V14 ECLB40W-110 SERIES 40 WATT 4:1 INPUT DC-DC CONVERTERS FEATURES * 40W Isolated Output * Efficiency to 91% * 2.05 X1.2 X0.4 Six-Sided Shield Metal Case * 4:1 Input Range * Regulated Outputs * Fixed Switching Frequency * Input Under Voltage Protection * Over Current Protection * Remote On/Off * Low No Load Power Consumption * Continuous Short Circuit Protection * No Tantalum Capacitor Inside * UL60950-1 2nd (Basic Insulation) Approval * Meets EN50155 with External Circuits * Fire & Smoke Meets EN45545-2 * 3000m Operating Altitude * Full Load Operation Up to 69 with Heat-Sink M-C655 Natural Convection OUTPUT CURRENT INPUT CURRENT MODEL INPUT OUTPUT % CAPACITOR EFF. LOAD MAX. NUMBER VOLTAGE VOLTAGE NO LOAD MIN. MAX. FULL LOAD ECLB40W-110S33 43-160 VDC 3.3 VDC 0 mA 10000 mA 6 mA 340 mA 88% 10000F ECLB40W-110S05 43-160 VDC 5 VDC 0 mA 8000 mA 6 mA 409 mA 88.5% 8000F ECLB40W-110S12 43-160 VDC 12 VDC 0 mA 3333 mA 6 mA 90% 404 mA 3300F ECLB40W-110S15 43-160 VDC 15 VDC 0 mA 2666 mA 6 mA 91% 399 mA 2700F ECLB40W-110D12 43-160 VDC 12 VDC 0 mA 1667 mA 6 mA 88% 408 mA 1650F ECLB40W-110D15 43-160 VDC 15 VDC 0 mA 1333 mA 6 mA 408 mA 88.5% 1350F ECLB40W-110D24 43-160 VDC 24 VDC 0 mA 833 mA 6 mA 408 mA 89% 850F NOTE: 1. Nominal Input Voltage 110 VDC 1 V14 SPECIFICATIONS All Specifications Typical At Nominal Line, Full Load, and 25 Unless Otherwise Noted INPUT SPECIFICATIONS: GENERAL SPECIFICATIONS: Input Voltage Range .................... 110V ............... 43-160V Efficiency .......................................................... See Table Input Surge Voltage (100ms max.) ..... 200Vdc max. Iso la ti o n V o lta g e .......... Input/Output ........... 3000VDC min. Under Voltage Lockout ........... Power up ...... 40V Input/Case, Output/Case . 1600VDC min. 9 Power down ........ 38V Isolation Resistance .................... 10 Ohms min. Positive Logic Remote On/Off (note4&5) Isolation Capacitance .. 1500pF typ. Input Filter ...... Pi Type Case grounding ..... Output/case .1000pF typ. Switching Frequency ............................................................ 250KHz typ. OUTPUT SPECIFICATIONS: Voltage Accuracy ................................................. 1.5% max. EMI/RFI .. Six-Sided Continuous Shield Voltage Balance (Dual Output) ..... 1.0% max. Operating Ambient Temperature Range ............ -40 to +85 Transient Response: 25% Step Load Change De-rating, Above 45 ... Linearly to Zero Power at +105 Error Band . 5% Vout Nominal Recovery Time .. <250s Case Temperature (note5) .. 105 max. External Trim Adj. Range (Single Output Models Only) ........... 10% Cooling Natural Convection Ripple & Noise, 20MHz BW (Measured with 1uF MLCC) Storage Temperature Range ........................ -55 to +125 Vo= 3.3V&5V ......... 100mV pk-pk max Thermal Shutdown, Case Temp...................... 110 typ. Vo=12V, 15V, 12V& 15V .. 150mV pk-pk max. Humidity ................................................. 95% RH max. Non-Condensing Vo=24V ..... 200mV pk-pk max. MTBF .. MIL-HDBK-217F, GB, 25, Full Load 905Khrs typ. Safety .meet UL60950-1 2nd (Basic insulation) Temperature Coefficient ....................................... 0.02%/C max. Short Circuit Protection .................................. Continuous EMC(note6) meet EN50155(EN50121-3-2) with external filter Shock/Vibration . meet EN50155(EN61373) Line Regulation (note1) ...................................................... 0.2% max. Dimensions ............................ 2.05x1.20x0.40inches (52x30.5x10.2mm) Load Regulation (note2) ..................... Single ........................ 0.5% max. Dual.. 1.0% max. Case Material . Aluminum with Non-Conductive Base Weight .... 36g Cross Regulation (Dual output) Load cross variation 10%/100% ... 5.0% max. Over Voltage Protection . Zener or TVS Clamp NOTE : Current Limit ......................... 110%-165% Nominal Output 1. Measured from high line to low line. Start up time ....................... 15ms typ. 2. Measured from full load to min. load. 3. Logic Compatibility CMOS or open collector TTL, referenced to Vin. Module on . >3.5VDC to 75VDC or open circuit Module off .... 0 to <1.2VDC 4. Suffix to the model number with negative logic remote on/off Module on .... 0 to < 1.2 VDC Module off ....... >3.5VDC to 75VDC or open circuit 5. Maximum case temperature under any operating condition should not be Exceeded 105. 6. For information about EN50155 and RIA12, refer to application note. ECLB40W-110S15 Typical Derating Curve SIZE LB Dimensions: 120% NOTE: Pin Size is 0.040.004 Inch (1.00.1 mm)DIA All Dimensions in Inches mm -40 60 69 Tolerance Inches:x.xx=0.02 ,x.xxx=0.010 100% Millimeters:x.x=0.5 , x.xx=0.25 80% 2.05 52.0 1.800 Mounting lnserts 60% 45.72 M2.5*0.45 Through 2pl. BOTTOM VIEW Natural Convection(20LFM) 40% PIN CONNECTION Single Output Dual Output With Heatsink M-C655 PIN 20% 1 +V Input +V Input 105 2 -V Input -V Input 0% 3 +V Output +V Output -40 -20 0 20 40 60 80 100 120 4 Trim -V Output o 5 -V Output Common Ambient Temperature( C) 1.43 36.4 6 Remote On/Off External Output Trimming 0.04 6pl. 1.0 +Vout +Vout TRIM DOWN 10K Ohms TRIM TRIM TRIMPOT TRIM UP -Vout -Vout 2 1.20 30.5 0.81 20.7 0.200 5.08 0.400 10.16 0.39 0.22 min 0.350 10.0 5.6 8.89 0.40 0.052 10.2 1.33 0.400 0.400 10.16 10.16 LOAD(%)