Solid State Relays 1-Phase with Integrated Current Monitoring Types RGS1S Product width ranging from 22.5mm to 35mm Partial load failure detection Zero cross switching Ratings up to 600VACrms & 90AACrms 2 2 Up to 18000A s for I t and 1200Vp for blocking voltage Control voltage range: 4 - 32 VDC Local or remote current set-point LED indications for the different faults Alarm signal output for SSR or load circuit malfunction IP20 protection Integrated voltage transient protection with varistor RoHS compliant Short circuit current rating 100kArms Product Description Ordering Key RGS 1 S 60 D 30 G K E P This slim RG design is capable on the front of the device or Solid state relay of detecting various failure remotely through the provided Number of poles modes occuring to the heaters terminal. Switching mode and also to the product itself. Rated operational voltage Failures which can be detected This product is available either Control voltage include partial load failure, with integrated heatsink Rated operational current heater loss, open circuit SSR, (RGC1S series) and also with- Connection type for control short circuit SSR and SSR out heatsink (RGS1S series). Connection type for power over temperature. A normally The minimum product width is Connection configuration closed, potential free alarm, 22.5mm. The control and aux- Protection opens in the event of a system iliary terminals are double box Options or power semiconductor fault. clamps to facilitate safe loop- ing whilst the power terminals A load current setpint has to be are either screw terminals or TEACHed to the SSR either box clamps depending on the locally by the TEACH button model selected. Note: Specifications stated at 25C unless specified. Ordering Key 1 1-Phase Switching Rated V, Control Rated current Connection Connection Connection Protection Options 2 SSR mode Blocking V* voltage I t data input output configuration 2 2 RGS1: S: Zero 60:600VAC D: 4-32VDC 20: 23AAC, 525A s G: Box K: Screw E: Contactor P: Over- HT : 2 with no heatsink cross with +10% -15%, 30: 30AAC, 1800A s Clamp G: Box U: SSR temperature thermal 2 current 1200Vp 31: 30AAC, 6600A s Clamp protection pad 2 sensing 61: 65AAC, 18000A s 2 92: 90AAC, 18000A s * Rated voltage, Blocking voltage 1: refer to heatsink selection tables 2: Add suffix HT to SSR part number for factory mounted thermal pad. Conditions apply. Please consult your Carlo Gavazzi sales representative for further details. Selection Guide 2 Rated output voltage, Connection Control Configuration Rated operational current (I t value in brackets) 2 2 2 Blocking voltage control/ power voltage 23AAC (525A s) 30AAC (1800A s) 30AAC (6600A s) 600VAC, 1200Vp Box Clamp / Screw 4 - 32VDC E RGS1S60D20GKEP RGS1S60D30GKEP RGS1S60D31GKEP 2 Rated output voltage, Connection Control Configuration Rated operational current (I t value in brackets) 2 2 Blocking voltage control/ power voltage 65AAC (18000A s) 90AAC (18000A s) 600VAC, 1200Vp Box Clamp/ Box Clamp 4 - 32VDCE- RGS1S60D92GGEP U RGS1S60D61GGUP - Specifications are subject to change without notice (11.04.2016) 1RGS1S Output Specifications RGS1S..20 RGS1S..30 RGS1S..31 RGS1S..61 RGS1S..92 3 Max. AC-51 rating 23 AAC 30 AAC 30 AAC 65 AAC 90 AAC Minimum TEACH Current 1.2 AAC 1.2 AAC 1.2 AAC 5 AAC 5 AAC Minimum partial load current 0.2 AAC 0.2 AAC 0.2 AAC 0.83 AAC 0.83 AAC Detectable partial load failure >16.67% from current setpoint for more than 120ms Rep. overload current - UL508, PF=0.9 TAMB=40C, tON=1s, tOFF=9s, 50cycles 60 AAC 84 AAC 84 AAC 168 AC 168 AAC Max.off-state leakage current 3 mAAC 3 mAAC 3 mAAC 3 mAAC 3 mAAC Max. Transient Surge Current (Itsm) t=10ms 325 Ap 600 Ap 1150 Ap 1900 Ap 1900 Ap It for fusing (t=10ms) Minimum 525 As 1800 As 6600 As 18000 As 18000 As o Critical dv/dt ( Tj init = 40 C) 1000 V/us 1000 V/us 1000 V/us 1000 V/us 1000 V/us 3: refer to heatsink selection tables Output Voltage Specifications Operational Voltage Range 42-600 VAC +10% -15% on max Blocking Voltage 1200 Vp Internal Varistor 625V General Specifications Latching voltage Pollution degree 2 (non-conductive pollution with (across L1-T1) 20 VAC possibilities of condensation) Operational frequency Over-voltage category III (fixed installations) range 45 - 65 Hz Isolation Power factor > 0.9 Vrated Input to Output IN1, IN2, A1+, A2- to L1, T1 2500Vrms Touch protection IP20 Alarm to Output LEDs status indication 11+, 12- to L1 , T1 2500Vrms Supply ON Green, half intensity Control ON Green, full intensity Alarm to Input Load ON Yellow 11+, 12- to A1+, A2-, IN1, IN2 500Vrms 4 Fault Red Input & Output to Case 4000Vrms 4: refer to Alarm LED Indications 2 Specifications are subject to change without notice (11.04.2016)