Dupline Plug & Play Master Module Interface for Omron Type G 3496 0004 Interface for Omron PLC with the function of a master Plug and play: Automatic communication with specific PLC/Controllers Built-in normal Dupline Channel Generator 128 I/Os and DC power supply on 3 wires RS232/RS422/RS485 port for interfacing to control sys- tem Split-I/O mode selectable (128 inputs and 128 outputs) LED-indications for supply, Dupline carrier and Com- port Tx Galvanically isolated Com-port supplied by internal DC/ DC converter Product Description Ordering Key G 3496 0004 700 G 3496 0004 is designed as channel generator, power Type: Dupline a cost-effective solution for supply synchronization H4-Housing interfacing Dupline I/Os to (enables 3-wire system with Combined module a Omron PLC. It performs supply) and RS232/RS422/ Interface type three functions: Dupline RS485 interface. DC supply Type Selection Supply PLC Interface Conformance Ordering no. 20-30 VDC Omron CPM, CPM1A, CQM, SRM1 & C200 G 3496 0004 700 Input/Output Specifications Input/Output Specifications (Cont.) Power output 4-wire RS 485/RS 422 Output voltage 20-30 VDC (pulsating) R Data line + (B) Pin 3 Output current < 3.0 A 50C R Data line - (A) Pin 8 Short circuit protection 4 A quick acting fuse S Data line + (B) Pin 2 Output voltage drop < 1.0 V S Data line - (A) Pin 7 Direction Pin 4 Dupline carrier (Connect to GND pin 5 Output voltage 8.2 V (pulsating) when using 4-wire commu- Current < 60 mA nication) Short circuit protection Yes RS 232 Scan time TX Pin 1 128 channels 132.2 ms RX Pin 9 64 channels 69.8 ms GND Pin 5 Communication port Standard RS232/RS422/RS485 Split I/O mode Yes, selectable Normal Dupline mode Yes, selectable Supply Specifications Connection 9 pole female Sub-D Dielectric voltage Com-port Dupline 1 kVAC (rms) Power supply Overvoltage cat. III (IEC 60664) Protocol HostLink Operational voltage (V ) 20-30 VDC in Baud rate 9600 (Omron Default) Reverse polarity protection None 19200 Current consumption < 150 mA + Power load Data bits 7 Power dissipation < 5 W Start bit 1 Transient protection voltage 800 V Stop bit 2 Dielectric voltage Parity Even Supply - Dupline None Flow-control None Supply - com-port 1 kVAC (rms) Pin assignment 2-wire RS 485 S/R Data line + (B) Pin 3 S/R Data line - (A) Pin 8 Note: Use individual power supplies for all G349600xx700, GND Pin 5 as the input are not galvanic isolated from each other. Specifications are subject to change without notice (04.12.2014) 1 G 3496 0004 General Specifications Power ON delay 2 s Humidity (non-condensing) 20 to 80% Indication for Mechanical resistance Com-port Tx LED, red Shock 15 G (11 ms) Supply ON LED, green Vibration 2 G (6 to 55 Hz) Dupline carrier LED, yellow Dimensions H4-Housing Environment Weight 100 g Pollution degree 3 (IEC 60664) Operating temperature 0 to +50C (+32 to +122F) Storage temperature -50 to +85C (-58 to +185F) Mode of Operation The Dupline Master Module Dupline I/Os will be read/ will also be activated. Dupline output(s) coded to (DMM) controls a 3-wire bus written by the DMM and then B5. The Dupline outputs are with signal, DC-power and sent to the PLC. Consequently, a Dupline - controlled exclusively through common GND. The DMM output can either be activat- the output data received from is connected to a standard The DMM can run in two dif- ed through the output-data the PLC. In this mode, up DC-supply, which it synchron- ferent modes Normal mode received on DMM or by an to 128 Dupline inputs and izes with the Dupline carrier and split I/O mode. In Normal active Dupline input coded for 128 Dupline outputs are signal before it is output to mode, Dupline operates as the same Dupline -address. In available, since an input and supply. The synchronization is a peer-to-peer system, where Split I/O mode, the channel an output coded to the same necessary in order to enable the channel generator auto- generator treats the Dupline Dupline address can operate the Dupline and DC-supply to matically establishes a con- inputs and Dupline outputs independently. share the GND-wire. nection between Dupline independently. If e.g. an input inputs and Dupline outputs coded for B5 is activated, the The Dupline Master Module is which are coded to the same DMM will make the informa- a Dupline Channel Generator Dupline address. If e.g. an tion available for the PLC (like with the function of a mas- input coded for B5 is activat- in normal mode), but it will ter. This means that the 128 ed, the output(s) coded for B5 not automatically activate the Dip-Switch Setting Memory Mapping Sw.3 On: 19200 baud Table of the memory mapping to the PLC Off: 9600 baud (Default Omron setting) Dupline Omron Dupline Omron Sw.4 On: Split I/O Channel Generator Mode Channel Channel (See Mode of Operation) Read Write Read Write Off: Normal Dupline Monostable Channel A1 LR0000 LR0800 E1 LR0200 LR1000 Generator Mode A2 LR0001 LR0801 F1 LR0208 LR1008 Sw.5 On: 64 Dupline channels A3 LR0002 LR0802 G1 LR0300 LR1100 Off: 128 Dupline channels A4 LR0003 LR0803 H1 LR0308 LR1108 A5 LR0004 LR0804 I1 LR0400 LR1200 A6 LR0005 LR0805 J1 LR0408 LR1208 Wiring Diagram A7 LR0006 LR0806 K1 LR0500 LR1300 A8 LR0007 LR0807 L1 LR0508 LR1308 B1 LR0008 LR0808 M1 LR0600 LR1400 B8 LR0015 LR0815 N1 LR0608 LR1408 1 23 4 5 6 7 8 C1 LR0100 LR0900 O1 LR0700 LR1500 D1 LR0108 LR0908 P1 LR0708 LR1508 3W RS 232 RS 485 + - 21 22 23 24 25 26 27 28 Supply in Power out 20-30 V DC GND Dupline Signal 2 Specifications are subject to change without notice (04.12.2014)