TR70M SERIES 70 WATT MEDICAL SWITCH ADAPTER Features Universal Input Range 80~264Vac High Efficiency up to 91% Class I (TR70MA), Class II (TR70MB) No Load Input Power Consumption < 150mW Approval IEC/EN/UL 60601-1 2 MOPP Approval IEC/EN 60601-1-11 (TR70MB) Home Healthcare Applications (TR70MB) Approval IP21 (TR70MB) Approval EN55011 and CISPR/FCC Class B Meets IEC/EN 60335-1 Operating Altitude 5000m Continuous Short Circuit Protection Over Voltage Protection Meets CoC Tier 2 and DOE Level VI RIPPLE & VOLTAGE LINE LOAD %EFF. MODEL OUTPUT OUTPUT NOISE ACCURACY REGULATION REGULATION (Typ.) NUMBER VOLTAGE CURRENT NOTE1 NOTE2 NOTE3 NOTE4 NOTE5 TR70MA120 12 V 5.8 A 120 mV 2% 1% 5% 89% TR70MA150 15 V 4.65 A 150 mV 2% 1% 3% 89% TR70MA180 18 V 3.9 A 180 mV 2% 1% 2% 89% TR70MA240 24 V 3.0 A 240 mV 2% 1% 2% 90% TR70MA360 36 V 1.9 A 360 mV 2% 1% 2% 90% TR70MA480 48 V 1.5 A 480 mV 2% 1% 2% 91% TR70MB120 12 V 5.8 A 120 mV 2% 1% 5% 89% TR70MB150 15 V 4.65 A 150 mV 2% 1% 3% 89% TR70MB180 18 V 3.9 A 180 mV 2% 1% 2% 89% TR70MB240 24 V 3.0 A 240 mV 2% 1% 2% 90% TR70MB360 36 V 1.9 A 360 mV 2% 1% 2% 90% TR70MB480 48 V 1.5 A 480 mV 2% 1% 2% 91% Note: 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for ripple & noise measuring 20MHz BW. 2. Voltage accuracy is set at 60% full load. 3. Line regulation is measured from 100V to 240V with full load. ac ac 4. Load regulation measured from 60% to 100% full load and from 60% to 20% full load (60%40% full load). 5. Typical efficiency at 230V and 75% full load at 25. ac 6. TR70MA120 & TR70MB120 of 115VAC meet DoE Level VI and 230VAC meet CoC Tier 2 PART NUMBER Series Output Voltage DC Plug Type Cable Type Cable Length XXX -XX E XX TR70M X 12012V 01720mm 15015V 021220mm Class I A 180 031800mm 18V 70W Medical BClass II 240 See Page 6 EUL1185 with OVP 11720mm with Ferrite Core 24V Adapter 1220mm with Ferrite Core 36036V 12 48048V 131800mm with Ferrite Core See page 6 for restrictions Part Number Example: TR70MA120-01E02, 70W, Class I, 12V Output, DC Jack Type, Cable Length 1220mm dc www.cincon.com 1 REVISION: V13 TR70M Series TECHNICAL SPECIFICATIONS (All specifications are typical at nominal input, full load at 25 unless otherwise noted.) ABSOLUTE MAXIMUM RATINGS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Input Voltage All 80 264 V ac Operating Temperature See Derating Curve All -30 70 Storage Temperature All -40 85 Input/Output Isolation Voltage 1 minute All 4400 V ac Operating Altitude All 5000 m INPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Operating Voltage Range All 100 240 V ac Input Frequency Range All 47 63 Hz Maximum Input Current 100% Load, V =100V All 1.5 A in ac Leakage Current (Earth) TR70MA 300 uA Leakage Current (Touch) All 90 uA Under Voltage Protection All 60 65 70 V ac Inrush Current V =240V , Cold start at 25 All 100 A in ac OUTPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units TR70MA/B120 11.76 12 12.24 TR70MA/B150 14.7 15 15.3 TR70MA/B180 17.64 18 18.36 V =115V and 230V , I =60% Full load in ac ac o Output Voltage Set Point V dc T =25 c TR70MA/B240 23.52 24 24.48 TR70MA/B360 35.28 36 36.72 TR70MA/B480 47.04 48 48.96 TR70MA/B120 0 5.8 TR70MA/B150 0 4.65 TR70MA/B180 0 3.9 V =115V and 230V ,T =25 Operating Output Current Range in ac ac c A TR70MA/B240 0 3.0 TR70MA/B360 0 1.9 TR70MA/B480 0 1.5 Holdup Time V =115V All 8 10 ms in ac Output Voltage Regulation TR70MA/B120 5.0 TR70MA/B150 3.0 TR70MA/B180 2.0 Load Regulation 60%40% Full load change % TR70MA/B240 2.0 TR70MA/B360 2.0 TR70MA/B480 2.0 Line Regulation V =High line to low line, full load All 1.0 % in TR70MA/B120 13.5 TR70MA/B150 16.5 TR70MA/B180 19.5 Over Voltage Protection IC component to clamp (auto recovery) V dc TR70MA/B240 26 TR70MA/B360 40 TR70MA/B480 53.5 Over Current Protection Auto recovery All 130 150 % Short Circuit Protection Auto recovery All www.cincon.com 2 REVISION: V13