Photoelectrics Amplifier, -Processor Controlled Type S1430, 3 Inputs/3 Outputs -Processor controlled Amplifier unit for 3 sets of photoelectrics 3 independent outputs NPN/PNP both NO or NC selectable Self-diagnostic functions Alignment failure indication Multivoltage 12 to 30 VAC/DC Modulated and synchronized light Adjustable sensitivity for each channel LED indications: supply, outputs, signal quality 11-pin plug-in housing For 115 or 230 VAC use power supplys S1430 PWS115 or S1430 PWS230 Product Description Ordering Key S14 30 UAP 912 -Processor controlled ampli- diagnostics for system test. Type fier for 3 sets of photoelec- Protected against short-cir- Special function tric sensors, type MOFTR, cuits, reverse wiring or cross Output type MKFTR, MIFTR or MHFTR. talk from adjecent photoelec- Power supply Utilising an 11-pin cirkular trics. Multi-voltage power plug for easy connection, supply. Sensitivity is indivi- outputs freely selectable for dually adjustable for each NPN/PNP or NO/NC. Self- set of photoelectrics. Type Selection Plug type Ordering no. Ordering no. Ordering no. Supply: 12 - 30 VAC/DC Supply: 115 VAC Supply: 230 VAC Circular, 11 pins S 1430 UAP 912 S 1430 PWS 115 S 1430 PWS 230 Power Supply for Power Supply for S 1430 UAP 912 S 1430 UAP 912 Specifications Rated operational voltage U Current 300 mA short-circuit B pins 2 & 10 DC 10.8 to 33 VDC protected AC 10.8 to 33 VAC, 45 to 65 Hz Output resistance 10 W Receiver Rx1: Pin 4 Rated operational power Rx2: Pin 7 AC supply 4 VA Rx3: Pin 8 DC supply 3 W Shield: Pin 5 (common) Power ON delay (t ) < 300 ms v Supply voltage (open loop) 5 VDC Output function NPN and PNP switching Short-circuit current 10 mA Make and break function Input resistance 470 W DIP-switch selectable Sensitivity 2 ranges, Output current (% of S ) DIP-switch selectable n Continuous (I ) 100 mA per output e - low sensitivity (25%) Short-time (I) 100 mA max. - high sensitivity (100%) Sensitivity adjustment Min. load current (I ) 0.5 mA m with 270: OFF-state current (I ) Max. 100 A r Turn knob on CH 1, 2, 3 Voltage drop (U ) 3.5 VDC d Note: Maximum range indi- Protection, outputs Reverse polarity, short-circuit, cated on photoelectric transients switch data sheet in high sensitivity range only Supply to photoelectric switch Operation within low Emitter Tx1: Pin 1 sensitivity range, increa- Tx2: Pin 9 ses ambient light and Tx3: Pin 6 crosstalk immunity Shield: Pin 11 (common) Supply voltage (open loop) 7 V square wave Specifications are subject to change without notice 1S 1430 Specifications (cont.) Truth Table Operating frequency (f) Make switching Break switching Light/dark ratio 1:1 16 Hz Response time Object present Yes No No Yes No No OFF-ON (t ) 20 ms ON ON-OFF (t ) 20 ms Dirt on lenses, OFF 1) 1) misaligned or -- No Yes -- No Yes Indication sensitivity too low Supply ON LED, green Output ON LED, yellow Output LED yellow OFF ON ON OFF ON ON Signal quality LED, red ON ON Environment or or Level LED red OFF OFF OFF OFF Overvoltage category III (IEC 664) flashing flashing Degree of protection IP 20 (IEC 529, 947-1) Output NPN/PNP OFF ON ON ON OFF OFF Pollution degree 3 (IEC 664/664A, 947-1) 1) Under normal operating conditions, the red level indication Temperature LED has to be OFF. The level indication LED will turn on Operating -20 to +50C (-4 to +122F) shortly each time an object enters or exits the sensing Storage -50 to +85C (-58 to 185F) zone, even if the photoelectric switch is correctly installed Weight 150 g and adjusted. Operation Diagram Signal strength Time Power supply Object present Signal quality Break switching Make switching Dimensions DIP-switch (located behind cover): 35 1: PNP/NPN CH 1 output 2: PNP/NPN CH 2 output 3: PNP/NPN CH 3 output SW 1 2 3 4 5 6 4: Low sensitivity (25%) / high sensitivity (100%) 5: Test button, transmitters are transmitting, no short, wired correctly 6: Test button, receivers are receiving, no short, wired correctly 5+6 together: System test (transmitter and receiver) sw 1, 2, 3: sw 4: PNP make/NPN break Range 25% NPN make/PNP break Range 100%, normal operation 84 sw 5: sw 6: Transmitter test Receiver test Normal operation Normal operation sw 5+6: System test Normal operation 4 75 5 2 Specifications are subject to change without notice 80