Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P AC semiconductor contactor Multi-function - 5 selectable modes of operation: Phase Angle, Distributed Full Cycle and Burst Control (1, 3 and 10s) Direct copper bonding (DCB) technology LED-indication for control and load status Operational ratings up to 50 AACrms and 600 VAC 4-20mA or 0-10V control input Built-in varistor Blocking voltage: Up to 1200Vp Opto-isolation > 4000VACrms Cage clamp terminals IP20 protection Option for over-temperature protection with alarm output Product Description Ordering Key RJ 1 P 48 V 50 E P PO The Solitron Midi Analog Control. This multi-function Solid State Relay Switching is a single-phase selection makes this device Number of poles SSR that provides proportional ideal for the control of a variety Switching mode (Proportional) output power in relation to the of loads, including heaters and Rated operational voltage control signal level applied. lamps. The control signal can Control input type This microprocessor-based be either 4 - 20mA or 0 - Rated operational current device provides for 5 different 10VDC. 4mA or 0V correspond Terminal layout switching modes integrated to zero output power, whilst Over-temperature protection into one package. A selector 20mA or 10VDC correspond to Alarm output type switch on the front of the full output power. device is used for the selection of the preferred mode of oper- The product is ready to mount ation, i.e., either Phase Angle, on DIN-rail or chassis and Distributed Full Cycle or Burst comes with integral heatsink. Type Selection Switching Rated operational Control Rated operational Terminal Protection Alarm mode voltage input current layout output type 1 P: Proportional 23: 230VACrms V: 0 - 10VDC 30: 30AACrms E: Contactor P: Over- PO: * 2 Output 48: 480VACrms I: 4 - 20mA 50: 50AACrms temperature NO: * 60: 600VACrms protection 1 * PNP, Normally Open 2 * NPN, Normally Open Selection Guide Rated operational Blocking Control Supply Alarm Rated operational current voltage voltage input voltage output type 30 A 50 A 230VACrms 650Vp 0-10VDC 24VAC/DC - RJ1P23V30E RJ1P23V50E PO RJ1P23V30EPPO RJ1P23V50EPPO 4-20mA - RJ1P23I30E RJ1P23I50E PO RJ1P23I30EPPO RJ1P23I50EPPO 480VACrms 1200Vp 0-10VDC 24VAC/DC - RJ1P48V30E RJ1P48V50E PO RJ1P48V30EPPO RJ1P48V50EPPO 4-20mA - RJ1P48I30E RJ1P48I50E PO RJ1P48I30EPPO RJ1P48I50EPPO 600VACrms 1200Vp 0-10VDC 24VAC/DC - RJ1P60V30E RJ1P60V50E 4-20mA - RJ1P60I30E RJ1P60I50E Note: Alarm Output: EPNO (NPN, normally open) and 600V types available only on request Specifications are subject to change without notice (24.08.2012) 1RJ1P General Specifications RJ1P23... RJ1P48... RJ1P60... Operational voltage range 90 to 265VAC 200 to 550VAC 410 to 660VAC Blocking voltage 650V 1200V 1200V p p p Operational frequency range 45 to 65Hz 45 to 65Hz 45 to 65Hz Output power 0 to 99% 0 to 99% 0 to 99% Power factor 0.9 230VACrms 0.9 480VACrms 0.9 600VACrms Load status indication Red LED Red LED Red LED Output power resolution MODE 1 Phase Angle 1/300 50Hz, 1/300 60Hz MODE 2 Full Cycle 1/64 50Hz, 1/64 60Hz MODE 3 Burst with 1s period 1/50 50Hz, 1/60 60Hz MODE 4 Burst with 3s period 1/150 50Hz, 1/180 60Hz MODE 5 Burst with 10s period 1/500 50Hz, 1/600 60Hz Approvals UL, cUL* CE-marking Yes * Approvals pending for RJ1P...P.O models Input Specifications RJ1P..V... RJ1P..I... Voltage controlled input Current controlled input Supply voltage range, Vss 20 - 28VAC/DC Control current range 4 - 20mA Supply current 18mA 24VDC Max. allowable input current 50mA 23mA 24VAC Pick up current 4.2mA Control voltage range, Vcc 0 - 10VDC Drop out current 3.9mA Control input current 0.1mA 10VDC Control status indication Green LED Reverse polarity protected Yes Reverse polarity protected Yes Pick up voltage 0.5VDC Voltage drop 10VDC 20mA Drop out voltage 0.05VDC Control status indication Green LED Note: the use of twisted pair cable for the control input is recommended Output Specifications RJ1P...30 RJ1P...50 Rated operational current AC51 Ta=25C 30AACrms 50AACrms Min. operational current 150mAACrms 500mAACrms Rep. overload current t=1 s (Tj init.=25C) < 55AACrms < 200AACrms Non-rep. surge current t=10 ms (Tj init.=25C) 325Ap 1900Ap Off-state leakage current, rated voltage and frequency < 3 mArms < 3 mArms 2 2 2 I t for fusing t=10 ms 525A s 18000A s On-state voltage drop rated current 1.6Vrms 1.6Vrms Critical dV/dt off-state 1000V/s 1000V/s Isolation Thermal Specifications Operating temperature -20 to +70C (-4 to +158 F) Rated isolation voltage Input to output 4000 VACrms Storage temperature -40 to +100C (-40 to +212 F) Output to case 4000 VACrms 2 Specifications are subject to change without notice (24.08.2012)