Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD, RSBT Soft starting of 3-phase scroll compressors up to 45Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user settings required) 2- (RSBD) and 3-Phase (RSBT) controlled solutions Current balancing strategy (RSBD models) Integrated bypass relays Internally supplied Short ramp up time: <600ms Rated operational voltage: 220VAC, 400VACrms, 50/60Hz 1 1 1 Rated operational current: 12 , 16, 25, 32, 37 , 45 AAC Over-temperature, Overcurrent, Locked Rotor protection 1 cULus, CE, RoHS compliant, CCC HP version for multi-compressor systems VDE approved (Up to 32AAC) - for RSBT...HPV models Note: Other models (RSBT) only VDE approved up to 15Arms Product Description Ordering Key RSB T 40 16 E V 11 H P V Compressor Soft Starter RSBD and RSBT are easy to RSBD is a 2-phase controlled Controlled Phases use soft starters for scroll solution and RSBT is a 3- Operational Voltage compressors up to 45Amp phase controlled solution. Rated Operational Current (RSBD) and 32Amp (RSBT) RSBD and RSBT are Control Voltage nominal current. The units are internally bypassed resulting Version equipped with a patented in less heat dissipation inside Optimised algorithm for multi-compressor auto-adaptive algorithm that the panel. systems and high pressure starts automatically adapts itself to 2 VDE approved versions (up to 32Arms) the specific compressor it is Short Circuit and Overload controlling ensuring that an protection are not provided optimum inrush current with the controller and must reduction is achieved. be procured separately. Type Selection Rated Operational Type Operational Voltage Ue Control Voltage Uc Version Current Ie 40C 1 2 RSBD 40: 220 400 VAC 12: 12 Arms E: 110 400 VAC V11: DIN Mount 2 2-Controlled +10% -15% 16: 16 Arms +10% -15% V21: DIN Mount & RFPMV00 module ready mounted 2 phases V51: DIN Mount (UL approved) 25: 25 Arms 1 32: 32 Arms F : 24VAC/DC V61: DIN Mount & RFPMV00 module ready mounted 1 2 (UL approved) 37: 37 Arms +10% -15% 1 V..HP: Optimised algorithm for multi-compressor 50: 45 Arms systems & high pressure starts V.HPV: VDE approved (up to 32AAC) RSBT 22: 220VAC, +10% -15% 3-Controlled 40: 400VAC, +10% -15% phases Operational Versions Control HP Algorithm VDE Approved Operational Type Current Voltage (up to 32Arms) Voltage 12 16 25 E V51 RSBD 40 HP 32 F V61 37 50 V11 22 V61 16 RSBT E 40 25 HP V 32 V11 V21 V51 V61 1 Applies to RSBD40 models only 2 Applies to RSBT.. HPV models only Options Specifications are subject to change without notice (20.11.2014) 1RSBD40... V.. HP, RSBT... EV... Selection Guide: RSBD (2-phase controlled) Rated Operational Current Control Version Voltage 12 Arms 16 Arms 25 Arms 32 Arms 37 Arms 45 Arms RSBD4012EV51HP RSBD4016EV51HP RSBD4025EV51HP RSBD4032EV51HP RSBD4037EV51HP RSBD4050EV51HP 110 400 VAC RSBD4012EV61HP RSBD4016EV61HP RSBD4025EV61HP RSBD4032EV61HP RSBD4037EV61HP RSBD4050EV61HP V51HP V61HP RSBD4012FV51HP RSBD4016FV51HP RSBD4025FV51HP RSBD4032FV51HP RSBD4037FV51HP RSBD4050FV51HP 24VAC/DC RSBD4012FV61HP RSBD4016FV61HP RSBD4025FV61HP RSBD4032FV61HP RSBD4037FV61HP RSBD4050FV61HP Selection Guide: RSBT (3-Phase Controlled) Operational Approvals Version Rated Operational Current Voltage 16 Arms 25 Arms 32 Arms 220 VAC RSBT2216EV11HP RSBT2225EV11HP RSBT2232EV11HP V11/V11HP RSBT4016EV11 RSBT4025EV11 RSBT4032EV11 CE V21HP 400 VAC RSBT4016EV11HP RSBT4025EV11HP RSBT4032EV11HP RSBT4016EV21HP RSBT4025EV21HP RSBT4032EV21HP 220 VAC RSBT2216EV61HP RSBT2225EV61HP RSBT2232EV61HP CE, V51HP cULus V61HP RSBT4016EV51HP RSBT4025EV51HP RSBT4032EV51HP 400 VAC RSBT4016EV61HP RSBT4025EV61HP RSBT4032EV61HP 220 VAC RSBT2216EV11HPV RSBT2225EV11HPV RSBT2232EV11HPV V11/V11HP CE RSBT4016EV11HPV RSBT4025EV11HPV RSBT4032EV11HPV V21HP 400 VAC RSBT4016EV21HPV RSBT4025EV21HPV RSBT4032EV21HPV 220 VAC RSBT2216EV61HPV RSBT2225EV61HPV RSBT2232EV61HPV CE, V51HP cULus V61HP RSBT4016EV51HPV RSBT4025EV51HPV RSBT4032EV51HPV 400 VAC RSBT4016EV61HPV RSBT4025EV61HPV RSBT4032EV61HPV General Specifications Starting Method Current limit, auto-adaptive Status Indication LEDs Ramp-up time < 600 msec Power Supply ON Green LED Ramp-down time 0 sec Recovery Mode (alarm condition) Flashing Red LED Initial Torque Initial torque will vary indirectly Alarm Red LED through the variation of the 3 Special alarm Green LED OFF current limit through the auto- and Red LED ON adaptive algorithm Form Designation 1 Undervoltage/Overvoltage protection Vibration Acc. To IEC60068-2-26 Recovery from Undervoltage RSBD40 174 VAC Frequency 1 2 +3/-0 Hz to 25Hz RSBT22 190 VAC Displacement +/- 1.6mm RSBT40 330 VAC Frequency 2 Acc. To IEC60068-2-26 25Hz to 100Hz 2g Recovery from Overvoltage 2 (19.96m/s ) RSBD40 470 VAC RSBT22 250 VAC RSBT40 470 VAC 1 Applies to RSBD models only 2 Applies to RSBT models only 3 Applies to RSBT...HPV models only 2 Specifications are subject to change without notice (20.11.2014)