V15 TR30M SERIES 30W MEDICAL SWITCHING ADAPTER Features * Universal Input: 90~264Vac * Meets EN60601-1 and EN55011 Class B * Continuous Short Circuit Protection * Over Voltage Protection * CEC Level Compliant except TR30M050 Meets CEC Level (Output Cable Length 1800mm) (TR30M050: Output Cable Length 720mm) * Efficiency & Standby Power Meet Level V (Option) (Output Cable Length 1800mm) (TR30M050: Output Cable Length 720mm) (TR30M090: Output Cable Length 1220mm) * Meets 2MOPP Ordering information TR30MXXX - XX E XX Model No. DC Plug Type DC Cable Length and Type 01: 720mm 02: 1220mm 03: 1800mm 11: 720mm with Ferrite Core 12: 1220mm with Ferrite Core 13: 1800mm with Ferrite Core * 18AWG / SPT1 VOLTAGE LINE LOAD OUTPUT RIPPLE & NOISE % EFF. (Typ.) OUTPUT MODEL ACCURACY REGULATION REGULATION CURRENT VOLTAGE NOTE 1 NOTE 5 NOTE 2 NOTE 3 NOTE 4 TR30M050 5V 4A 50mVp-p 2% 1% 6% 76% TR30M090 9V 3A 90mVp-p 2% 1% 4% 82% TR30M120 12V 2.5A 120mVp-p 2% 1% 3% 82% TR30M150 15V 2A 150mVp-p 2% 1% 3% 85% TR30M180 18V 1.65A 180mVp-p 2% 1% 2% 85% TR30M240 24V 1.25A 240mVp-p 2% 1% 2% 84% Specifications are subject to change without notice. 1 V15 Specifications TR30M Series Derating Curve INPUT SPECIFICATIONS: 100% Voltage ....................................................... 90~264Vac 80% Frequency ...... 47 to 63Hz Inrush Current ..................... 50A max. 240Vac 60% 20LFM(Natural Convection) Input Current ...................................... 0.6A max. 40% OUTPUT SPECIFICATIONS: 20% Holdup Time 16ms typ. 115Vac 0% Short Circuit Protection . Continuous(Auto Recovery) 0 10 20 30 40 50 60 Over Voltage Protection ............... TVS Component to Clamp o Ambient Temperature( C) Temperature Coefficient ............................ 0.05%/ GENERAL SPECIFICATIONS: NOTE: Isolation Input to output = 5,656VDC 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring 20MHz BW. Operating Temperature ................................... 0 ~ 60 (see derating curve) 2. Voltage setpoint at 60% full load. Storage Temperature .................. -20~85 Humidity .................. 93% RH max. Non condensing 3. Line regulation is measured from 100Vac to 240Vac with full load. Cooling .. Natural Convection 4. Load regulation is measured from 60% to full load and from 60% to Switching Frequency .. 70KHz Typical 20% load (60% +/- 40% load). 5. Typical efficiency at 230VAC and full load at 25. MTBF .. MIL-HDBK-217F, GB, 25/115VAC . 300K hrs min. 6. Various TR Series adapters are PSE certified. PSE certification Altitude 3000m Dimensions .. 4.331x1.969x1.181Inches (110.00x50.00x30.00mm) alone is not sufficient for importation into Japan. A valid PSE mark Weight 220g(0.49 Pounds) must contain the name of the importer as shown in the example below. If PSE mark is required, the name of the registered importer must be SAFETY AND EMC: supplied to Cincon on order placement. Product labels will not contain Emission and lmmunity .. EN55011, EN60601-1-2, EN61000-3-2 PSE mark if importer name is not supplied. Consult factory or local EN61000-3-3 representative for details. Safety . IEC60601-1:2005, EN60601-1:2006, ANSI/AAMI ES60601-1:2005 Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 4.331 110.00 70.866 1800.00 1.969 50.00 LED DC Plug type: V+ ) V- DC Plug:Right Angle (5.5 /2.1)L12mm 18AWG / 1800mm IEC320/C8 Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 1.181 30.00 1.969 50.00 Rated Load(%)