V11
TRE15RD SERIES
15W SWITCHING
ADAPTER
Features
* Universal Input Range 90~264Vac
* Meets EN55032 Class B and CISPR/FCC Class B
* Continuous Short Circuit Protection
* Over Voltage Protection
Meet CoC Tier 2 & DoE Level VI
*
(Output Cable Length 1800mm)
* No Load Power Consumption<75mW
Ordering information
TRE15RDXX - XX G XX
Model No. DC Plug Type UL1571 WITH OVP DC Cable Length and Type
01: 720mm
02: 1220mm
03: 1800mm
11: 720mm with Ferrite Core
12: 1220mm with Ferrite Core
13: 1800mm with Ferrite Core
* 20AWG for 5V, UL1571 or Equivalent
* 18AWG for 9V, UL1571 or Equivalent
* 24AWG for 12V, 15V, 24V, UL1571 or Equivalent
OUTPUT OUTPUT RIPPLE & VOLTAGE LINE LOAD AVERAGE
MODEL VOLTAGE CURRENT NOISE ACCURACY REGULATION REGULATION EFFICENCY min.
NOTE 1 NOTE 2 NOTE 3 NOTE 4 NOTE 5
TRE15RD050 5 V 2.0 A 50mVp-p 2% 1% 4% 79.0%
TRE15RD090 9 V 1.4 A 90mVp-p 2% 1% 2% 83.5%
TRE15RD120 12 V 1.0 A 100mVp-p 2% 1% 2% 83.3%
TRE15RD150 15 V 1.0 A 100mVp-p 2% 1% 2% 84.5%
TRE15RD240 24 V 0.63 A 100mVp-p 2% 1% 2% 84.5%
Specifications are subject to change without notice.
1 V11
Specifications TRE15RD Series Derating Curve
Natural Convection
INPUT SPECIFICATIONS:
100%
Voltage ..................................................................... 90~264Vac
Frequency ........ 47 to 63Hz
80%
Input Current ...................................... 0.5A max.
Inrush Current .................... Cold Start @25 50A max. @ 240Vac 60%
TRE15RD050,090,120
Leakage Current .. 0.25mA max.
TRE15RD150,240
40%
OUTPUT SPECIFICATIONS:
20%
Hold-up Time .. 10ms typ. @115Vac
Short Circuit Protection .. Continuous(Auto Recovery)
0%
Over Voltage Protection .................... IC Component to Clamp
-20 -10 0 10 20 30 40 50 60 70 80
o
Ambient Temperature( C)
Temperature Coefficient ................................ 0.05% /
GENERAL SPECIFICATIONS: SAFETY AND EMC:
Isolation ...... Input to output = 3,000VAC. Emission and Immunity ........ EN55032 Class B, FCC Part 15 Class B
EN61000-6-3, EN61000-3-2, EN61000-3-3
Operating Temperature ................................ -20~ 60 (see derating curve)
Storage Temperature .................. -20~85 EN55024, EN61204-3, EN61000-6-1
Humidity .................................................... 93% RH max. Non condensing Safety .. Class II, IEC60950-1, EN60950-1, UL60950-1
Cooling . Natural Convection
NOTE:
Switching Frequency Full Load 115V/85KHz typ.
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
230V/65KHz typ.
ripple & noise measuring @20MHz BW.
MTBF . MIL-HDBK-217F, GB, at 25/115VAC .. 330Khrs min. 2. Voltage setpoint at 60% full load.
Altitude ........ 5000m
3. Line regulation measured from 100Vac to 240Vac full load.
Dimensions .... 2.835x2.244x1.299 inches (72.00x57.0x33.00mm))
4. Load regulation measured from 60% to full load and from 60% to
Weight .. 100g(0.22 Pounds)
20% load (60% +/- 40% load).
5. Average Efficiency measured at 25%,50%,75%,100% load and input
voltage is 115Vac/230Vac.
Mechanical Specification
Typical at 25C, nominal line and 75% load, unless otherwise Specified
2
Rated Load(%)