TR160M SERIES 160 WATT MEDICAL SWITCH ADAPTER Features Universal Input Range 80~264VAC Meets EN55011 Class B and CISPR/FCC Class B Continuous Short Circuit Protection Over Voltage Protection No Load Input Power Consumption<150mW Meets CoC Tier 2 and DOE Level VI Meets IEC/EN 60335-1 IEC/EN/UL 60601-1 2 MOPP Approval Class I (TR160MA), Class II (TR160MB) Operating Altitude 5000m IP22 RIPPLE & VOLTAGE LINE LOAD %EFF. MODEL OUTPUT OUTPUT NOISE ACCURACY REGULATION REGULATION (Typ.) NUMBER VOLTAGE CURRENT NOTE1 NOTE1 NOTE3 NOTE4 NOTE5 TR160MA120 12 V 12.5A 1% 2% 1% 4% 91% TR160MA240 24 V 6.66 A 1% 2% 1% 4% 92% TR160MA360 36 V 4.44 A 1% 2% 1% 4% 92% TR160MA480 48 V 3.33A 1% 2% 1% 4% 93% TR160MB120 12 V 12.5A 1% 2% 1% 4% 91% TR160MB240 24 V 6.66 A 1% 2% 1% 4% 92% TR160MB360 36 V 4.44 A 1% 2% 1% 4% 92% TR160MB480 48 V 3.33A 1% 2% 1% 4% 93% Note: 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for ripple & noise measuring 20MHz BW. 2. Voltage accuracy is set at 60% full load. 3. Line regulation is measured from 100Vac to 240Vac with full load. 4. Load regulation measured from 60% to 100% full load and from 60% to 20% load (60% +/- 40% full load). 5. Typical efficiency at 230 VAC and 75% full load at 25C. PART NUMBER Series Output Voltage DC Plug Type OVP DC Cable Length and Type -XX XX TR160MX XXX X X=A or B 120: 12VDC E: with OVP 471:950mm with Ferrite Core A: Class I 240: 24VDC 12:1220mm with Ferrite Core B: Class II 360: 36VDC 13:1800mm with Ferrite Core 480: 48VDC *UL2464 Cable for All Models 12V: Output Cable Length 950mm, DIN Power Plug 24V: Output Cable Length 1220mm, DC Jack 36V & 48V: Output Cable Length 1800mm, DC Jack Part Number Example: TR160MA480-02E13,,160W ,Class I , 48VDC Output , Cable Length 1800mm . www.cincon.com 1 REVISION: V10 TR160M Series TECHNICAL SPECIFICATIONS (All specifications are typical at nominal input, full load at 25C unless otherwise noted.) ABSOLUTE MAXIMUM RATINGS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Input Voltage 80 264 V All ac Operating Temperature See Derating Curve C All -20 70 Storage Temperature C All -40 85 Input/Output Isolation Voltage 1 minute V All 4000 ac Operating Altitude m All 5000 INPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Operating Voltage Range V All 100 240 ac Input Frequency Range Hz All 47 60 Maximum Input Current 100% Load, V =100Vac A in All 2.0 Leakage Current (Earth) uA All 300 Leakage Current (Tounch) uA All 100 Under Voltage Protection V All 60 66 70 OUTPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units TR160MA/B120 11.76 12 12.24 TR160MA/B240 23.52 24 24.48 Output Voltage Set Point V =Nominal V , I =60% Load, T =25. V in in o c dc TR160MA/B360 35.28 36 36.72 TR160MA/B480 47.04 48 48.96 TR160MA/B120 12.5 TR160MA/B240 6.66 Operating Output Current A Range TR160MA/B360 4.44 TR160MA/B480 3.33 Holdup Time V =115Vac ms in All 25 Output Voltage Regulation Load Regulation 40% Load to Full Load % All 4.0 Line Regulation V =High Line to Low Line % in All 1.0 TR160MA/B120 13.5 TR160MA/B240 30 Over Voltage Protection V dc TR160MA/B360 42 TR160MA/B480 56 TR160MA/B120 120 1. Add a 0.1uF Ceramic Capacitor and a 10uF Aluminum Electrolytic Capacitor to Output. TR160MA/B240 150 Output Ripple and Noise mV 2. Oscilloscope is 20MHz Band Width. TR160MA/B360 240 3. Ambient Temperature=25 TR160MA/B480 480 TR160MA/B120 122500 1. Ambient Temperature=25 TR160MA/B240 6600 Load Capacitance uF 2. Input Voltage is 115VAC and 230VAC TR160MA/B360 4330 3. Output is max. Load TR160MA/B480 3240 TR160MA/B120 91 Output is Rated Load TR160MA/B240 92 Efficiency % Ambient Temperature=25 TR160MA/B360 92 Input Voltage is 230VAC TR160MA/B480 93 www.cincon.com 2 REVISION: V10