Smart Power Supply and UPS Type SPUBC 24V 5A Single phase input 115Vac / 230Vac / 277Vac Smart power management Rated output 5A with permanent 10A overboost Max battery charging current 5A Suitable for Lead Acid open or sealed, Lead gel Automatic Battery diagnostic and battery care Boost, Trikle/float and recovery charging cycles. Battery reversed polarity, element short circuit or disconnection 2 relay outputs for remote status and operation indication cURus recognized and CE approved Product Description The new Carlo Gavazzi regardless of the setting. battery faults such as battery By means of built in jumpers SPUBC puts you in the On the SPUBC24120 the sulphatation, elements in it is possible to set preset driving seat of your power rated output current is short circuit, accidental curves. management requirements, 5A, although, after the reverse polarity connection They are programmed for allocating power, in the most battery is charged, the and battery disconnection two charging levels, boost efficient way, between the power supply can provide or bad connection. All these and float/trikle, but can be load and the battery.The 10A. SPUBC implements can be easily detected and changed to single charging maximum available current a comprehensive process removed during installation level by the user. for battery charging is set by called Battery Care and operation by the In addition to the SPUBC, means of a front trimmer. It that applies algorithms to diagnostic LED Blinking Carlo Gavazzi, also provides can go from 20% to 100%, obtain rapid and automatic Code. Continuous battery a selection of Racks for DIN which means that it possible charging, battery charge efficiency monitoring, rail mounting of the battery, to charge with up to 5A. The optimization over time, reduces battery damage risk with battery included upon priority though is always the flat battery recovery and and allows safe operation in request from 1.2Ah up to load. If the load requires real time diagnostic during permanent connection. 12Ah capable of providing, 80% of current, the current installation and operation. This device is suitable for a depending upon load, from a available for the battery is The Real Time auto- selection of most common few minutes to several hours only the remaining 20% diagnostic system, monitors battery types. of charge reserve. Approvals Ordering Key SPUBC 24 120 Power supply UPS battery charger Battery and Output Voltage Vdc Output power W Output Data Power dissipation Max. Load 17W Output voltage 24Vdc Short circuit protection Yes Nominal current 5A Over load protection Yes Rated output current 5A Overvoltage output protection Yes (typ. 35Vdc) Efficiency Thermal protection Yes ( 50% of rated current) 90% Turn on delay 1S (Max) Max Capacitive load startup Unlimited 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 17/06/2015Smart Power Supply and UPS Type SPUBC 24V 5A Input Data Nominal input voltage 115 ~ 230 ~ 277Vac Frequency 47 63Hz Voltage range 90 305Vac Input current (115 - 230Vac) 2.8 ~ 1.3A Inrush current Internal fuse (not replaceable) 4A 2 (Vn - In nom. Load) I t 11A 5ms External fuse MCB curve B 10A General Data Insulation voltage Dimensions W x H x D 65 x 115 x 135mm IN / OUT 3000Vac Weight 0.6Kg approx. IN / GND 1605Vac Operating temperature -25C ~ 70C a OUT / GND 500Vac Derating T >50C -2.5% (In)/C Protection Degree Storage temperature -40C ~ +85C EN/IEC 60529 IP20 Ambient Humidity RH 95% Pollution degree 2 not condensing Connection wires size 2.5mm (24-14AWG) Cooling Natural air flow, convection Protection class I (IEC61140) (with PE connected) Battery Charger ( 25C Ambient, Inom) Charging current Adjustment 20 ~ 100% Inom Boost charge 28.8Vdc Reverse battery protection Yes Max. Boost charge duration 15h Sulfated battery check Yes Min. duration boost charge 1min. Trickle charge 27.5Vdc Detection of battery element MTBF IEC 61709 > 300.000h in short circuit Yes Quiescent current 5mA Recovery charge 2 ~ 16Vdc Charging Profile 3 stage Max. Charging current 5A 5% Remote input control Boost / Trickle Power Supply Output ( 25C Ambient, Inom) Max current output load 15A x 4s Max Output voltage 22 ~ 28.8Vdc Total discharge protection 19 ~ 20Vdc batt Output Current 1.1 x I 5% n A Flat battery alarm 20 ~ 21Vdc batt Continuos current (without battery) 5A Continuos current (with battery) 10A Signal Outputs Mains or backup power Yes Relay outputs Low battery Yes Type 2 x SPDT Battery fault Yes Max. AC Load AC1 1A 60Vac Max. DC Load DC1 1A 30Vdc Min. Load 1mA 5Vdc Signal Port RJ45 (RJ 45 Auxiliary Output behind the label remove the window label to find the connector) Battery temp. Compensation Yes. It is possible connect a Can Bus No temperature sensor, for ambient temperature charging compensation. Remote monitoring display Yes. It is possible connect an external display to remote N 3 led of the internal device. 2 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 17/06/2015