V19 TRG10R SERIES 10W SWITCHING ADAPTER Features * Universal Input: 90~264Vac * Continuous Short Circuit Protection * Interchangeable AC Plugs * EMI Meets EN55022 Class B and CISPR/FCC Class B * Meet CoC V5 Tier 2 & DoE Level VI (Output cable length 1800mm) * Over Voltage Protection * No Load Power Consumption<75mW Ordering information TRG10RXXX - XX E XX Model No. DC Plug Type With OVP DC Cable Length and Type 01: 720mm 02: 1220mm 03: 1800mm 11: 720mm with Ferrite Core 12: 1220mm with Ferrite Core 13: 1800mm with Ferrite Core * 18AWG / UL1185 for Vo: 5V, 5.9V, 6V, 7.5V, 9V * 20AWG / UL1185 for Vo: 12V, 13.6V * 22AWG / UL1185 for Vo: 15V, 18V * 24AWG / UL1185 for Vo: 24V VOLTAGE LINE LOAD OUTPUT OUTPUT RIPPLE & NOISE AVG. MODEL ACCURACY REGULATION REGULATION VOLTAGE CURRENT NOTE 1 EFF. NOTE 2 NOTE 3 NOTE 4 TRG10R050 5V 1600mA 50mV 2% 1% 4% 77.37% TRG10R059 5.9V 1500mA 1% 2% 1% 3% 78.12% TRG10R060 6.0V 1500mA 1% 2% 1% 3% 81.57% TRG10R075 7.5V 1200mA 1% 2% 1% 3% 81.57% TRG10R090 9V 1100mA 1% 2% 1% 2% 82.14% TRG10R120 12V 850mA 1% 2% 1% 2% 82.32% TRG10R136 13.6V 750mA 1% 2% 1% 2% 82.32% TRG10R150 15V 700mA 1% 2% 1% 2% 82.49% TRG10R180 18V 550mA 1% 2% 1% 2% 82.14% TRG10R240 24V 400mA 1% 2% 1% 2% 81.96% Specifications are subject to change without notice. 1 V19 Specifications TRG10R Series Derating Curve INPUT SPECIFICATIONS: 100% Voltage ....................................................... 90~264Vac 75% Frequency ...... 47 to 63Hz Input Current ...................................... 0.4A max. 20LFM(Natural Convection) 50% Inrush Current .................... 40A max. 240Vac Conducted EMI . CISPR/FCC Class B 25% Leakage Current . 0.25mA max. 0% OUTPUT SPECIFICATIONS: -20 -10 0 10 20 30 40 50 60 Holdup Time 10mS typ. 115Vac o Ambient Temperature( C) Short Circuit Protection . Continuous(Auto Recovery) Over Voltage Protection ................. TVS Component to Clamp NOTE: Temperature Coefficient .............................. 0.05%/ 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring 20MHz BW. GENERAL SPECIFICATIONS: Isolation Input to output = 4,242VDC 2. Voltage setpoint at 60% full load. Operating Temperature ............................. -20 ~ 60(see Derating Curve) 3. Line regulation is measured from 100Vac to 240Vac with full load. 4. Load regulation is measured from 60% to full load and from 60% to Storage Temperature .................. -20~85 Humidity .............. 93% RH max. Non condensing 20% load (60% +/- 40% load). Cooling .. Natural Convection Switching Frequency .. 67KHz typ. MTBF . MIL-HDBK-217F, GB, 25/115VAC . 200K hrs min. Altitude 2000m Dimensions .... 2.858x1.823x1.402lnches (72.6x46.3x35.6mm) Weight 130g(0.29 Pounds) SAFETY AND EMC: Emission and lmmunity . EN55022 Class B, FCC Part 15 Class B EN61000-6-3, EN61000-3-2, EN61000-3-3 EN55024, EN61204-3, EN61000-6-1 Safety . Class II, IEC60950-1, EN60950-1, UL60950-1 Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 UNIT: inches(mm) DC Plug type: V+ ) V- DC Plug:Right Angle(5.5/2.1)L12mm 18AWG / 1800mm Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 Rated Load(%)