V21 TRG36 SERIES 36W SWITCHING ADAPTER Features *Universal Input Range 90-264VAC * Meets EN55032 Class B and CISPR/FCC Class B, Conducted * Continuous Short Circuit Protection * Leakage Current 0.25mA Max. * Over Voltage Protection * No Load Power Consumption<75mW * Approved IEC/EN/UL62368-1 * Meet CoC V5 Tier 2 & DoE Level VI * (Output cable length 1800mm) (TRG36A09: Output Cable Length1220mm) (TRG36A05: Output Cable Length 720mm 18AWG/UL2464) Ordering information TRG36AXX- XX E XX Model No. DC Plug Type With OVP DC Cable Length and Type 01: 720mm 02: 1220mm 03: 1800mm 11: 720mm with Ferrite Core 12:1220mm with Ferrite Core 13:1800mm with Ferrite Core *18AWG/UL1185 RIPPLE & VOLTAGE LINE LOAD OUTPUT OUTPUT AVG. MODEL NOISE REGULATION REGULATION REGULATION VOLTAGE CURRENT EFF. NOTE 1 NOTE 2 NOTE 3 NOTE 4 TRG36A05 5V 4.0A 1% 2% 1% 6% 83.69% 87.30% TRG36A09 9V 3.0A 1% 2% 1% 5% 87.70% TRG36A12 12V 2.5A 1% 2% 1% 5% 87.97% TRG36A13 13.5V 2.4A 1% 2% 1% 5% 88.31% TRG36A15 15V 2.4A 1% 2% 1% 3% 88.31% TRG36A18 18V 2.0A 1% 2% 1% 2% 88.31% TRG36A24 24V 1.5A 1% 2% 1% 2% 88.31% TRG36A48 48V 0.75A 1% 2% 1% 2% Specifications are subject to change without notice. 1 V21 Specifications TRG36 Series Derating Curve INPUT SPECIFICATIONS: 100% Voltage ....................................................... 90~264Vac 80% Frequency ...... 50 to 60Hz 60% Inrush Current ..................... 60A max. 240Vac 20LFM(Natural C onvection) Leakage Current . 0.25mA max. 40% OUTPUT SPECIFICATIONS: 20% Hold-up Time 8ms typ. 115Vac 0% Short Circuit Protection . Continuous(Auto Recover) -20 -10 0 10 20 30 40 50 60 Over Voltage Protection ..TVS Component to Clamp o Ambient Temperature( C) Temperature Coefficient .................................. 0.05%/ GENERAL SPECIFICATIONS: NOTE: Isolation Input to output = 4,242VDC 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measurement 20MHz BW. Operating Temperature ................................ -20 ~ 60(see derating curve) Storage Temperature .................. -20~85 2. Voltage setpoint at 60% load. Humidity .................................................... 93% RH max. Non condensing 3. Line regulation is measured from 100Vac to 240Vac full load. Cooling ..... Natural Convection 4. Load regulation measured from 60% to 100% full load and from 60% Switching Frequency ... 67KHz typ. to 20% load (60% +/- 40% full load). MTBF . MIL-HDBK-217F, GB, at 25/115VAC . 200Khrs min. Altitude ... 2000m Dimensions ... 4.370x2.008x0.886 inches (111.00x51.00x22.50mm) Weight 190g(0.42 Pounds) AC Inlet .. IEC320/C8 SAFETY AND EMC: Emission and Immunity .... EN55032 Class B, FCC Part 15 Class B EN61000-6-3, EN61000-3-2, EN61000-3-3 EN55024, EN61204-3, EN61000-6-1 Safety .... Class II, IEC/EN/UL62368-1/60950-1 Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 4.370 111.00 70.866 1800.00 1.969 50.00 DC Plug type: V+ ) V- DC Plug:Right Angle(5.52.5 )L12mm 18AWG1800mm IEC320/C8 Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 0.886 22.50 2.008 51.00 Rated Load(%)