAC, 24 (-10%) - 190 VDC Pick-up voltage 3.8 VDC 20 VAC/DC Drop-out voltage 1 VDC 5 VAC/DC Maximum Reverse voltage 32 VDC - Response time pick-up (RGS1A..) 0.5 cycle + 500s 24VDC 2 cycles 230VAC/110VDC Response time pick-up (RGS1B..) 350s 24 VDC N/A Response time drop-out 0.5 cycle + 500s 24VDC 0.5 cycle + 40ms 230VAC/110VDC Input current 40C See diagrams below See diagrams below 2: DC control to be supplied by a Class 2 power source according to UL1310 RG..D.. RG..A.. DC input current Vs Input Voltage AC input current Vs Input Voltage 2 Specifications are subject to change without notice (23.01.2018)