Industrial Cord Cord & Cordset Super Vu-Tron Single Conductor 90C (UL), Type W, 2000 Volt and Types RHH/RHW 600 Volt Portable Power Cable Product Construction: Conductor: 8 AWG through 500 kcmil fully annealed stranded bare copper Insulation: Premium-grade 90C EPDM Jacket: Super Vu-Tron 90C, black Temperature range: -40C to +90C TYPE W 2000 VOLT (UL) AND TYPE RHH/RHW 600 VOLT (UL) Voltage rating: 600 volts Type RHH/RHW APPROX. NOMINAL NOMINAL INS. CURRENT 2000 volts Type W NO. AWG NET WT. COND. O.D. THICKNESS NOMINAL O.D. AMPS An open polyester braid reinforcement is applied CATALOG OF OR COND. LBS/ (S) between the insulation and jacket for mechanical NUMBER COND. kcmil STRAND INCHES mm INCHES mm INCHES mm (1) (2) M strength 83008* 1 8 133 0.160 4.06 0.060 1.52 0.470 11.94 55 80 145 Jacket Marking: 8-1 AWG: CAROL SUPER VU-TRON TYPE 83006 1 6 259 0.198 5.03 0.060 1.52 0.545 13.84 75 105 205 W PORTABLE POWER CABLE (UL) DRY 90C WET 75C 2000 V SUNLIGHT RESISTANT P-7K- 83004 1 4 259 0.245 6.22 0.060 1.52 0.595 15.11 95 140 270 123049-MSHA (SIZE) TYPE RHH OR RHW (UL) 600 V MADE IN USA 83002 1 2 259 0.294 7.47 0.060 1.52 0.670 17.02 130 190 380 1/0-500 kcmil: CAROL SUPER VU-TRON TYPE 83001 1 1 259 0.346 8.79 0.080 2.03 0.730 18.54 150 220 465 W PORTABLE POWER CABLE (UL) DRY 90C WET 75C 2000 V SUNLIGHT RESISTANT P-7K- 83010 1 1/0 259 0.384 9.75 0.080 2.03 0.790 20.07 170 260 550 123049-MSHA (SIZE) TYPE RHH OR RHW (UL) 600 V FOR CT USE --- CSA TYPE W (-40C) 83020 1 2/0 259 0.441 11.20 0.080 2.03 0.865 21.97 195 300 675 2 KV FT5 MADE IN USA 83030 1 3/0 259 0.482 12.24 0.080 2.03 0.910 23.11 225 350 790 Applications: Portable power systems 83040 1 4/0 259 0.555 14.10 0.080 2.03 0.960 24.38 260 405 940 Entertainment industry activities such as theatre, 83250 1 250 627 0.615 15.62 0.105 2.67 1.045 26.54 290 455 1125 television, night clubs, motion pictures, mobile communication vans, spotlights and sound 83350 1 350 855 0.725 18.42 0.105 2.67 1.145 29.08 350 570 1465 systems Other similar applications that would require 83500 1 500 1235 0.880 22.35 0.105 2.67 1.315 33.40 430 700 2010 permanent or temporary power Permanent wiring of 600 volt power supplies, * Non-stock item minimum quantity purchase required. hoists, cranes and other applications where (1) Ampacities based on 90C conductor and 30C ambient temperature based on Table 310.15(B)(16) in the National flexible power leads must be installed in conduit Electrical Code for RHH/RHW with not more than three current-carrying conductors in raceway, cable or earth. (2) or raceways Ampacities based on 90C conductor and 30C ambient temperature based on Table 310.15(B)(17) and Table 400.5(A)(2) in the National Electrical Code for single-conductor cables. Features: (S) Actual shipping weight may vary. Water-resistant* Designated for CT use. Sunlight-resistant Designed to withstand severe environmental conditions Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals Meets or exceeds flame test requirements of MSHA and UL Industry Approvals: UL Type W UL Type RHH or RHW MSHA Approved RoHS Compliant Packaging: Lengths cut to order * Suitable for immersion in water if properly sealed and terminated. 35X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for carol manufacturer: Other Similar products are found below : 01364.35T.01 C1321.41.01 C2015A.12.04 C4066A.38.10 01104.99.01 01343.35T.01 02728-85-01 5133290E 2133016 16065.41.01 5131431E 09814.99.01 E2206S.41.86 E1524S.41.03 E2534S.41.03 C2016A.12.03 C2064A.12.02 C0570A.41.10 C1343A.41.10 C1357.41.90 C2405A.41.10 C1352A.41.10 C2536A.38.10 C1361.38.90 E2204S.41.02 E3612S.41.03 E1032S.25.10 02604.41T.05 02605.41T.05 02608.41T.05 02632.35T.05 02634.41T.05 02601.41T.05 01360.35T.01 01342.35T.01 C-8002-12 01380.35T.01 01774.35T.01 5133274E C2040A.21.03 C2104A.12.06 C1302.41.01 E2032S.41.10 E2242S.41.86 E1502S.25.03 E2004S.18.10 02601.35T.05 02602.35T.05 02635.35T.05 06200.61.06L