Ordering information AC-DC Power Supplies Configurable type ACO -OOOOOO -OO -OO ACE series 12 345 67 8 9 10 1 Abbreviation type R Recommended EMI/EMC Filter name of ACE series ACE300F NAC-06-472 2 Abbreviation power ACE450F NAC-10-472 of ACE series ACE650F NAC-20-472 3 : ACE300F ACE900F NAC-20-472 4 : ACE450F 6 : ACE650F 9 : ACE900F 3 Slot 6 Output module 4 Slot 5 Output module 5 Slot 4 Output module 6 Slot 3 Output module High voltage pulse noise type : NAP series 7 Slot 2 Output module Low leakage current type : NAM series 8 Slot 1 Output module *The EMI/EMC Filter is recommended 9 Parallel code *to connect with several devices. 10 Option (series code) *8 Refer to instruction manual 5.1 Safety : UL60601-1, EN60601-1 Refer to instruction manual 7. for details. 6 5 4 3 2 1 Slot *The number of slot is different depending on the model. SPECIFICATIONS *Empty slot is code:0 MODEL ACE300F ACE450F ACE650F ACE900F VOLTAGE V AC85 - 264 1f / DC120 - 350 (option=-U AC70 or DC100 - refer to instruction manual 5) FREQUENCY Hz 47 - 63 *1 AC100V 3.7typ 5.7typ 8.0typ 11typ CURRENT A *1 AC200V 2.0typ 3.1typ 4.2typ 5.7typ *1 AC100V 0.99typ POWER FACTOR *1 AC200V 0.95typ INPUT *2 *7 *7 AC100V 15 / 30typ 15 / 50typ INRUSH CURRENT A *2 *7 *7 AC200V 30 30typ 30 50typ / / *1 AC100V 74typ 75typ 77typ 77typ EFFICIENCY % *1 AC200V 78typ 78typ 80typ 80typ *3 AC100V 0.5max LEAKAGE ACE CURRENT mA *3 AC230V 0.95max NUMBER OF SLOT 4 5 5 6 *4 TOTAL AC90 - 150V 250 400 600 800 (Peak 1k) OUTPUT W *4 OUTPUT AC170 - 264V 300 450 650 900 (Peak 1k) START-UP TIME ms 500max (ACIN100V, Io=100%) *1 HOLD-UP TIME ms 20typ (ACIN100V, Io=100%) AUXILIARY POWER (AUX) 12V 0.1A (Only for Remote ON/OFF) (option=-J 5V0.1A) FUNCTION ALARM (PR) FAN alarm, LINE alarm , INPUT-OUTPUT, RC, AUX AC3 000V 1minute, Cutoff current=10mA, DC500V 50MW min (At Room Temperature) ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current=10mA, DC500V 50MW min (At Room Temperature) *5 OUTPUT, RC, AUX(PR)-FG AC500V 1minute, Cutoff current=100mA, DC500V 50MW min (At Room Temperature) *4 OPERATING TEMP.,HUMID. AND ALTITUDE -20 to +70C, 20 - 90%RH (Non condensing) 3,000m (10,000feet ) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max ENVIRONMENT 2 VIBRATION 19.6m/s (2G) , 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G) , 11ms, once each X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, Complies with DEN-AN (At only AC input) AGENCY APPROVALS SAFTY AND UL60601-1, EN60601-1 (At only AC input) (Refer to instruction manual 7) NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B and EN55022-B REGULATIONS *9 HARMONIC ATTENUATOR Complies with IEC61000-3-2 103X63.5X254mm (WXHXD) 127X63.5X254mm (WXHXD) 127X63.5X279mm (WXHXD) 177.5X63.5X254mm (WXHXD) *6 CASE SIZE 4.06X2.5X10 inches 5X2.5X10 inches 5X2.5X10.98 inches 6.99X2.5X10 inches OTHERS WEIGHT kg 1.7max 2.2max 2.4max 3.0max COOLING METHOD Forced cooling (built-in) *1 In case of modular power supply, the value changes by ouput wattage under the prescribed conditions. *6 Case size contains neither the terminal blocks, screw nor. composing and load factor of installed ouput modules. *2 More than 3sec. to restart. Io=100% *7 Primary inrush current / Secondary inrush