V19 TR30RAM SERIES 30W MEDICAL SWITCHING ADAPTER Features * Universal Input Range 90~264VAC * Continuous Short Circuit Protection * Over Voltage Protection * Meets EN60601-1 and EN55011 Class B * Meets 2MOPP * Efficiency & Standby Power Meet Level V (Output Cable Length1800mm) * Provide PSE Mark Ordering information TR30RAMXXX - XX E XX - XX -BK Model No. DC Plug Type DC Cable Length and Type Color of Overmold Case 01: 720mm BE: Blue 02: 1220mm GY: Gray 03: 1800mm RD: Red 11: 720mm with Ferrite Core PE: Purple 12: 1220mm with Ferrite Core OE: Orange 13: 1800mm with Ferrite Core * 18AWG / UL1185 * 16AWG / UL1185 for 5V9V RIPPLE & VOLTAGE LINE LOAD OUTPUT OUTPUT % EFF. (Typ.) MODEL NOISE ACCURACY REGULATION REGULATION VOLTAGE CURRENT NOTE 5 NOTE 2 NOTE 1 NOET 3 NOET 4 80% TR30RAM050 5 V 4.0 A 1% 2% 1% 6% TR30RAM090 9 V 3.0 A 1% 2% 1% 3% 84% TR30RAM120 12 V 2.5 A 1% 2% 1% 2% 84% TR30RAM150 15 V 2.0 A 1% 2% 1% 2% 85% 85% TR30RAM180 18 V 1.67 A 1% 2% 1% 2% TR30RAM240 24 V 1.25 A 1% 2% 1% 2% 86% Specifications are subject to change without notice. 1 V19 Specifications TR30RAM Series Derating Curve INPUT SPECIFICATIONS: 100% Voltage ....................................................... 90~264Vac 80% Frequency ........ 47 to 63Hz 60% Input Current ........... 100Vac/0.8A max., 240Vac/0.4A max. 20LFM(Natural Convection) Inrush Current ...Cold start 25 100A max. 240Vac 40% Leakage Current 100A max. 20% 0% OUTPUT SPECIFICATIONS: 0 10 20 30 40 50 60 Hold-up Time 10ms typ. 115Vac o Ambient Temperature( C) Short Circuit Protection . Hiccup Mode (Auto Recovery) NOTE: Over Voltage Protection .............. TVS Component to Clamp 1. Voltage accuracy is set at 60% load and 25 Ta. Temperature Coefficient ............................ 0.05%/ 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring 20MHz BW. GENERAL SPECIFICATIONS: Isolation Input to output = 4,000VAC (5,656VDC) 3. Line regulation measured from 100Vac to 240Vac with full load. 4. Load regulation measured from 60% to full load and from 60% to Operating Temperature .................................. 0 ~ 60(see drating curve) Storage Temperature .................. -20~85 20% load (60% +/- 40% load) Humidity .................... 93% RH max. Non condensing 5. Typical efficiency with 230 VAC and max. load at 25C. 6. Various TR Series adapters are PSE certified. PSE certification Cooling .. Natural Convection Switching Frequency .. 70KHz Typical alone is not sufficient for importation into Japan. A valid PSE mark MTBF .... MIL-HDBK-217F, GB, 25/115VAC .... 200Khrs min. must contain the name of the importer as shown in the example below. Altitude 3000m If PSE mark is required, the name of the registered importer must be supplied to Cincon on order placement. Product labels will not contain Dimensions .... 4.278x2.440x1.445Inches (108.67x61.98x36.70mm) PSE mark if importer name is not supplied. Consult factory or local Weight 300g(0.67 Pounds) representative for details SAFETY AND EMC: Emission and lmmunity (Ed. 4.0) . EN55011 Class B, FCC CFR47 Part 18 Class B EN60601-1-2, EN61000-3-2-3, EN61000-4-2, 3, 4, 5, 6, 8, 11 Safety (Ed. 3.1) .. IEC60601-1:2005+A1:2012 EN60601-1:2006+A11:2011+A1+A12, UL ANSI/AAMI ES60601-1:2005 IEC 60950-1, EN60950-1, UL60950-1 Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 DC Plug type: V+ ) V- DC Plug :Straight(5.52.1) L12mm 18AWG1800mm + - 70.866 1800.00 1.969 50.00 4.278 108.67 Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 0.248 6.30 2.440 61.98 1.515 38.50 0.157 4.00 0.712 18.10 Max 0.639 16.00 0.874 22.20 0.005 0.13 1.445 36.70 0.669 17.00 0.027 0.70 0.055 1.40 TR30RAM/TR15RA-A 1.102 28.00 0.492 12.50 0.002 0.05 Rated Load(%) 0.727 18.47 0.002 0.05 1.102 28.00 0.748 19.00 0.019 0.50 0.665 16.90 0.0118 0.30 0.343 8.70 0.019 0.50 1.275 32.40 1.137 28.90