T t y f p e r p e a g p Modular Switching Power Supply Type SPM 1 DIN rail mounting Single DIN module Universal input 90/264VAC 120/370VDC High efficiency up to 80% Short circuit protection Overload protection Internal input filter LOW voltage LED indicator UL Class 2 Output Product Description Ordering Key SPM 1 - 24 1 SPM Modular switching requirements. The single Series power supplies are DIN module PS is capable Number of DIN modules specifically designed in of up to 10W of output Output Voltage order to satisfy both the power. Its high efficiency Phases (only single phase) Automation and the Building prevents excess of heat in automation application the installation place. Approvals Rheinland Product Safety Class 2 Output performances Model Input Output Output Current Typical Voltage Power Voltage Efficiency SPM1-051 90~264Vac 7.5W 5Vdc 1.50A 74% SPM1-121 90~264Vac 10W 12Vdc 0.83A 78% SPM1-151 90~264Vac 10W 15Vdc 0.67A 78% SPM1-241 90~264Vac 10W 24Vdc 0.42A 80% Output data Line regulation 1% max. DC ON indicator Min. Max. Load regulation 1% 5V 3Vdc - Output Voltage accuracy 1% 12V 9Vdc - Ripple and Noise 50mV 15V 11Vdc - Temperature Coefficient 0.02%/C (0.0112%/F) 24V 20Vdc - Hold up time Vi = 115Vac 5V and 12V: 10ms DC LOW indicator Min. Max. 15V and 24V: 60ms 5V 3.2Vdc 3.7Vdc Vi = 230Vac 30ms 12V 8.8Vdc 9.3Vdc Minimum load 0% 15V 12Vdc 12.5Vdc Transient recovery time 24V 21.5Vdc 22Vdc (50% load step changed) 1ms Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 1 t p r a r u o a v B e dModular Switching Power Supply Type SPM 1 DIN rail mounting Input data Controls and Protections Rated input voltage 100/240VAC Input Fuse T1A/250Vac internal* Voltage range Output Short Circuit Fold forward AC in 90 - 264 Vac Rated Overload Protection 110-160% DC in 120 - 370 Vdc Line frequency 47 - 63Hz Inrush current Vi= 115Vac Typ: 10A Max: 15A Vi= 230Vac Typ: 20A Max: 30A * Not replaceable by user General data ( nominal line, full load, 25C ) Insulation voltage 3.000Vac Cooling Free air convection Insulation resistance 100M Case material Plastic (PC-UL94-V0) Ambient temperature -25Cto+71C(-13Fto159.8F) Weight 60g Derating (>61C to +71C) 2.5%/C (1.4%F) Protection degree IP20 Ambient humidity 90%RH Storage temperature -25C to +85C (-13F to 185F) Dimensions L x W x D mm 91 x 18 x 55.5 L x W x D inches 3.582 x 0.709 x 2.185 Approvals UL / cUL file: E258355 UL508 listed, CE EN61000-6-3, file: E258395 UL1310 Class 2 power supply, EN55022 class B, file: E258396 UL60950-1 Recognized EN61000-3-2, EN61000-3-3, TUV EN60950-1 EN61000-6-2, EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11 Block diagrams L Fuse Vo+ InrushCurrent Line Switching Limiter and Rectifier Filter Device rectifier N Vo- Control circuit Opto- Reference& Error Amp. Isolation Vout ADJ. Opto- Over Voltage Detection Isolation DCON Output Level (GreenLED) Detection DCLO (RedLED) 2 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network