AC-DC Power Supplies Configurable Type Safety EMI OCP OVP Parallel Power World wide Inrush Remote Modular Approvals Operation Factor current ON/OFF Correction limiting ACE-series Feature CE marking Flexible modular system architecture provides Low Voltage Directive various output configuration RoHS Directive Harmonic attenuator (Complies with IEC61000-3-2) Universal input (AC85 - 264V) EMS Compliance : EN61204-3, EN61000-6-2 Remote ON/OFF control, alarm EN61000-4-2 EN61000-4-3 Safety agency approvals EN61000-4-4 UL60950-1, C-UL (CSA60950-1), EN62368-1 EN61000-4-5 Complies with DEN-AN EN61000-4-6 UL60601-1, C-UL (CSA601.1), EN60601-1 approvals (optional) EN61000-4-8 EN61000-4-11 EMI IEC60601-1-2 (2014), EN60601-1-2 (2015) (optional) Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 3-year warranty January 31, 2022 ACE-1Ordering information AC-DC Power Supplies Configurable Type AC O - OOOOOO - OO - OO ACE series 1 2 3 4 5 6 7 8 9 0 1 Abbreviation type Example recommended EMI/EMC filter R name of ACE series ACE300F NAC-06-472 2 Abbreviation power ACE450F NAC-10-472 of ACE series ACE650F NAC-20-472 3 : ACE300F ACE900F NAC-20-472 4 : ACE450F 6 : ACE650F 9 : ACE900F 3 Slot 6 Output module 4 Slot 5 Output module 5 Slot 4 Output module 6 Slot 3 Output module High voltage pulse noise type : NAP series 7 Slot 2 Output module Low leakage current type : NAM series 8 Slot 1 Output module * A higher current rating EMI/EMC filter 9 Parallel code may be recommended in view of the 0 Option (series code) *8 other devices that could be connected Refer to instruction manual 6.1 in parallel with the power supply. Safety : UL60601-1, EN60601-1 Refer to instruction manual 8. for details. 6 5 4 3 2 1 Slot * The number of slot is *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. different depending on the model. SPECIFICATIONS * Empty slot is code:O MODEL ACE300F ACE450F ACE650F ACE900F VOLTAGE V AC85 - 264 1f / DC120 - 350 (option=-U AC70 or DC100 - refer to instruction manual 6) FREQUENCY Hz 47 - 63 *1 AC100V 3.7typ 5.7typ 8.0typ 11typ CURRENT A *1 AC200V 2.0typ 3.1typ 4.2typ 5.7typ *1 AC100V 0.99typ POWER FACTOR *1 AC200V 0.95typ INPUT *2 *7 *7 AC100V 15 / 30typ 15 / 50typ INRUSH CURRENT A *2 *7 *7 AC200V 30 / 30typ 30 / 50typ *1 AC100V 74typ 75typ 77typ 77typ EFFICIENCY % *1 AC200V 78typ 78typ 80typ 80typ *3 LEAKAGE AC100V 0.5max CURRENT mA *3 AC230V 0.95max NUMBER OF SLOT 4 5 5 6 *4 TOTAL AC90 - 150V 250 400 600 800 (Peak 1k) OUTPUT W *4 OUTPUT AC170 - 264V 300 450 650 900 (Peak 1k) START-UP TIME ms 500max (ACIN100V, Io=100%) *1 HOLD-UP TIME ms 20typ (ACIN100V, Io=100%) AUXILIARY POWER (AUX) 12V 0.1A (Only for Remote ON/OFF) (option=-J 5V0.1A) FUNCTION ALARM (PR) FAN alarm, LINE alarm , INPUT-OUTPUT, RC, AUX AC3 000V 1minute, Cutoff current=10mA, DC500V 50MW min (At Room Temperature) ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current=10mA, DC500V 50MW min (At Room Temperature) *5 OUTPUT, RC, AUX(PR)-FG AC500V 1minute, Cutoff current=100mA, DC500V 50MW min (At Room Temperature) *4 OPERATING TEMP.,HUMID. AND ALTITUDE -20 to +70C, 20 - 90%RH (Non condensing) 3,000m (10,000feet ) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max ENVIRONMENT 2 VIBRATION 19.6m/s (2G) , 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G) , 11ms, once each X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN62368-1, Complies with DEN-AN (At only AC input) AGENCY APPROVALS SAFTY AND UL60601-1, EN60601-1 (At only AC input),Complies with IEC60601-1-2 4th Ed. (Refer to instruction manual 8) NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B and EN55022-B REGULATIONS *9 HARMONIC ATTENUATOR Complies with IEC61000-3-2 103X63.5X254mm (WXHXD) 127X63.5X254mm (WXHXD) 127X63.5X279mm (WXHXD) 177.5X63.5X254mm (WXHXD) *6 CASE SIZE 4.06X2.5X10 inches 5X2.5X10 inches 5X2.5X10.98 inches 6.99X2.5X10 inches OTHERS WEIGHT kg 1.7max 2.2max 2.4max 3.0max COOLING METHOD Forced cooling (built-in) *1 In case of modular power supply, the value changes by ouput wattage under the prescribed conditions. *6 Case size contains neither the terminal blocks, screw nor. composing and load factor of installed ouput modules. *2 More than 3sec. to restart. Io=100% *7 Primary inrush current / Secondary inrush current. The values in specifications mean each the model are *3 Complies with IEC62368-1 and DEN-AN 60Hz and 100% load. *8 Please contact us about safety approvals for the model with option. composed of voluntary modules that are 5V (code : C), 12V *4 Refer to Derating in detail. *9 Please contact us about class C . (code : E), 24V (code : H) and the output power is total *5 Each output module, RC and AUX are isolated. * A sound may occur from power supply at pulse loading. January 31, 2022 ACE-2