T t y f p e r p e a g p Switching Power Supply Type SPD 10W DIN rail mounting Universal AC input full range Installation on DIN rail 7.5 or 15mm Short circuit protection Overload protection High efficiency LED indicator for DC power ON LED indication for DC low Power Ok output Internal input filter CE, TUV approved and cULus Listed Product De scrip tion Ordering Key SP D 24 10 1 B The Switching power installation is on a DIN rail Model supplies SPD series are and compact dimensions Mounting ( D = Din rail ) specially designed to be and performance are a Output voltage used in all automation must. Output power application where the Input Type Optional features Input type: 1= single phase Approvals Optional Features Rheinland Product Safety Description Code Spring connectors B Class I, Div 2 UL 1310 UL 60950-1 Output Performances INPUT OUTPUT OUTPUT OUTPUT EFF. EFF. MODEL NO. VOLTAGE WATTAGE VOLTAGE CURRENT (min.) (typ.) Single Output Models SPD05 90~264 VAC 10 WATTS + 5 VDC 2000 mA 71% 73% SPD12 90~264 VAC 10 WATTS +12 VDC 840 mA 73% 75% SPD15 90~264 VAC 10 WATTS +15 VDC 670 mA 74% 76% SPD24 90~264 VAC 10 WATTS +24 VDC 420 mA 74% 76% Output Data Line regulation 1% Rated continuous loading 5V Model 2A 5VDC/1.7A 5.75VDC Load regulation 2% 12V Model 0.84A 12VDC/0.72A 13.8VDC Minimum load 0 15V Model 0.67A 15VDC/0.58A 17.25VDC Turn on time (full resistive load) 1000ms 24V Model 0.42A 24VDC/0.34A 28.8VDC Vi nom, Io nom with 3500F 1500ms Reverse voltage 5V Model 7.5VDC Transient recovery time 2ms 12V Model 18VDC Ripple and noise 50mVpp 15V Model 22VDC Output voltage accuracy + 1% 24V Model 35VDC Temperature coefficient 0.03%/C Capacitor load 3500F Hold up time Vi= 115VAC 25ms Voltage rise time at 500ms Vi= 230VAC 100ms (full resistive load) Voltage fall time (I nom) 150ms max Vi nom, Io nom with 3500F 150ms 0 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/04/12 t p r a r u o a v B e dSwitching Power Supply Type SPD 10W DIN rail mounting Input Data Rated input voltage 100 - 240VAC Power dissipation (Vi : 230VAC, Io nom) 5V Model 4.0W Voltage range 12V Model 3.4W AC 90 - 264VAC 15V Model 3.3W DC 120 - 375VDC 24V Model 2.8W Rated input current Frequency range 47- 63Hz (Vi : 115VAC, Io nom) Typ. 200mA Max. 300mA Leakage current Input-Output 0.25mA Inrush current Input-FG 3.5mA Vi= 115VAC 10A Vi= 230VAC 18A Controls and Protections Overload 110 145% Over voltage protection 125-145% 1) Input fuse T2A/250VAC internal Internal surge voltage protection Varistor (IEC 61000-4-5) Output short circuit Hiccup mode 1) Fuse not replaceable by user General Data ( nominal line, full load, 25C ) Ambient temperature -20C to 71C MTBF (Bellcore issue 6 40C, GB) 5V Model 801000 Hours Derating (>61C to +71C) 2.5%/C 12V Model 803000 Hours Ambient humidity 20 ~ 95%RH 15V Model 805000 Hours Storage -25C to +85C 24V Model 808000 Hours Protection degree IP20 Case material Plastic: PC, UL94-V0 Cooling Free air convection Pollution degree 2 Insulation voltage Altitude 2000m Input-Output 3.000VAC/4242VDC min Dimensions LxWxD mm(inch) 90(3.60)x22.5(0,89)x114(4.49) Input-FG 1.500VAC/2121VDC min Weight 120g Insulation resistance I/O 100M min ( 500VDC) Norms and Standards Vibration resistance meet IEC 60068-2-6 CE EN 61000-6-3, EN 55022 (Mounting by rail: 10-500Hz, Class B, EN 61000-3-2, 2G, along X, Y, Z each Axis, EN 61000-3-3, 60 min for each Axis) EN 61000-6-2, EN 55024, Shock resistance meet IEC 60068-2-27 EN 61000-4-2 Level 4, (15G, 11ms, 3 Axis, 6 faces, EN 61000-4-3 Level 3, 3 times for each face) EN 61000-4-4 Level 4, UL / cUL UL508 listed, UL60950-1, EN 61000-4-5 L-Level 3, UL1310 Class 2 Power L/N-FG Level 4, Recognized, ISA 12.12.01 EN 61000-4-6 Level 3, (Class 1, Division 2, EN 61000-4-8 Level 4, Groups A, B, C and D) EN 61000-4-11, TUV EN 60950-1, CB scheme ENV 50204 Level 2, EN 61204-3 CCC GB4943, GB9254, GB17625.1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/04/12 2