V26 EC5BU SERIES 15 WATT 2:1 INPUT DC-DC CONVERTERS FEATURES * 15W Isolated Output * Efficiency to 90% * 2:1 Input Range * Regulated Outputs * Fixed Switching Frequency * Input Under Voltage Protection * Over Current Protection * Conductive EMI Meets EN55032 Class A * Continuous Short Circuit Protection * Without Tantalum Capacitors Inside * Safety Meets IEC/EN/UL 62368-1 OUTPUT CURRENT INPUT CURRENT % CAPACITOR MODEL INPUT OUTPUT EFF. LOAD MAX. NUMBER VOLTAGE VOLTAGE MIN. MAX. NO LOAD FULL LOAD EC5BU-12S33 9-18 VDC 3.3 VDC 0 mA 4000 mA 90 mA 1280 mA 85 4000uF 3000uF EC5BU-12S05 9-18 VDC 5 VDC 0 mA 3000 mA 85 mA 1453 mA 88 1330uF EC5BU-12S12 9-18 VDC 12 VDC 0 mA 1250 mA 70 mA 1420 mA 88 1000uF EC5BU-12S15 9-18 VDC 15 VDC 0 mA 1000 mA 70 mA 1420 mA 88 1470 mA 1470uF EC5BU-12D05 9-18 VDC 5 VDC 0 mA 1500 mA 45 mA 85 1436 mA 660uF EC5BU-12D12 9-18 VDC 12 VDC 0 mA 625 mA 45 mA 87 1420 mA 550uF EC5BU-12D15 9-18 VDC 15 VDC 0 mA 500 mA 45 mA 88 EC5BU-24S33 18-36 VDC 3.3 VDC 0 mA 4000 mA 50 mA 640 mA 86 4000uF 3000uF EC5BU-24S05 18-36 VDC 5 VDC 0 mA 3000 mA 50 mA 718 mA 89 1330uF EC5BU-24S12 18-36 VDC 12 VDC 0 mA 1250 mA 20 mA 695 mA 90 1000uF EC5BU-24S15 18-36 VDC 15 VDC 0 mA 1000 mA 20 mA 695 mA 90 726 mA 1470uF EC5BU-24D05 18-36 VDC 5 VDC 0 mA 1500 mA 25 mA 86 710 mA 660uF EC5BU-24D12 18-36 VDC 12 VDC 0 mA 625 mA 25 mA 88 702 mA 550uF EC5BU-24D15 18-36 VDC 15 VDC 0 mA 500 mA 25 mA 89 EC5BU-48S33 36-75 VDC 3.3 VDC 0 mA 4000 mA 25 mA 320 mA 86 4000uF 3000uF EC5BU-48S05 36-75 VDC 5 VDC 0 mA 3000 mA 30 mA 359 mA 88 1330uF EC5BU-48S12 36-75 VDC 12 VDC 0 mA 1250 mA 20 mA 347 mA 90 1000uF EC5BU-48S15 36-75 VDC 15 VDC 0 mA 1000 mA 20 mA 351 mA 90 20 mA 363 mA 1470uF EC5BU-48D05 36-75 VDC 5 VDC 0 mA 1500 mA 86 20 mA 355 mA 660uF EC5BU-48D12 36-75 VDC 12 VDC 0 mA 625 mA 88 20 mA 351 mA 550uF EC5BU-48D15 36-75 VDC 15 VDC 0 mA 500 mA 89 NOTE: 1. Nominal Input Voltage 12, 24 or 48 VDC 1 V26 SPECIFICATIONS All Specifications Typical at Nominal Line, Full Load, and 25 Unless Otherwise Noted INPUT SPECIFICATIONS: GENERAL SPECIFICATIONS: Input Voltage Range .................... 12V .............. 9 - 18V Efficiency ......................................................... See Table 24V ..... 18 36V Isolation Voltage ............................................ 1500 VDC min. 9 48V ..... 36 75V Isolation Resistance ......................... 10 Ohm min. Under Voltage Lockout .. 12Vin power up: 8.4V . power down: 8V Isolation Capacitance .... 1000pF typ. 24Vin power up: 17V ........ power down: 16V Switching Frequency ..................................................... 350KHz typ. 48Vin power up: 34V . power down: 32V EMI/RFI ...... Conductive EMI Meets EN55032 Class A Input Surge Voltage (100ms max.) 12Vin . 25Vdc max. Case Grounding ... Connect Case to -Vin with Decoupling Y Cap 24Vin . 50Vdc max. Operating Ambient Temperature Range .......... -40 to +85 48Vin . 100Vdc max. Derating, Above 78 ... Linearly to Zero Power at +105 Input Filter ...... Pi Type Case Temperature (note4) ... 105 Cooling Natural Convection OUTPUT SPECIFICATIONS: Voltage Accuracy ........... 1.5% max. Storage Temperature Range .......................... -55 to +125 Voltage Balance (Dual) .... 2.0% max. Humidity .... 95% RH max. Non Condensing Transient Response: 25% Step Load Change .................... <500s MTBF MIL-HDBK-217-F, GB, 25 , Full Load 1200Khrs typ. Ripple & Noise, 20MHz BW (Measured with 0.1uF MLCC) ... 100mV pk-pk max. Dimensions ..................... 2.00x1.00x0.4 inches (50.8x25.4x10.2 mm) Temperature Coefficient ........................... 0.03%/ max. Case Material .. Black Coated Copper with Non-Conductive Base Short Circuit Protection ........................... Continuous Weight . 35g Line Regulation (note1) ...... Single .... 0.2% max. NOTE: Dual ................. 0.5% max. 1 . Measured from high line to low line. Load Regulation (note2) . Single .... 0.2% max. 2. Measured from full load to min. load. Dual ................. 1.0% max. 3. Maximum case temperature under any operating condition should Cross Regulation (Dual output) Load cross variation 10%/100% . 5% max. not be exceeded 105. Over Voltage Protection . Zener or TVS Clamp Current Limit . 110% - 140% Nominal Output Typical Derating curve for Natural Convection Start up Time .. 20ms max. 120% -40 78 OPTION: 100% 73 80% 1. Suffix T to the model number with remote positive on/off control: 60% Logic Compatibility .. CMOS or open collector TTL, referenced to -vin OTHERS Module on .. >5.5VDC to 75VDC or open circuit 40% XXD05 Module off .. 0 to <1.2VDC 20% 105 2. Suffix A to the model number with output voltage adjustable 0% external trim adj. range10%, single output models only. -40 -20 0 20 40 60 80 100 120 Ambient Temperature(oC) CASE B Dimensions: 0.300 0.200 0.40 7.62 5.08 10.2 PIN CONNECTION 6 2 1 Pin Function 1 +Input BOTTOM -Input 2 VIEW +V Output 3 4 Common/NP/Trim(Option) 5 -V Output 5 4 3 NP/Remote(Option) 6 *NP-NO PIN ON SINGLE OUTPUT NOTE: Pin Size is 0.040.004 Inch (1.00.1 mm)DIA All Dimensions In Inches (mm) Tolerances Inches: X.XX= 0.04 , X.XXX= 0.010 Millimeters: X.X= 1.0 , X.XX=0.25 min. 0.22 5.6 0.40 0.400 0.400 10.2 10.16 10.16 1.00 25.4 2 2.00 50.8 0.800 0.60 20.32 15.2 0.04 1.0 LOAD(%)