V12 TRH25 SERIES 25W SWITCHING ADAPTER Features * Miniature Size * Universal Input: 90~264Vac * EMI Meets EN55022 Class B and CISPR/FCC Class B * Continuous Short Circuit Protection * Over Voltage Protection * Meet CoC V5 Tier 2 & DoE Level VI (Output Cable Length 1800mm) (TRH25033: Output Cable Length 720mm) (TRH25050: Output Cable Length 1220mm) * No Load Power Consumption<75mW Ordering information TRH25 XXX - X XX X XX Model No. AC Plug Type DC Plug Type OVP DC Cable Length and Type A: USA 2 Pin E: With OVP 01: 720mm E: Europe 2 Pin 02: 1220mm U: British 3 Pin 03: 1800mm S: Australia 2 Pin 11: 720mm with Ferrite Core 12: 1220mm with Ferrite Core 13: 1800mm with Ferrite Core * 16AWG / UL1185 for Vo: 5V,3.3V * 18AWG / UL1185 for Vo:12V * 20AWG / UL1185 for Vo:15V * 22AWG / UL1185 for Vo:18V * 24AWG / UL1185 for 24V VOLTAGE LINE LOAD OUTPUT OUTPUT RIPPLE & NOISE AVG. XMODEL ACCURACY REGULATION REGULATION VOLTAGE CURRENT NOTE 1 EFF. NOTE 2 NOTE 3 NOTE 4 TRH25033 3.3V 4.0A 50mVp-p 2% 1% 6% 80.97% TRH25050 5V 4.0A 1% 2% 1% 6% 83.69% TRH25120 12V 2.1A 1% 2% 1% 5% 87.02% TRH25150 15V 1.67A 1% 2% 1% 3% 86.99% TRH25180 18V 1.4A 1% 2% 1% 2% 87.02% TRH25240 24V 1.05A 1% 2% 1% 2% 87.02% Specifications are subject to change without notice. 1 V12 TRH25 Series Derating Curve Specifications INPUT SPECIFICATIONS: 100% Voltage ....................................................... 90~264Vac Frequency ...... 47 to 63Hz 75% Inrush Current .................... 0.7A max. 50% 20LFM(Natural Convection) Inrush Current .................... 60A max. 240Vac Conducted EMI .... CISPR/FCC Class B 25% Leakage Current . 0.25mA max. 0% OUTPUT SPECIFICATIONS: -20 -10 0 10 20 30 40 50 60 Holdup Time 10ms typ. 115Vac o Ambient Temperature( C) Short Circuit Protection . Continuous(Auto Recovery) Over Voltage Protection .............. TVS Component to Clamp Temperature Coefficient ............................ 0.05%/ SAFETY AND EMC: GENERAL SPECIFICATIONS: Emission and lmmunity . EN55022 Class B, FCC Part 15 Class B Isolation ... Input to output = 4,242VDC EN61000-6-3, EN61000-3-2, EN61000-3-3 Operating Temperature .................................. -20~60(see derating curve) EN55024, EN61204-3, EN61000-6-1 Storage Temperature ................... -20~85 Safety Class II, IEC60950-1, EN60950-1, UL60950-1 Humidity ..................... 93% RH max. Non condensing Cooling ... Natural Convection NOTE: Switching Frequency ... 67KHz typ. 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring 20MHz BW. MTBF . MIL-HDBK-217F, GB, 25 /115VAC 425Khrs min. Altitude 2000m 2. Voltage setpoint at 60% full load. Dimensions ... 2.835x2.047x1.378Inches (72.00x52.00x35.00mm) 3. Line regulation measured from 100Vac to 240Vac, full load. Weight . 140g(0.31 Pounds) 4. Load regulation measured from 60% to 100% full load and from 60% to 20% load (60% +/- 40% full load). Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 Rated Load(%)