V13 DIN RAIL Series 40/60/100 Watt Single Output Features * Universal Input Range 90~264VAC * Efficiency up to 90% * Meets EN55022 and CISPR/FCC Class B * Continuous Short Circuit Protection * LED Indicator for Power ON * Can be Installed on DIN rail TS-35/7.5 or 15 CFM40CXXX-DR Series OUTPUT RIPPLE & VOLTAGE OUTPUT % EFF. LINE LOAD MODEL VOLTAGE NOISE ACCURACY REGULATION REGULATION (Typ.) CURRENT CFM40C033-DR 3.3 V 6 A 50mV 70% 1% 0.5% 1% CFM40C050-DR 5 V 6 A 1% 1% 0.5% 1% 76% CFM40C090-DR 9 V 4.45 A 1% 1% 0.5% 1% 84% CFM40C120-DR 12 V 3.34 A 1% 85% 1% 0.5% 1% CFM40C150-DR 15 V 2.67 A 1% 85% 1% 0.5% 1% CFM40C240-DR 24 V 1.67 A 1% 85% 1% 0.5% 1% CFM40C300-DR 30 V 1.33 A 1% 1% 0.5% 1% 86% CFM40C360-DR 36 V 1.11 A 1% 1% 0.5% 1% 87% CFM40C480-DR 48 V 0.834 A 1% 87% 1% 0.5% 1% CFM60CXXX-DR Series OUTPUT RIPPLE & VOLTAGE LINE LOAD OUTPUT % EFF. MODEL VOLTAGE NOISE ACCURACY REGULATION REGULATION (Typ.) CURRENT 72% CFM60C033-DR 3.3 V 8 A 50mV 1% 0.5% 1% CFM60C050-DR 5 V 8 A 1% 1% 0.5% 1% 77% CFM60C090-DR 9 V 6.67 A 1% 1% 0.5% 1% 84% CFM60C120-DR 12 V 5 A 1% 1% 0.5% 1% 85% 86% CFM60C150-DR 15 V 4 A 1% 1% 0.5% 1% 86% CFM60C240-DR 24 V 2.5 A 1% 1% 0.5% 1% CFM60C300-DR 30 V 2 A 1% 1% 0.5% 1% 86% CFM60C360-DR 36 V 1.67 A 1% 1% 0.5% 1% 88% 88% CFM60C480-DR 48 V 1.25 A 1% 1% 0.5% 1% CFM101CXXX-DR Series OUTPUT RIPPLE & VOLTAGE LINE LOAD OUTPUT % EFF. PF MODEL VOLTAGE NOISE ACCURACY REGULATION REGULATION (Typ.) (Typ. ) CURRENT CFM101C120-DR 12 V 8.4 A 1% 87% 0.9 1% 0.5% 1% CFM101C150-DR 15 V 6.7 A 1% 87% 0.9 1% 0.5% 1% CFM101C200-DR 20 V 5 A 1% 1% 0.5% 1% 88% 0.9 CFM101C240-DR 24 V 4.2 A 1% 1% 0.5% 1% 88% 0.9 CFM101C480-DR 48 V 2.1 A 1% 90% 0.9 1% 0.5% 1% 1 V13 Specifications CFM40C/60C/101C XXX-DR Series Derating Curve CFM40C/60C XXX-DR INPUT SPECIFICATIONS: Voltage ............................................................ 90~264Vac 100% Frequency ......... 47 to 63Hz Inrush Current . CFM40C/60CXXX-DR 50A max. 240Vac 75% CFM101CXXX-DR 90A max. 240Vac Conducted EMI ... CISPR/FCC Class B 20LFM (Natural Convection) 50% Leakage Current ........ 3.5mA max. 25% OUTPUT SPECIFICATIONS: Hold-up Time .... CFM40C/60CXXX-DR 8ms typ. 115Vac 0% CFM101CXXX-DR 10ms typ. 115Vac Short Circuit Protection ......... Hiccup Mode (Auto Recover) 0 10 20 30 40 50 60 70 o Over Voltage Protection ......... TVS Component to Clamp Ambient Temperature ( C) Temperature Coefficient ................................. 0.05%/ CFM101C XXX-DR GENERAL SPECIFICATIONS: 100% Isolation ... Input to output = 4,242VDC Operating Temperature .. CFM40C/60CXXX-DR 0 ~ 70 (see Derating Curve) 80% CFM101CXXX-DR 0 ~ 70 (see Derating Curve) 60% 20LFM (Natural Convection) Storage Temperature .................... -20~85 40% Humidity ..................................................... 93% RH max. Non-Condensing 20% Cooling ........... Natural Convection Switching Frequency .. CFM40C/60CXXX-DR 66KHz Typical 0% CFM101CXXX-DR 100KHz Typical 0 10 20 30 40 50 60 70 o MTBF . MIL-HDBK-217F, GB, 25/115VAC T.B.D hrs Ambient Temperature ( C) Altitude .... 2000m NOTE: Dimensions ... 5.433x2.323x1.894inches (138.00x59.00x48.10mm) 1. Voltage accuracy is set at full load and 25 Ta. Weight .... 475g 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring 20MHz BW. SAFETY AND EMC: Emission and Immunity ... EN55032 Class B, FCC Part 15 Class B 3. Line regulation is measured from high line to low line with full load. EN61000-6-3, EN61000-3-2, EN61000-3-3 4. Load regulation is measured from full to 10% load. EN55024, EN61204-3, EN61000-6-1 5. CFM40C/60C/101C Input connector mates with DECA Safety .. IEC60950-1, EN60950-1, UL60950-1 T40MBB27-03 (Pitch 6.35mm) 3pin positions terminal blocks. 6. CFM40C/60C/101C Output connector mates with DECA T40MBB27-04 (Pitch 6.35mm) 4pin positions terminal blocks CFM40C/60C/101C XXX-DR Series All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 CN1: CN2: PIN CONNECTION PIN CONNECTION Pin Function Pin Function CN2 CN1 1 TOP VIEW 1 1 ACN 1 Vout (+) 2 2 3 3 2 ACL 2 Vout (+) 4 3 3 Vout (-) LED 4 Vout (-) Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 Rated Load (%) Rated Load (%)