High Pulse Currents - High voltage FEATURES Power Semiconductor Circuits SCR Commutation APPLICATIONS Ballast controls Switching Power Supplies Operating Temperature Range -55C to +105C +10% at 1 kHz, 25C Capacitance Tolerance +5% optional 100 WVDC 250 400 630 1600 2000 0 AC voltage (50/60 Hz) VAC 160 200 400 630 650 700 For T>+85C , The voltage (DC/AC)must be decreased by (1.5/2.25)% per C Frequency (kHz) C<0.1uF 0.1uF<C<1uF C>1uF Dissipation Factor (MAX) 1 0.05% 0.04% 0.05% 25C 10 0.05% 0.06% - 100 0.16% - - Insulation Insulation Resistance Capacitance Resistance 25C (<70% RH)for 1 minute at < 0 .3 3 F 100000 M 100VDC applied >0 .3 3 F 30000 M xF Self Inductance <1 nano-Henry per mm of lead spacing Capacitance Drift Factor <0.5% after 2 years at 40C 2000 Hours, +85C with 125% of rated voltage Capacitance Change <1% of initially measured value Load Life <0.001 at 10kHz and 25C for C<1uF Dissipation Factor <0.001 at 1kHz and 25C for C>1uF Insulation Resistance >50% of maximum specified value Reliability 2 Fit, VDC<400 WVDC 1 Fit, VDC>400 WVDC (0.5xRated Voltage, 40C) Capacitance Change <10% of initially measured value 1 FIT=1 failure/1 billion Dissipation Factor <200% of initially specified value component hours Insulation Resistance >50% of maximum specified value 56 days at40C with 90 to 95%RH, +40C and no voltage applied Capacitance Change <5% of initially measured value Damp Heat test Dissipation Factor <0.005 at 1kHz and 25C Insulation Resistance >50% of maximum specified value Self Inductance <1 nano-Henry per mm of lead spacing Capacitance Drift Factor <0.5% after 2 years at 40C Capacitance Temperature -200 ppm/C, +100ppm/C Coefficient Terminal to Terminal Terminal to case 3kVAC 50/60 Hz applied between Dielectric Strength 160% of rated VDC or 150% VAC applied terminals and case for 60 seconds at for 2 Seconds and 25C 25C Dielectric Polypropylene Construction Metallized film Plastic Case and Epoxy Resin Flame Retardant materials (UL 94V-0) Leads Lead free tinned copper leads Aug-19 L 18 26.5 32 42.5 S 15 22.5 27.5 37.5 d 0.8 0.8 0.8 1.2 LL 5.0+1.0 5.0+1.0 30+5.0 30+5.0 Permissible (sinusoidal) AC voltage versus frequency for a temperature rise of 10C Not for across the line applications Aug-19