current. *3 Complies with IEC60950 and DEN-AN 60Hz and 100% load. The values in specifications mean each the model are *8 Please contact us about safety approvals for the model with option. *4 Refer to instruction manual 4.2 Derating in detail. composed of voluntary modules that are 5V (code : C), 12V *9 Please contact us about class C. *5 Each output module, RC and AUX are isolated. (code : E), 24V (code : H) and the output power is total * A sound may occur from power supply at pulse loading. ACE-2Imput module Refer to Instruction manual 6 Input. ACE series Output module specifications 150W suitable single output 50W suitable single output 75W dual output CODE A B C D E F G H J K L M N P R Y W Z 9 ITEM *7 *7 *7 *7 Number of slots used 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 VOLTAGE V +2 +3.3 +5 +7.5 +12 +15 +18 +24 +34 +48 +3.3 +5 +12 +15 +24 5 12 15 24 MINIMUM CURRENT A 000000000000000000 0 CURRENT1 A 26 26 26 18 13 10 8.5 6.5 4.5 3.2 10 10 5 4 2.5 3 3.2 2.5 1.6 CURRENT2 A 7 4.2 3.5 2.5 *1 PEAK CURRENT A 14 12 10 8 5.5 4 5 4 LINE REGULATION mV max 20 20 20 36 48 60 72 96 120 192 20 20 48 60 96 20 48 60 60 *5 LOAD REGULATION1 mV max 40 40 40 100 100 120 120 150 180 300 40 40 100 120 150 250 600 600 600 *6 LOAD REGULATION2 mV max 500 750 750 750 *2 RIPPLE 0 to +50C 80 80 80 120 120 120 120 120 120 150 80 80 120 120 120 80 120 120 120 mVp-p max -20 to 0C*2 140 140 140 160 160 160 160 160 160 300 140 140 160 160 160 140 160 160 160 *2 0 to +50C 120 120 120 150 150 150 150 150 150 350 120 120 150 150 150 120 150 150 150 RIPPLE NOISE mVp-p max *2 -20 to 0C 160 160 160 180 180 180 180 180 180 400 160 160 180 180 180 160 180 180 180 TEMPERATURE 0 to +50C 50 50 50 90 120 150 180 240 300 480 50 50 120 150 240 50 120 150 150 COEFFICIENT mV max *3 DRIFT mV max 20 20 20 36 48 60 72 96 120 192 20 20 48 60 96 20 48 60 60 OUTPUT VOLTAGE SETTING V 2.00-2.20 3.25-3.45 4.99-5.30 7.20-7.80 11.5-12.5 14.4-15.6 17.3-18.7 23.0-25.0 33.0-35.0 46.0-50.0 3.25-3.45 4.99-5.30 11.5-12.5 14.4-15.6 23.0-25.0 4.99-5.30 11.5-12.5 14.4-15.6 23.0-25.0 *4 OUTPUT VOLTAGE ADJUSTMENT RANGE V 1.60-2.60 2.60-3.60 4.00-5.50 6.00-8.20 9.00-13.2 13.2-16.5 16.5-19.2 19.2-26.4 27.2-37.4 38.4-52.8 2.60-3.60 4.00-5.50 9.00-13.2 13.2-16.5 19.2-26.4 4.99-6.00 9.60-13.2 13.2-16.5 19.2-26.4 OVERCURRENT PROTECTION A Works over 105%min of rated current or 101%min of peak current. Automatic recovery. OVERVOLTAGE PROTECTION V 3.00-4.80 4.00-5.25 Works at 115 - 140% of rated voltage 4.00-5.25 6.90-8.40 13.8-16.8 17.25-21.0 27.6-33.6 Works at 115 - 140% of rated voltage FUNCTION Remotesensing, remote ON/OFF, alarm (LV) Remote ON/OFF, alarm (LV) 300W suitable single output 100W insulation dual output 150W dual output = CODE 2A 2B 2C 2D 2E 2F 2G 2H 2J 2K S *8 T *8 U *8 Q*7 V*7 I ITEM Number of slots used 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 VOLTAGE V +2 +3.3 +5 +7.5 +12 +15 +18 +24 +34 +48 V1:+5 V2:+5 V1:+5 V2:+12 V1:+5 V2:+24 12 15 MINIMUM CURRENT A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CURRENT1 A 60 60 60 40 25 20 17 14 10 7 10 5 10 4.2 10 2.1 6.4 5.5 CURRENT2 A 8 7 *1 PEAK CURRENT A 34 27 23 20 14 10 10 8 LINE REGULATION mV max 20 20 20 36 48 60 72 96 120 192 20 20 20 48 