T t y f p e r p e a g p Switching Power Supply Type SPD 60W DIN rail mounting Universal AC input full range Installation on DIN rail 7.5 or 15mm Short circuit protection Overload protection Class 2 output High efficiency LED indicator for DC power ON Power Ok output CE, TUV approved and cULus Listed Product De scrip tion Ordering Key SP D 24 60 1 B The Switching power supplies and compact dimensions and Model SPD series are specially performance are a must. Mounting ( D = Din rail ) designed to be used in all Output voltage automation application where Output power the installation is on a DIN rail Input Type Optional features Input type: 1= single phase Approvals Optional Features Description Code Rheinland Product Safety Spring connectors B Output Performances DC ON green LED at start up Rated output Output Output Voltage Trim Range Typical Model DC LOW red LED after start up Voltage (VDC) Power (W) Current (A) Efficiency Min. VDC Max. VDC Min. VDC Max. VDC SPD05 5 50 10.0 5 5.5 3.5 4.5 79% 12 60 5.0 12 14 9.0 10.8 86% SPD12 SPD24 24 60 2.5 24 28 18 21.6 89% SPD48 48 60 1.25 48 55 37 43 89% Output Data Line regulation 0.5% Rated continuous loading 5V Model 10A 5VDC/9.0A 5.5VDC Load regulation 0.5% 12V Model 5A 12VDC/4.25A 14VDC Minimum load (A) 0 24V Model 2.5A 24VDC/2.1A 28VDC Turn on time (full resistive load) 1000ms max 48V Model 1.25A 48VDC/1.08A 55VDC Transient recovery time 2ms Reverse voltage 5V Model 7.5VDC Ripple and noise 50mVpp 12V Model 18VDC Output voltage accuracy 1% 24V Model 35VDC Temperature coefficient 0.03%/C 48V Model 63VDC Hold up time Vi= 115VAC 20ms Capacitor load 7000F Vi= 230VAC 30ms Voltage rise time at 150ms max Voltage fall time (I nom) 150ms max 0 full resistive load 10/01/19 Specifications are subject to change without notice, Pictures are just an example. For special features and/or customisation, please ask our sales network. 1 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/04/12 t p r a r u o a v B e dSwitching Power Supply Type SPD 60W DIN rail mounting Input Data Rated input voltage 100 - 240VAC Power dissipation (Vi : 230VAC, Io nom) 5V Model 12.5W Voltage range 12V Model 9.0W AC 85 - 264VAC 24V Model 8.8W DC 90 - 375VDC 48V Model 7.8W Rated input current Frequency range 47- 63Hz (Vi : 115VAC, Io nom) Typ. 1060mA Max. 1500mA Leakage current Input-Output 0.25mA Inrush current Input-FG 3.5mA Vi= 115VAC 20A Vi= 230VAC 40A Controls and Protections Overload 110 150% Over voltage protection VDC 1) Min. Max. Input fuse T2A/250VAC internal 5V Model 6.0 6.8 Output short circuit Fold forward 12V Model 15 16.5 Power ready output (Rdy) 24V Model 30 33 (only SPD 24) On threshold Vout > 19,2V 2% 48V Model 60 66 Off threshold Vout < 19,1V 2% Internal surge voltage protection Varistor (IEC 61000-4-5) 1) Fuse not replaceable by user General Data ( nominal line, full load, 25C ) Ambient temperature -40C to 71C MTBF (Bellcore issue 6 40C, GB) 5V Model 498000 Hours Derating (>61C to +71C) 2.5%/C 12V Model 504000 Hours Ambient humidity 20 ~ 95%RH 24V Model 520000 Hours Storage -40C to +85C 48V Model 531000 Hours Protection degree IP20 Case material Plastic: PC, UL94-V0 Cooling Free air convection Pollution degree 2 Insulation voltage Altitude 2000m Input-Output 3.000VAC/4242VDC min Dimensions LxWxD mm(inch) 90(3.60)x40.5(1.59)x114(4.49) Input-FG 1.500VAC/2121VDC min Weight 340g Insulation resistance I/O 100M min ( 500VDC) Norms and Standards Vibration resistance meet IEC 60068-2-6 CE EN 61000-6-3, EN 55022 (Mounting by rail: 10-500Hz, Class B, EN 61000-3-2, 2G, along X, Y, Z each Axis, EN 61000-3-3, 60 min for each Axis) EN 61000-6-2, EN 55024, Shock resistance meet IEC 60068-2-27 EN 61000-4-2 Level 4, (15G, 11ms, 3 Axis, 6 faces, EN 61000-4-3 Level 3, 3 times for each face) EN 61000-4-4 Level 4, UL / cUL UL508 listed, UL60950-1, EN 61000-4-5 L-Level 3, UL1310 Class 2 Power L/N-FG Level 4, (only 5V, 12V w/o Class 2) EN 61000-4-6 Level 3, Recognized, ISA 12.12.01 EN 61000-4-8 Level 4, (Class 1, Division 2, EN 61000-4-11, Groups A, B, C and D) ENV 50204 Level 2, TUV EN 60950-1, CB scheme EN 61204-3 EN 61558-1, EN 61558-2-17 (meet EN 60204) CCC Available upon request CCC GB4943, GB9254, GB17625.1 2 SpecificaSpecifications are subject to change without noticetions are subject to change without notice. Pictures are just an example., Pictures are just an example For special fea. For special features and/or customisation,tures and/or customization, p please ask our sales network.lease ask to our sales network. 18/04/12 10/01/192