T t y f p e r p e a g p Switching Power Supply Type SPD 120W 3 phases DIN rail mounting Universal AC 3 phases input full range Can also be used as single phase 480VAC Installation on DIN rail 7.5 or 15mm PFC as standard High efficiency up to 88% Power ready output Compact dimensions UL, cUL listed and TUV/CE Product De scrip tion Ordering Key SP D 24 120 3 The Switching power installation is on a DIN rail Model supplies SPD series are and compact dimensions Mounting (D= Din rail) specially designed to be and performance are a must. Output voltage used in all automation Output power application where the Input Type Input type: 3 = three phase Approvals 3) (or single phase 400/500VAC ) Rheinland Product Safety Output performances INPUT OUTPUT OUTPUT OUTPUT EFF. EFF. MODEL NO. VOLTAGE WATTAGE VOLTAGE CURRENT (min.) (typ.) Single Output Models 3 340~575 VAC 120 WATTS + 12 VDC 10 A 85% 87% SPD12 SPD24 3 340~575 VAC 120 WATTS + 24 VDC 5 A 87% 89% Output data Line regulation 1% Voltage fall time (I nom) 150ms max 0 Load regulation 1% Rated continuous loading 12V Model 10A 12VDC/8.2A 14.5VDC Minimum load 0 24V Model 5A 24VDC/4.2A 28.5VDC Turn on time (full resistive load) Reverse voltage Vi nom, Io nom 150ms 12V Model 18VDC Vi nom, Io nom 24V Model 35VDC 12v model with 7000F CAP 500ms Vi nom, Io nom Capacitor load 24v model with 3500F CAP 500ms Vi nom Io nom 12V model 7000F Vi nom Io nom 24V model 3500F Transient recovery time 2ms Voltage rise time Ripple and noise 100mVpp Vi nom Io nom 150ms Output voltage accuracy 1% Vi nom, Io nom 12v model with 7000F CAP 500ms Temperature coefficient 0.03%/C Vi nom, Io nom Hold up time 20ms 24v model with 3500F CAP 500ms 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/04/12 t p r a r u o a v B e dSwitching Power Supply Type SPD 120W 3 phases DIN rail mounting Input data Rated input voltage 400 - 500VAC Power dissipation 12V Model 20W Voltage range 24V Model 16W AC 340 - 575VAC DC 480 - 820VDC Frequency range 47- 63Hz Rated input current Leakage current (Vi : 400VAC, Io nom) Typ. 0.36A Input-Output 0.25mA Max. 0.5A Input-FG 3.5mA Inrush current Vi nom, Io nom 10A Controls and Protections Overload 115-135% Over voltage protection VDC 1) Min. Max. Input fuse T2A/600VAC internal 12V Model 14.5 17.4 Output short circuit Hiccup mode 24V Model 30 33 Power ready output Internal surge voltage protection Varistor (only 24V model) On threshold 17.6 -19.4VDC (IEC 61000-4-5) Elettrical isolation 500VDC Contact rating at 60vdc 0.3A 1) Fuse not replaceable by user General data ( nominal line, full load, 25C ) Ambient temperature -35C to 71C MTBF (Bellcore issue 6 40C, GB) 12V Model 527000 Hours Derating (>61C to +71C) 2.5%/C 24V Model 559000 Hours Ambient humidity 20 ~ 90%RH Case material Metal Storage -25C to +85C Dimensions LxWxD mm(inch) 124(4.88) x 74.3(2.92) x 118.8(4.68) Protection degree IP20 Weight 800g Cooling Free air convection Pollution degree 2 Norms and Standards Vibration resistance meet IEC 60068-2-6 CCC GB4943, GB9254, GB17625.1 (Mounting by rail: 10-500Hz, CE EN 61000-6-3, EN 55022 2G, along X, Y, Z each Axis, Class B, EN 61000-3-2, 60 min for each Axis) EN 61000-3-3, Shock resistance meet IEC 60068-2-27 EN 61000-6-2, (15G, 11ms, 3 Axis, 6 faces, EN 55024, EN 61000-4-2 3 times for each face) Level 4, EN 61000-4-3 Level 3, EN 61000-4-4 UL / cUL UL508 listed, UL60950-1, Level 4, EN 61000-4-5 L- Recognized, ISA 12.12.01 Level 3, L/N-FG Level 4, (Class 1, Division 2, EN 61000-4-6 Level 3, Groups A, B, C and D) EN 61000-4-8 Level 4, TUV EN 60950-1, CB scheme EN 61000-4-11, EN 61558-1, EN 61558-2-17 ENV 50204 Level 2, (meet EN 60204) EN 61204-3 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/04/12 2