T t y f p e r p e a g p Switching Power Supply Type SPD 5W DIN rail mounting Universal AC input full range Installation on DIN rail 7.5 or 15mm Short circuit protection Overload protection High efficiency LED indicator for DC power ON LED indication for DC low Internal input filter CE, TUV approved and cULus Listed Product De scrip tion Ordering Key SP D 12 05 1 B The Switching power supplies and compact dimensions and Model SPD series are specially performance are a must. Mounting ( D = Din rail ) designed to be used in all Output voltage automation application where Output power the installation is on a DIN rail Input Type Optional features Input type: 1= single phase Approvals Optional Features Description Code Rheinland Product Safety Spring connectors B Output Performances INPUT OUTPUT OUTPUT OUTPUT EFF. EFF. EFF. MODEL NO. VOLTAGE WATTAGE VOLTAGE CURRENT (min.) (typ.) (avg.) Single Output Models SPD05 90~264 VAC 5 WATTS + 5 VDC 1000 mA 67% 83% 69% SPD12 90~264 VAC 5 WATTS +12 VDC 420 mA 70% 86% 72% SPD15 90~264 VAC 5 WATTS +15 VDC 340 mA 70% 87% 72% SPD24 90~264 VAC 5 WATTS +24 VDC 210 mA 70% 87% 72% Output Data Line regulation 1% Rated continuous loading 5V Model 1.0A 5VDC/0.85A 5.75VDC Load regulation 2% 12V Model 0.42A 12VDC/0.36A 13.8VDC Minimum load 0 15V Model 0.34A 15VDC/0.28A 17.25VDC Turn on time (full resistive load) 1000ms max 24V Model 0.21A 24VDC/0.17A 28.8VDC Transient recovery time 2ms Reverse voltage 5V Model VDC 7.5 Ripple and noise 50mVpp 12V Model VDC 18 Output voltage accuracy 1% 15V Model VDC 22 Temperature coefficient 0.03%/C 24V Model VDC 35 Hold up time Vi= 115VAC 30ms Capacitor load 7000 F Vi= 230VAC 130ms Voltage rise time at 150ms max Voltage fall time (I nom) 150ms max 0 full resistive load 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 17/05/16 t p r a r u o a v B e dSwitching Power Supply Type SPD 5W DIN rail mounting Input Data Rated input voltage 100 - 240VAC Power dissipation (Vi : 230VAC, Io nom) 5V Model 2.2W Voltage range 12V Model 1.9W AC 90 - 265VAC 15V Model 2.1W DC 120 - 370VDC 24V Model 1.8W Rated input current Frequency range 47- 63Hz (Vi : 115VAC, Io nom) Typ. 115mA Max. 200mA Leakage current Input-Output 0.25mA Inrush current 3.5mA Vi= 115VAC 10A Vi= 230VAC 18A Controls and Protections Overload 110 135% Over voltage protection 125 - 145% 1) Input fuse T2A/250VAC internal Internal surge voltage protection Varistor (IEC 61000-4-5) Output short circuit Hiccup mode 1) Fuse not replaceable by user General Data ( nominal line, full a, 25C ) Ambient temperature -20C to 71C MTBF (Bellcore issue 6 40C, GB) 5V Model 802000 Hours Derating (>61C to +71C) 2.5%/C 12V Model 805000 Hours Ambient humidity 20 ~ 95%RH 15V Model 808000 Hours Storage -25C to +85C 24V Model 812000 Hours Protection degree IP20 Case material Plastic: PC, UL94-V0 Cooling Free air convection Pollution degree 2 Insulation voltage Altitude 4850m Input-Output 3.000VAC/4242VDC min Dimensions LxWxD mm(inch) 90(3.60)x22.5(0.89)x114(4.49) Input-FG 1.500VAC/2121VDC min Weight 120g Insulation resistance I/O 100M min ( 500VDC) Norms and Standards Vibration resistance meet IEC 60068-2-6 CE EN 61000-6-3, EN 55022 (Mounting by rail: 10-500Hz, Class B, EN 61000-3-2, 2G, along X, Y, Z each Axis, EN 61000-3-3, 60 min for each Axis) EN 61000-6-2, EN 55024, Shock resistance meet IEC 60068-2-27 EN 61000-4-2 Level 4, (15G, 11ms, 3 Axis, 6 faces, EN 61000-4-3 Level 3, 3 times for each face) EN 61000-4-4 Level 4, UL / cUL UL508 listed, UL60950-1, EN 61000-4-5 L-Level 3, UL1310 Class 2 Power L/N-FG Level 4, (only 5V, 12V w/o Class 2) EN 61000-4-6 Level 3, Recognized, ISA 12.12.01 EN 61000-4-8 Level 4, (Class 1, Division 2, EN 61000-4-11, Groups A, B, C and D) ENV 50204 Level 2, TUV EN 60950-1, CB scheme EN 61204-3 CCC GB4943, GB9254, GB17625.1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 17/05/16 2