Solid State Relays Industrial, 1-Phase Analog Switching Type RM1E AC Solid State Relay Analog switching (phase-angle control) for resistive and slightly inductive load applications 4 - 20mA or 0 -10V control input Rated operational current: 25, 50, 75, 100 and 125 AACrms Rated operational voltage: Up to 600 VACrms Variable intensity LED-indication according to input current Integral snubber network Polarized lockable control connector for safe connection for voltage controlled version RM1E..AA RM1E..V Product Descrip tion Ordering Key RM 1E 60 AA 50 The analog switching relay zero output power whilst 20 Solid State Relay works in accordance with the mA or 10VDC correspond to Number of Poles phase angle control prin ci ple, full output power (near linear Switching mode i.e., the output switching point power response). The relay Rated operational voltage in the AC sine wave depends switches off every time the out- Control input on the control input which can put cur rent cross es zero, and Rated operational current be either 4-20mA or 0-10VDC. switches ON in accord ance 4 mA or 0VDC correspond to with the applied control input. Type Selection Switching mode Rated operational Rated operational Control input voltage current E: Analog switching 23: 230 VACrms* 25: 25 AACrms AA: 4 - 20 mADC 40: 400 VACrms 50: 50 AACrms V: 0-10VDC** 48: 480 VACrms 75: 75 AACrms 60: 600 VACrms 100: 100 AACrms 125: 125 AACrms * For nominal operational voltage of 110VACrms, use RM1E23... ** RM1E..V.. require an external supply voltage Selection Guide Rated Blocking Control Rated operational current op. voltage voltage input 25 A 50 A 75A 100 A 125 A 230 VAC 650 V 4 - 20 mA RM1E23AA25 RM1E23AA50 RM1E23AA100 RM1E23AA125 p 0-10 VDC RM1E23V25 RM1E23V50 RM1E23V100 RM1E23V125 400 VAC 850 V 4 - 20 mA RM1E40AA25 RM1E40AA50 RM1E40AA100 p 480 VAC 1200 V 4 - 20 mA RM1E48AA25 RM1E48AA50 RM1E48AA75 RM1E48AA100 RM1E48AA125 p 0-10 VDC RM1E48V25 RM1E48V50 RM1E48V100 RM1E48V125 600 VAC 1400 V 4 - 20 mA RM1E60AA25 RM1E60AA50 RM1E60AA100 p 0-10 VDC RM1E60V25 RM1E60V50 RM1E60V100 General Spec ifi ca tions RM 1E 23 ... RM 1E 40 ... RM 1E 48 ... RM 1E 60 ... Operational voltage range RM1E..AA.. 90 to 280 VAC 340 to 460 VAC 200 to 550 VAC 410 to 660 VAC RM1E..V.. 90 to 265 VAC - 200 to 550 VAC 410 to 660 VAC Blocking voltage 650 V 850 V 1200 V 1400 V p p p p Operational frequency range 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz Power factor > 0.75 > 0.75 > 0.75 > 0.75 Approvals UR, cUR, CSA, EAC UR, cUR, CSA, EAC UR, cUR, CSA, EAC UR, cUR, CSA, EAC CE-marking Yes Yes Yes Yes* * Heatsink must be connected to ground for 600V types Specifications are subject to change without notice (06.09.2017) 1 RM1E Output Spec i fi ca tions RM1E...25 RM1E...50 RM1E...75 RM1E...100 RM1E...125 Rated operational current AC51 Ta=25 C 25 AACrms 50 AACrms 75 AACrms 100 AACrms 125 AACrms AC53a Ta=25 C 5 AACrms 15 AACrms 20 AACrms 20 AACrms 30AACrms Minimum operational current 150 mA 250 mA 400 mA 400 mA 500 mA Rep. overload current t=1s 55 AACrms 125 AACrms 150 AACrms 150 AACrms 200 AACrms Non-rep. surge current t=10ms 325 A 600 A 1150 A 1150 A 1900 A p p p p p Off-state leakage current < 3 mA < 3 mA < 3 mA < 3 mA < 3 mA 2 2 2 2 2 I t for fusing t= 10 ms 525 A s 1800 A s 6600 A s 6600 A s 18000 As Critical dV/dt off-state min. 1000 V/s 1000 V/s 1000 V/s 1000 V/s 1000 V/s Input Spec ifi cations RM1E..AA.. RM1E..V.. Current controlled input Voltage controlled input Control current range (A1-A2) 4-20 mADC Supply voltage, Vss (A3-A2) 24 VDC 20% Max. supply current 15 mA 19.2 VDC Pick up current 4.2 mADC 20 mA 30 VDC Drop out current 4.1 mADC Control voltage, Vcc (A1-A2) 0-10VDC Response time (input to output) 20 ms Pick up voltage 0.2 VDC Voltage drop < 10 VDC 20 mA Drop out voltage 0.1VDC Dynamic impedance 330 Control input current 0.15 mA 10 VDC Max. allowable input current 50 mA Response time (input to output) 20 ms Reverse polarity protected Yes Supply reverse protected Yes Note: The use of twisted pair cable for the control input is recommended Output Power Dissipation 140 R M1E..125 120 RM1E..100 100 R M 1E..75 80 R M 1E..50 60 R M 1E.60..50 40 R M1E..25 20 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Load current per pole in AACrms 2 Specifications are subject to change without notice (06.09.2017) Power dissipation in W