OPERATOR PANELS ELECTRONICELECTRONIC Operator panel is a simple programmable panel-mounted device for setting and measuring standard signals in control and adjustment processes: 0...10V, 0/4...20mA. The range of displayed values can be set with push-buttons and displayed as 0...9999 with a decimal point placed in any position. The device features a multi-turn potentiometer for a precision signal setting as well as convenient Stop, Right Start and Left Start push-buttons with pilot light. Specifications Supply voltage: 10...30V AC/DC Preset signal: 0...10V, 0/4...20mA Measured signal: 0...10V, 0/4...20mA Scaled preset value display (button display) Scaled measured value display (top display) Opto-isolated digital outputs to change motor direction Left Start, Right Start push-buttons with pilot light Precision multi-turn potentiometer Operating temperature: -20...60C Installation: panel-mounted, hole 90x90 mm Model: ZAD-1V2-24 Inputs / Outputs Supply WInputejcie WOutputyjcie WOutputyjcie 10- 30 0-10V Right Left 0-10V 4-20mA 4-20mA VDC/AC T1T1 T2T2 + + 1 2 3 4 5 6 7 8 9 10 www.cobi-electronic.com.plOPERATOR PANELS Programmable parameters n-00 set value lower limit -999...0...9999 n-01 set value upper limit 0...100...9999 n-02 set value decimal point position 0 0000 n-03 measured value decimal point position 0 0000 n-04 voltage/current rise time 1...5...100 s n-05 voltage/current fall time 1...5...100 s n-06 analog output control 0 potentiometer set voltage/current is supplied to the output terminals 1 potentiometer set voltage/current is supplied afeter left or right is pressed. Press stop to reduce set value 0V (0/4mA). Change in direction will result in voltage drop, change of direction output and increase in voltage/current to set value. n-07 parameter removed n-08 operation mode is set with jumpers JP1, JP2, JP3 and programmed 0 regulator 0...10V indicator 0...10V jumpers JP2, JP3 closed 0 regulator 0...20mA indicator 0...20mA jumper JP1 closed 1 regulator 4...20mA indicator 4...20mA jumper JP1 closed n-09 menu lock 0 inactive, 1 active Press and hold stop for min. 5 seconds after power on to unlock n-10 measured value lower limit -999...0...9999 n-11 measured value upper limit 0...100...9999 n-12 measured value pulsation lower threshold -999...9999 n-13 measured value pulsation upper threshold 0...9999 STOP = enter/exit menu, START LEFT/RIGHT = change value factory settings . Wiring diagram Supply WInputejcie WOutputyjcie OutputWyjcie 0-10V 10- 30 0-10V Right Left 4-20mA 4-20mA VDC/AC T1T1 T2T2 + + 1 2 3 4 5 6 7 8 9 10 www.cobi-electronic.com.pl