T t y f p e r p e a g p Switching Power Supply Type PSS 480W DIN rail mounting Universal AC single phase input full range Can also be used as bi-phase 400VAC Installation on DIN rail 7.5 or 15mm PFC as standard High efficiency up to 90% Power ready output Parallel connection feature Compact dimensions CE, TV, CCC approved and cULus listed Class I Div 2 Groups A, B, C, D approved Product Description Ordering Key SP D 24 480 1 B The Switching power application where the Model supplies SPD series are installation is on a DIN rail Mounting ( D = Din rail ) specially designed to be and compact dimensions Output voltage used in all automation and performance are a must. Output power Input type Optional features Input type: 1= single phase Approvals Optional Features Description Code Plug-in connectors B Rheinland Product Safety Output Performances INPUT OUTPUT OUTPUT OUTPUT EFF. EFF. MODEL NO. VOLTAGE WATTAGE VOLTAGE CURRENT (min.) (typ.) Single Output Models SPD24 90~264 VAC 480 WATTS + 24 VDC 20 A 86% 89% SPD48 90~264 VAC 480 WATTS + 48 VDC 10 A 87% 90% 1) When S/P switch is set to parallel, it is not possible to trim output voltage. Output Data Line regulation 0.5% Hold up time Load regulation Vi= 115VAC 25ms Non parallel model 1% Vi=230VAC 30ms Parallel model 5% Voltage fall time (I nom Vi nom) 150ms max 0 Minimum load 0A Rated continuous loading Turn on time (full resistive load) 24V Model 20A 24VDC/16.8A 28.5VDC VI nom, Io nom 1000ms 48V Model 2.1A 48VDC/8.5A 56VDC VI nom, Io nom with 7000 F CAP 1500ms Reverse voltage Transient recovery time 2ms 24V Model VDC 35 Ripple and noise 100mVpp 48V Model VDC 63 Output voltage accuracy 1% Capacitor load 7000F Temperature coefficient 0.03%/C Voltage rise time Vi nom Io nom 150ms Vi nom, Io nom with 7000F CAP 500ms 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 17/11/2017 t p r a r u o a v B e dSwitching Power Supply Type SPD 480W DIN rail mounting Input Data Rated input voltage 115 - 230VAC Power dissipation Voltage range (Vi : 400VAC, Io nom) 24V Model 63W AC 90 - 264VAC 48V Model 56W DC 120 - 375VDC Frequency range 47-63Hz Rated input current Leakage current (Vi:90VAC, Io nom) Typ. 4.9/2.5A Input-Output 0.25mA Max. 7/3.5A Input-FG 3.5mA Inrush current P.F.C Vi=115/230VAC, Ionom 0.99/0.97 Vi= 115VAC 25A Vi= 230VAC 50A Controls and Protections Overload 110 - 140% Over voltage protection 125/140% Input fuse T10A/250VAC internal Internal surge voltage protection Varistor (IEC 61000-4-5) Output short circuit Fold forward Power ready output threshold at start up 17.6-19.4VDC Electrical isolation 500VDC Contact rating at 60VDC 0.3A General Data ( nominal line, full load, 25C) Ambient temperature -40C to +71C Case material Metal Derating (>61C to +71C) 2.5%/C Dimensions LxWxD mm (inch) Ambient humidity 20 ~ 95%RH Screw terminal type 124.5 x 175.5 x 123.6 mm Storage -40C to +85C (4.9 x 6.91 x 4.87 inches) Protection degree IP20 Detachable connector type 143.5 x 175.5 x 123.6 mm Cooling Free air convection (5.65 x 6.91 x 4.87 inches) Pollution degree 2 Weight 430 g MTB (Bellcore issue 6 40C, GB) 24V Model 403000 Hours 48V Model 416000 Hours Norms and Standards Vibration resistance meet IEC 60068-2-6 CE EN 61000-6-3, EN 55022 (Mounting by rail: 10-500Hz, Class B, EN 61000-3-2, 2G, along X, Y, Z each Axis, EN 61000-3-3, 60 min for each Axis) EN 61000-6-2, Shock resistance meet IEC 60068-2-27 EN 55024, (15G,11ms, 3 Axis, 6 faces, EN 61000-4-2 Level 4, 3 times for each face) EN 61000-4-3 Level 3, UL/cUL UL508 listed, UL60950-1 EN 61000-4-4 Level 4, Recognized EN 61000-4-5 L-Level 3, TUV EN 60950-1, CB scheme L/N-FG Level 4, EN 61558-1, EN 61558-2- EN 61000-4-6 Level 3, 17 (meet EN 60204) EN 61000-4-8 Level 4, ISA 12.12.01 Class I Div 2 EN 61000-4-11, Groups A, B, C, D ENV 50204 Level 2, EN 61204-3 2 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 17/11/2017