T t y f p e r p e a g p Switching Power Supply Type SPD 100W Bi-Phase DIN rail mounting Installation on DIN Rail 7.5 or 15mm Short circuit protection Input single phase 340 to 575VAC Passive PFC Power ready output on 24VDC LED indicator for DC power ON LED indicator for DC low Standard parallel function Very compact dimensions UL, cUL listed and TUV/CE approved Product Descrip tion Ordering Key SP D 24 100 2 This particular SPD is the and the possibility of being Model most compact 100W power used up to 70C with a little Mounting ( D = Din rail ) supply on the market. Relay derating. Furthermore it can Output voltage output for power ready be powered with 2 phases of Output power parallel function and PFC are a 3 phase grid system due to Input type included. Performances are its high voltage input. unique with high efficiencies Input type: 2= single phase high voltage (bi-phase) Approvals Rheinland Product Safety Output Performances Rated Voltage Trim Range DC ON LED (VDC) DC LO LED (VDC) Output output Output Typical 0.8 Io nom Threshold at startup Threshold after startup Model Power Voltage Current (A) Efficiency (W) Min. VDC Max. VDC Min. Max. Min. Max. (VDC) SPD12100 12 100.8 8.4 11.4 14.5 10 11.2 10 11.2 86% SPD24100 24 100.8 4.2 22.5 28.5 17.6 19.4 17.6 19.4 87% SPD48100 48 100.8 2.1 47.0 56.0 37.0 43.0 37.0 43.0 89% Output Data Output voltage accuracy -0 +1% max (factory adjusted) Rise Time Vi nom, Io nom 150ms Line regulation 1% Vi nom, Io nom with Capacitor load 500ms Load regulation Capacitor Load Non parallel model 1% 12V, 24V versions 7000F Parallel model 5% 48V version 3500F Temp. coefficient 0.03% / C Reverse Voltage Immunity Ripple and noise 50mV 12V 18V Vi nom, Io nom, BW=20MHz 24V 35V Rated continuous Loading 8.4A 12VDC / 6.9A 14.5VDC 48V 63V 4.2A 24VDC / 3.5A 28.5VDC Hold up Time Vi nom Io max 20ms 2.1A 48VDC / 1.8A 56VDC Minimum load Vi nom 0% Fall Time 150ms Parallel Operation 2 units max. Transient recovery time 0.1 Io min~0.9 Io max Vi nom, Io= 0.5 x Inom 2ms Turn On Time Vi nom, Io nom 1.0s Vi nom, Io nom with Capacitor load 1.5s 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 28/02/2017 t p r a r u o a v B e dSwitching Power Supply Type SPD 100W Bi-phase DIN rail mounting Input Data Rated input voltage 400/500VAC Frequency range 47 - 63Hz Voltage range Internal Voltage Surge Protection Varistor AC in 340 - 575VAC (acc. to IEC61000-4-5) DC in 480 - 820VDC Leakage Current Rated input current 0.48A / 0.75A Input / Output 0.25mA Input / FG 3.5mA Power dissipation 12V 15.0W Inrush current 10A 24V 13.0W P.F.C. 0.55 48V 10.5W Controls and Protections 1) Input Fuse 2A/600VAC internal Input Voltage Surge Protection Varistor Output Short Circuit current limit Power ready (only SPD241002) Threshold at start up Min. 17.6VDC - Max.19.4VDC Rated Overload Protection 115 - 135% (contact closed) Over voltage protection (auto recovery) Contact rating at 60VDC 0.3A 12V model 14.5V to 17.4V Insulation 500VDC 24V model 30.0V to 33.0V 48V model 60.0V to 66.0V 1) Fuse not replaceable by user General Data ( nominal line, full load, 25C ) Ambient temperature -25C to 71C MTBF (Bellcore Issue 6 40C), GB 12V model 622.000h Derating (>61C to +71C) 2.5% / C 24V model 661.000h Ambient humidity 20 to 95%RH 48V model 672.000h Storage -25C to +85C Altitude during operation 3.000m Pollution degree 2 Case material Plastic Protection degree IP20 Dimensions L x W x D 90 x 54 x 114mm Cooling Free air convection Weight 500g Switching frequency 45kHz Approvals and EMC Insulation voltage CE EN 61000-6-3, Input / Output 3.000VAC / 4242VDC EN 55022 Class B, Input / FG 1500VAC / 2121VDC EN 61000-3-2, EN 61000-3-3 EN 61000-6-2, EN 55024, Insulation resistance 100M min EN 61000-4-2 Level 4, Shock resistance acc. to IEC 60068-2-27 EN 61000-4-3 Level 3 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face) EN 61000-4-4 Level 4, Vibration resistance acc. to IEC 60068-2-6 EN 61000-4-5 L-N Level 3, (Mounting by rail: 10-500 Hz, 2G, along L / N-FG Level 4 X, Y, Z each Axis, 60 min for each Axis) EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, UL / cUL UL 508 Listed EN 61000-4-11 UL 60950-1 ENV 50204 Level 2, TUV EN 60950-1, EN 61204-3 CB scheme EN 61558-1, EN 61558-2-17 (acc.to EN 60204) Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 28/02/2017 2