T t y f p e r p e a g p Switching Power Supply Type SPD 480W 3 phases DIN rail mounting Universal AC 3 phases input full range Can also be used as single phase 480VAC Installation on DIN rail 7.5 or 15mm PFC as standard High efficiency up to 91% Power ready output Parallel connection feature Compact dimensions UL, cUL listed and TUV/CE Product De scrip tion Ordering Key SP D 24 480 3 The Switching power installation is on a DIN rail Model supplies SPD series are and compact dimensions Mounting (D= Din rail) specially designed to be and performance are a must. Output voltage used in all automation Output power application where the Input Type Input type: 3 = three phase 3) Approvals (or single phase 400/500VAC ) Rheinland Product Safety Output performances INPUT OUTPUT OUTPUT OUTPUT EFF. EFF. MODEL NO. VOLTAGE WATTAGE VOLTAGE CURRENT (min.) (typ.) Single Output Models SPD24 3 340~575 VAC 480 WATTS + 24 VDC 20 A 88% 90% SPD48 3 340~575 VAC 480 WATTS + 48 VDC 10 A 89% 91% Output data Line regulation 1% Voltage fall time (I nom) 150ms max 0 Load regulation Rated continuous loading Single mode 1% 24V Model 20A 24VDC/16.8A 28.5VDC Parallel mode 5% 48V Model 10A 48VDC/8.5A 56VDC Minimum load 0 Reverse voltage 24V Model 35VDC Turn on time (full resistive load) 48V Model 63VDC Vi nom, Io nom 1000ms Vi nom, Io nom Capacitor load with 7000F CAP 1500ms Vi nom Io nom 24V model 7000F Voltage rise time Transient recovery time 2ms Vi nom Io nom 150ms Ripple and noise 100mVpp Vi nom, Io nom with 7000F CAP 500ms Output voltage accuracy 1% Temperature coefficient 0.03%/C Hold up timeVi 20ms 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 15/07/15 t p r a r u o a v B e dSwitching Power Supply Type SPD 480W 3 phases DIN rail mounting Input data Rated input voltage 400 - 500VAC Power dissipation 24V Model 58W Voltage range 48V Model 55W AC 340 - 575VAC DC 480 - 820VDC Frequency range 47- 63Hz Rated input current Leakage current (Vi : 400VAC, Io nom) Typ. 1.1A Input-Output 0.25mA Max. 1.4A Input-FG 3.5mA Inrush current Vi= 115VAC 20A Controls and Protections Overload 110-135% Elettrical isolation 500VDC Contact rating at 60vdc 0.3A Input fuse T3.15A/500VAC internal phase Over voltage protection VDC Output short circuit Min. Max. Continuos Fold forward 24V Model 30 33 Discontinuos Delay 3S shut-down. After 48V Model 60 68 30S auto restart Internal surge voltage protection Varistor Power ready output (IEC 61000-4-5) (only 24V model) On threshold 17.6 -19.4VDC 1) Fuse not replaceable by user General data ( nominal line, full load, 25C ) Ambient temperature -30C to 71C MTBF (Bellcore issue 6 40C, GB) 24V Model 411000 Hours Derating (>61C to +71C) 2.5%/C 48V Model 423000 Hours Ambient humidity 20 ~ 90%RH Case material Metal Storage -40C to +85C Dimensions LxWxD mm(inch) 124(4.88) x 150(5.91) x 118.8(4.68) Protection degree IP20 Weight 1720g Cooling Free air convection Pollution degree 2 Norms and Standards Vibration resistance meet IEC 60068-2-6 CCC GB4943, GB9254, GB17625.1 (Mounting by rail: 10-500Hz, CE EN 61000-6-3, EN 55022 2G, along X, Y, Z each Axis, Class B, EN 61000-3-2, 60 min for each Axis) EN 61000-3-3, Shock resistance meet IEC 60068-2-27 EN 61000-6-2, (15G, 11ms, 3 Axis, 6 faces, EN 55024, EN 61000-4-2 3 times for each face) Level 4, EN 61000-4-3 Level 3, EN 61000-4-4 UL / cUL UL508 listed, UL60950-1, Level 4, EN 61000-4-5 L- Recognized, ISA 12.12.01 Level 3, L/N-FG Level 4, (Class 1, Division 2, EN 61000-4-6 Level 3, Groups A, B, C and D) EN 61000-4-8 Level 4, TUV EN 60950-1, CB scheme EN 61000-4-11, EN 61558-1, EN 61558-2-17 ENV 50204 Level 2, (meet EN 60204) EN 61204-3 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 15/07/15 2