TRH220A SERIES 220 WATT I.T.E SWITCH ADAPTER Features Universal Input Range 90~264Vac High Efficiency up to 94% Class I No Load Input Power Consumption < 150mW Approval IEC/EN/UL 62368-1 Approval EN55032 and CISPR/FCC Class B Operating Altitude 5000m Continuous Short Circuit Protection Over Voltage Protection Meets CoC Tier 2 and DOE Level VI RIPPLE & VOLTAGE LINE LOAD %EFF. MODEL OUTPUT OUTPUT NOISE ACCURACY REGULATION REGULATION (Typ.) NUMBER VOLTAGE CURRENT NOTE1 NOTE2 NOTE3 NOTE4 NOTE5 TRH220A120 12 V 16.67 A 120 mV 2% 1% 4% 91% TRH220A240 24 V 9.17 A 200 mV 2% 1% 3% 93% 200 mV TRH220A360 36 V 6.11 A 2% 1% 2% 93% 200 mV TRH220A480 48 V 4.58 A 2% 1% 2% 94% 200 mV TRH220A560 56 V 3.93 A 2% 1% 2% 94% Note: 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for ripple & noise measuring 20MHz BW. 2. Voltage accuracy is set at 60% full load. 3. Line regulation is measured from 100V to 240V with full load. ac ac 4. Load regulation measured from 60% to 100% full load and from 60% to 20% full load (60%40% full load). 5. Typical efficiency at 230V and 75% full load at 25. ac PART NUMBER Series Output Voltage DC Plug Type Cable Type Cable Length XXX -XX E XX TRH220A X 12012V 24024V 471950mm with Ferrite Core 220W A 360 E 12 I.T.E Class I 36V See Page 6 UL2464 with OVP 1220mm with Ferrite Core Adapter 480 13 48V 1800mm with Ferrite Core 56056V See page 6 restrictions Part Number Example: TRH220A240-1538E12, 220W, Class I, 24V Output, Din Power Plug Molded Type, Cable Length 1220mm with Ferrite Core dc TRH220A360-11E13, 220W, Class I, 36V Output, DC Jack Type, Cable Length 1800mm with Ferrite Core dc www.cincon.com 1 REVISION: V11 TRH220A Series TECHNICAL SPECIFICATIONS (All specifications are typical at nominal input, full load at 25 unless otherwise noted.) ABSOLUTE MAXIMUM RATINGS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Input Voltage All 90 264 V ac Operating Temperature See Derating Curve All -30 70 Storage Temperature All -40 85 Operating Altitude All 5000 m INPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Operating Voltage Range All 100 240 V ac Input Frequency Range All 47 63 Hz Maximum Input Current 100% Load, V =100V All 2.5 A in ac Leakage Current All 0.75 mA Under Voltage Protection All 50 60 65 V Power Factor 230V /50Hz Full load All 0.92 ac Vin=240Vac, Cold start at 25 Inrush Current All 120 A OUTPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units TRH220A120 11.76 12 12.24 TRH220A240 23.52 24 24.48 V =115V and 230V , I =60% Full load in ac ac o Output Voltage Set Point TRH220A360 35.28 36 36.72 V dc T =25 c TRH220A480 47.04 48 48.96 TRH220A560 54.88 56 57.12 TRH220A120 0 16.67 TRH220A240 0 9.17 Operating Output Current Range V =115V and 230V ,T =25 TRH220A360 0 6.11 A in ac ac c TRH220A480 0 4.58 TRH220A560 0 3.93 Holdup Time V =115V All 20 22 ms in ac Output Voltage Regulation TRH220A120 4 TRH220A240 3 Load Regulation 60%40% Full load change TRH220A360 2 % TRH220A480 2 TRH220A560 2 Line Regulation V =High line to low line All 1 % in TRH220A120 13.5 TRH220A240 30 Over Voltage Protection Latch Off TRH220A360 42 V dc TRH220A480 56 TRH220A560 59.2 TRH220A120 120 1. Add a 0.1uF ceramic capacitor and a TRH220A240 200 10uF aluminum electrolytic capacitor to output Output Ripple and Noise TRH220A360 200 mV 2. Oscilloscope is 20MHz band width TRH220A480 200 3. Ambient temperature=25 TRH220A560 200 www.cincon.com 2 REVISION: V11