CFM70S SERIES 70 WATT OPEN FRAME AC-DC MODULES Features Universal Input Range 90~264Vac High Efficiency up to 91% 2x 3 Open Frame Compact Size Class I and Class II No Load Input Power < 0.15W Approval IEC/EN/UL 62368-1 Meets IEC/EN 60335-1 Approval EN 55032 Class B and CISPR/FCC Class B Operating Altitude 5000m Continuous Short Circuit Protection Over Voltage Protection VOLTAGE RIPPLE& LINE LOAD %EFF. MODEL OUTPUT OUTPUT ACCURACY NOISE REGULATION REGULATION (Typ.) NUMBER VOLTAGE CURRENT NOTE1 NOTE2 NOTE3 NOTE4 NOTE5 CFM70S050 5 V 10.0 A 2% 150 mV 0.5% 1% 86% CFM70S120 12 V 5.80 A 2% 120 mV 0.5% 1% 90% CFM70S150 15 V 4.65 A 1% 150 mV 0.5% 1% 90% CFM70S240 24 V 2.92 A 1% 240 mV 0.5% 1% 90% CFM70S360 36 V 1.94 A 1% 360 mV 0.5% 1% 90% CFM70S480 48 V 1.46 A 1% 480 mV 0.5% 1% 91% Note: 1. Voltage accuracy is set at 100% full load. 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for ripple & noise measurement 20MHz BW. 3. Line regulation is measured from 90V to 264V with 100% full load. ac ac 4. Load regulation is measured from 10% to full load. 5. Typical efficiency at 230 V and 100% full load at 25. ac 6. Standard input and output connectors (CN1 and CN2) wafer with TAIWAN KING PIN TERMINAL PVHI series and mate with JST housing VHR series and JST SVH-41T-P1.1 series crimp terminal and output connectors wire 16AWG. 7. Safety approvals do not apply to the covered version only to the open frame versions. PART NUMBER Series Number of Outputs Nominal Output Voltage Type O XX -X (Option) CFM70 050 05V 120 None 12V Wafer 150 P 15V PCB Mount S CFM70 Single 240 CA 24V Cover (note7) 360 36V 480 48V Part Number Example: CFM70S120: Open Frame, 70W, Single 12V Output dc www.cincon.com 1 REVISION: V10 CFM70S Series TECHNICAL SPECIFICATIONS (All specifications are typical at nominal input, full load at 25 unless otherwise noted.) ABSOLUTE MAXIMUM RATINGS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units 90 264 V Safety approvals only to the AC input ac Input Voltage All (DC input no safety) 120 370 V dc Operating Temperature See Derating Curve All -30 80 Storage Temperature All -30 85 IEC/EN/UL 62368-1 5000 Operating Altitude All m Meets IEC/EN 60335-1 3000 INPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Operating Voltage Range All 100 240 V ac Input Frequency Range All 50 60 Hz Maximum Input Current 100% Load, V =100V All 1.5 A in ac Leakage Current All 0.1 mA V =240V , Cold start at 25 Inrush Current in ac All 130 A OUTPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units CFM70S050 4.90 5 5.10 CFM70S120 11.76 12 12.24 CFM70S150 14.85 15 15.15 Output Voltage Set Point V =Nominal V , I =Io max., T =25 V in in o c dc CFM70S240 23.76 24 24.24 CFM70S360 35.64 36 36.36 CFM70S480 47.52 48 48.48 CFM70S050 10.0 CFM70S120 5.80 CFM70S150 4.65 Operating Output Current Range V =115V and 230V ,T =25 A in ac ac c CFM70S240 2.92 CFM70S360 1.94 CFM70S480 1.46 Holdup Time V =115V ms in ac All 10 Output Voltage Regulation Load Regulation 10% Load to full load % All 1.0 Line Regulation V =High Line to low line % in All 0.5 CFM70S050 7.1 CFM70S120 15.6 CFM70S150 18.0 Over Voltage Protection Hiccup mode (Auto recovery) V dc CFM70S240 29.1 CFM70S360 43.3 CFM70S480 56.8 CFM70S050 150 1. Add a 0.1uF ceramic capacitor and a CFM70S120 120 10uF aluminum electrolytic capacitor to CFM70S150 150 output Output Ripple and Noise mV CFM70S240 240 2. Oscilloscope is 20MHz band width 3. Ambient Temperature=25 CFM70S360 360 CFM70S480 480 www.cincon.com 2 REVISION: V10