V19 LDP40 SERIES 40 WATT OUTPUT LED POWER SUPPLY Features * 40W Single outputs * Universal AC input range 90~305Vac * Constant Current Design * Active PFC > 0.9 * Low Inrush Current < 5A * Standby Power Consumption <0.5W * Low Profile with 25.2mm Height and Narrow 40mm Width * Low Frequency Flicker Design * Continuous Short Circuit Protection * Over Temperature Protection * IP 67 Rated * Fully Isolated Plastic Case * Dimming Function: DALI/PWM/1~10VDC/Potentiometer No Load Output Constant Ripple and Output Output Output %EFF. MODEL Rated Current Noise(V p-p Rated Rated Voltage (typ.) Voltage Region max.) Current Power (max.) 24V 9-24Vdc 0.24V LDP40S240-C170BR 86% 1700mA 29Vdc 40.80W 24V 16-24Vdc 2.0V LDP40S240-C170B 89% 24V 9-24Vdc 0.24V LDP40S240-C140BR 85% 1400mA 29Vdc 33.60W 24V 16-24Vdc 2.0V LDP40S240-C140B 88% 36V 9-36Vdc 0.36V LDP40S360-C111BR 86% 1110mA 43Vdc 40.00W 36V 24-36Vdc 2.7V LDP40S360-C111B 89% 36V 9-36Vdc 0.36V LDP40S360-C105BR 85% 1050mA 43Vdc 37.80W 36V 24-36Vdc 2.7V LDP40S360-C105B 88% 48V 9-48Vdc 0.48V LDP40S480-C084BR 88% 840mA 56Vdc 40.32W 48V 32-48Vdc 4.8V LDP40S480-C084B 90% 48V 9-48Vdc 0.48V LDP40S480-C070BR 86% 700mA 56Vdc 33.60W 48V 32-48Vdc 4.8V LDP40S480-C070B 88% All specifications are Typical at nominal line, full load and 25C unless otherwise noted 1 V19 Order Information: Output Series Output(W) IP Code Dimming Function Rated Output Current Input Voltage Ripple Nosie Voltage LDP 40 X XXX X XXX B X 170: 1700mA 24024V 24V 140: 1400mA S Single O/P 111: 1110mA 36036V 36V with IP64 105: 1050mA CNo dimming R1% output 084: 840mA DDALI dimming 48048V 48V ripple and noise 070: 700mA P PWM 1-10V, or B 100-277 Vac 170: 1700mA Potentiometer 24024V 24V Blank10% output 140: 1400mA ripple and noise 111: 1110mA 36V 360 36V ASingle O/P 105: 1050mA with IP67 084: 840mA 48048V 48V 070: 700mA Specifications LDP40 Series Derating Curve INPUT SPECIFICATIONS: AC Input Voltage ........................................................... 90~305Vac Frequency ....... 50/60Hz Power Factor PF 0.9 115Vac/230Vac, 75%~100% Load Inrush Current .. <5A After 100uS 240Vac, Cold Start 25 Ta Cold Start Leakage Current ........ 0.75mA max. Standby Power Consumption .... <0.5W (No Dimming) Input Current (Full Load) . 0.45A/0.22A typ. 115Vac/230Vac. OUTPUT SPECIFICATIONS: Maximum Output Voltage .. See Table Constant Current Accuracy (note1) ....5% max. Current Line Regulation (note2) .... 5% max. Current Load Regulation (note3) ...... 5% max. Over Voltage Protection .. TVS Clamp Short Circuit Protection .... Hiccup Mode, Auto Recovery Over Temperature Protection ....... 105 typ. GENERAL SPECIFICATIONS: Efficiency .... See Table Temperature Coefficient .......... 0.05%/ (0~50 ) Isolation Voltage, Input to Output ....... 3.75KVac 8 Isolation resistance, Input to output .... 10 min. Operating Ambient Temperature ................ -40 ~ 70(See Derating Curve) Cooling ..... Natural Convection Storage Temperature ........................ -40 ~ 85 Operating Humidity ....... 20%~95% RH Non-Condensing. Operating Altitude .. Sea Level to 3000m NOTE: 1. Current accuracy is set at nominal input voltage and full load. MTBF, MIL-HDBK-217F (25 Ta) .. 200Khrs. 2. Current line regulation is measured from high line to low line with full load. MECHANICAL CHARACTERISTICS: Dimensions...... 6.614x1.575x0.992 Inches (168.00x40.00x25.20mm) 3. Current load regulation is measured minimum to maximum of the Weight ... 350g constant current region. 4. All specifications are typical at 230Vac, vo max., full load and 25 SAFETY AND EMISSIONS: Safety ............................................. UL8750, IEC61347-1, IEC61347-2-13 unless other noted. EMI ................ FCC Part 15/EN55015 Class B 5. The input/output wires accessibility shall be evaluated during final EMS .................................... EN61547, EN61000-4-2, 3, 4, 5, 6, 8, 11 system assembly. EN61000-3-2 Harmonic Class C, EN61000-3-3 All specifications are Typical at nominal line, full load and 25C unless otherwise noted 2