T t y f p e r p e a g p Switching Power Supply Type SPD 240W 3 phases DIN rail mounting Universal AC 3 phases input full range Installation on DIN rail 7.5 or 15mm PFC as standard High efficiency up to 90% Power ready output Parallel connection feature Compact dimensions UL, cUL listed and TUV/CE Product Description Ordering Key SP D 24 240 3 The Switching power application where the Model supplies SPD series are installation is on a DIN rail Mounting (D= Din rail) specially designed to be and compact dimensions Output voltage used in all automation and performance are a must. Output power Input Type Input type: 3 = three phase Approvals Rheinland Product Safety Output Performances INPUT OUTPUT OUTPUT OUTPUT EFF. EFF. MODEL NO. VOLTAGE WATTAGE VOLTAGE CURRENT (min.) (typ.) Single Output Models SPD24 3 340~575 VAC 240 WATTS +24 VDC 10 A 85% 90% SPD48 3 340~575 VAC 240 WATTS +48 VDC 5 A 89% 91% Output Data Line regulation 1% Voltage fall time (I nom) 150ms max 0 Load regulation Rated continuous loading Single mode 1% 24V Model 10A 24VDC/8.2A 28.5VDC Parallel mode 5% 48V Model 5A 48VDC/4.2A 56VDC When S/P switch is set to parallel, Reverse voltage it is not possible to trim output voltage. 12V Model 35VDC Minimum load 0A 24V Model 63VDC Turn on time (full resistive load) Capacitor load VI nom, Io nom 1000ms Vi nom Io nom 24V model 7000F VI nom, Io nom 12V model Voltage rise time with 7000 F CAP 1500ms Vi nom Io nom 150ms Transient recovery time 2ms Vi nom, Io nom Ripple and noise 100mVpp 12V model with 7000F CAP 500ms Output voltage accuracy 1% Temperature coefficient 0.03%/C Hold up time Vi 20ms 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 17/11/2017 t p r a r u o a v B e dSwitching Power Supply Type SPD 240W 3 phases DIN rail mounting Input Data Rated input voltage 400 - 500VAC Inrush current Voltage range Vi nom, Io nom Typ. 20A AC 3PH AC IN 340 - 575Vac Max. 25A 47-63Hz Inrush current time 2PH AC IN 340 - 575Vac Vi nom, Io nom 4 ~ 6 ms 47-63Hz (with 2P the Power dissipation output is derated to 75%) 24V Model 30W DC 480 - 820VDC 48V Model 24W Input current Frequency range 47-63Hz (Vi: 400VAC / 500VAC, Io nom) Leakage current Typ. 0.65A / 0.55A Input-Output 0.25mA Rated input current Input-FG 3.5mA (Vi: 340VAC, Io nom) Max. 0.85A Controls and Protections 1) Input fuse 2A/600VAC internal/Phase Over voltage protection VDC Output short circuit Hiccup mode Min. Max. Power ready output 24V Model 30 33 (only 24V model) on threshold 17.6-19.4VDC 48V Model 60 68 Electrical isolation 500VDC Internal surge voltage protection Varistor (IEC 61000-4-5) Contact rating at 60VDC 0.3A 1) Fuse not replaceable by user General Data ( nominal line, full load, 25C) Ambient temperature -40C to +71C MTB (Bellcore issue 6 40C, GB) Derating (>61C to +71C) 2.5%/C 24V Model 488000 Hours Ambient humidity 20 ~ 90% RH 48V Model 519000 Hours Storage -25C to +85C Case material Metal Protection degree IP20 Dimensions LxWxD mm(inch) 124 (4.88) x 89 (3.5) x 118.8 (4.68) Cooling Free air convection Weight 1100 g Pollution degree 2 Norms and Standards Vibration resistance meet IEC 60068-2-6 CQC GB4943.1-2011, (Mounting by rail: 10-500Hz, GB9254-2008, 2G, along X, Y, Z each Axis, GB17625.1-2012 60 min for each Axis) CE EN 61000-6-3, EN 55022 Shock resistance meet IEC 60068-2-27 Class B, EN 61000-3-2, (15G,11ms, 3 Axis, 6 faces, EN 61000-3-3, EN 61000-6-2, 3 times for each face) EN 55024, EN 61000-4-2 UL/cUL UL508 listed, UL60950-1, Level 4, EN 61000-4-3 Recognized, ISA 12.12.01 Level 3, EN 61000-4-4 (Class 1, Division 2, Groups Level 4, EN 61000-4-5 Level 3, A, B, C and D) L/N-FG Level 4, EN 61000-4-6 TUV EN 60950-1, CB scheme Level 3, EN 61000-4-8 Level 4, EN 61558-1, EN 61558-2- EN 61000-4-11, ENV 50204 17 (meet EN 60204) Level 2, EN 61204-3 2 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 17/11/2017