TR30RAM SERIES 30W MEDICAL SWITCHING ADAPTER Features * Universal Input Range 90-264VAC * Continuous Short Circuit Protection * Over Voltage Protection * Meets EN60601-1 and EN55011 Class B * CEC Level IV Compliant (Output Cable Length 1800mm) (TR30RAM050: Output Cable Length 1500mm) * Efficiency & Standby Power Meet Level V (Option) (Output Cable Length 1800mm) (TR30RAM050 TR30RAM090 Output Cable Length1220mm) * Provide PSE Mark Ordering information TR30RAMXXX - XX E XX - XX -BK Model No. DC Plug Type DC Cable Length and Type Color of Overmold Case r 01: 720mm BE: Blue 02: 1220mm GY: Gray 03: 1800mm RD: Red 11: 720mm with Ferrite Core PE: Purple 12: 1220mm with Ferrite Core OR: Orange 13: 1800mm with Ferrite Core * 18AWG / UL1185 * 16AWG / UL1185 for 5V9V OUTPUT MAX. MIN. RIPPLE & VOLTAGE LINE LOAD % EFF. MODEL VOLTAGE LOAD LOAD NOISE ACCURACY REGULATION REGULATION (Typ.) 73% TR30RAM050 5V 4.0A 0A 1% 2% 1% 6% TR30RAM090 9V 3.0A 0A 1% 2% 1% 3% 76% 79% TR30RAM120 12V 2.5A 0A 1% 2% 1% 2% TR30RAM150 15V 2.0A 0A 1% 2% 1% 2% 81% 81% TR30RAM180 18V 1.67A 0A 1% 2% 1% 2% TR30RAM240 24V 1.25A 0A 1% 2% 1% 2% 83% Specifications are subject to change without notice. 1 Specifications TR30RAM Series Derating Curve INPUT SPECIFICATIONS: 100% Voltage ....................................................... 90~264Vac 80% Frequency ........ 47 to 63Hz 60% 20LFM(Natural Convection) Input Current ............................... 0.4~0.8A max. 40% Inrush Current .Cold start 25 100A max. 240Vac 20% Leakage Current 100 A max. 0% 0 10 2030405060 OUTPUT SPECIFICATIONS: o Ambient Temperature( C) Holdup Time 10ms typ. 115Vac Short Circuit Protection . Continuous(Auto Recovery) NOTE: Over Voltage Protection .............. TVS Component to Clamp 1. Voltage setpoint at 60%l load Temperature Coefficient ............................ 0.05%/ 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring 20MHz BW. GENERAL SPECIFICATIONS: Isolation Input to output = 5,656VDC 3. Line regulation measured from 100Vac to 240Vac with full load. 4. Load regulation measured from 60% to full load and from 60% to Operating Temperature .................................. 0 ~ 60 (see Drating Curve) Storage Temperature .................. -20~85 20% load (60% +/- 40% load) 5. Various TR Series adapters are PSE certified. PSE certification Humidity .................... 93% RH max. Non condensing alone is not sufficient for importation into Japan. A valid PSE mark Cooling .. Natural Convection Switching Frequency .. 70KHz Typical must contain the name of the importer as shown in the example below. MTBF .... MIL-HDBK-217F, GB, 25 /115VAC .... 200K hrs min. If PSE mark is required, the name of the registered importer must be Altitude 3000m supplied to Cincon on order placement. Product labels will not contain PSE mark if importer name is not supplied. Consult factory or local Dimensions .... 4.278x2.440x1.445Inches (108.67x61.98x36.70mm) representative for details Weight 300g(0.67 Pounds) SAFETY AND EMC: Emission and lmmunity .EN55011 Class B,EN61000-3-2, EN61000-3-3 EN60601-1-2, IEC61000-4-2,4,5,6,8,11 FCC CFR47 Part 18 Class B Safety .IEC60601-1, EN60601-1, UL60601-1 Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 DC Plug type: V+ ) V- DC Plug :Straight(5.52.1) L12mm 18AWG1800mm + - 70.866 1800.00 1.969 50.00 4.278 108.67 Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 0.248 6.30 2.440 61.98 0.157 4.00 1.515 38.50 0.712 18.10 Max 0.639 16.00 0.874 22.20 0.005 0.13 1.445 36.70 0.669 17.00 0.027 0.70 0.055 1.40 TR30RAM/TR15RA-A 1.102 28.00 0.492 12.50 0.002 0.05 Rated Load(%) 0.727 18.47 0.002 0.05 0.748 19.00 0.019 0.50 1.102 28.00 0.665 16.90 0.0118 0.30 0.343 8.70 0.019 0.50 1.275 32.40 1.137 28.90