20 96 48 60 *5 LOAD REGULATION1 mV max 40 40 40 100 100 120 120 150 180 300 40 40 40 100 40 150 600 600 LOAD REGULATION2 mV max*6 750 750 *2 0 to +50C 80 80 80 120 120 120 120 120 120 150 80 80 80 120 80 120 140 140 RIPPLE mVp-p max *2 -20 to 0C 140 140 140 160 160 160 160 160 160 300 140 140 140 160 140 160 200 200 *2 RIPPLE NOISE 0 to +50C 120 120 120 150 150 150 150 150 150 350 120 120 120 150 120 150 230 230 mVp-p max -20 to 0C*2 160 160 160 180 180 180 180 180 180 400 160 160 160 180 160 180 350 350 TEMPERATURE ACE 0 to +50C 50 50 50 90 120 150 180 240 300 480 50 50 50 120 50 240 120 150 COEFFICIENT mV max *3 DRIFT mV max 20 20 20 36 48 60 72 96 120 192 20 20 20 48 20 96 48 60 OUTPUT VOLTAGE SETTING V 2.00-2.20 3.25-3.45 4.99-5.30 7.20-7.80 11.5-12.5 14.4-15.6 17.3-18.7 23.0-25.0 33.0-35.0 46.0-50.0 4.99-5.30 4.99-5.30 4.99-5.30 11.5-12.5 4.99-5.30 23.0-25.0 11.5-12.5 14.4-15.6 OUTPUT VOLTAGE ADJUSTMENT RANGE V 1.60-2.60 2.60-3.60 4.00-5.50 6.00-8.20 9.00-13.2 13.2-16.5 16.5-19.2 19.2-26.4 27.2-37.4 38.4-52.8 4.99-5.50 3.00-5.50 4.99-5.50 7.50-13.2 4.99-5.50 15.0-26.4 9.60-13.2 13.2-16.5 OVERCURRENT PROTECTION A Works over 105%min of rated current or 101%min of peak current. Automatic recovery. OVERVOLTAGE PROTECTION V 3.00-4.80 4.00-5.25 Works at 115 - 140% of rated voltage Remotesensing, remote ON/OFF, alarm (LV) Remote ON/OFF Same as W,Z FUNCTION *1 Operating condition of peak current : Peak current is less than 10sec., duty is less than 35% *8 Ratings of V2 can draw up to 50% of rated current at the time of 0A in load of V1. and average current is less than rated current. (rated current2 at Module W, Z, 9, Q and V) (Only module S,T,U. refer to instruction manual 4.2 for details.) *2 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN : * Each output of module Y-Z, 9, Q and V is a ground common type (not isolated),each output of RM101). Ripple and Ripple Noise is measured by using measuring board with capacitor of module S,T and U is isolated. 22mF within 150mm from output terminal. = For ACE300F,450F and 650F , input and output terminals can be set at the same side if Input *3 Drift is changed in DC output for an eight hour period after half-hour warm-up at 25C, with module (code:I) is installed instead of the most left module. the input voltage held constant at the rated input/output. * Modules which can correspond to medical electrical equipment (UL2601-1, EN60601-1) are *4 When the output voltage of module A is used less than 2.0V, keep minimum output current 2.6A. all modules except module S, T and U. Refer to instruction manual 7. for details. *5 It is a value from 0 to rated output current1. The current on non-measurement side is fixed. *6 It is a value from 0 to rated output current2. The current on non-measurement side is fixed. *7 The sum of +power and -power must be less than output power(Y:50W, W:76.8W, Z:75W, 9:76.8W, Q:153.6W, V:165W). Block diagram INPUT INRUSH RECTIFIER OUTPUT NOISE ACTIVE DC OUTPUT AC85 - 264V CURRENT AND MODULE FILTER FILTER LIMITING FILTER 2-6 SLOTS REMOTE ON/OFF FG DETECTED AUXILIARY OUTPUT ALARM(LV) POWER VOLTAGE AUXILIARY POWER(AUX) FUSE FAN ACE300F : AC250V8A ACE450F : AC250V10A ACE650F : AC250V15A ACE900F : AC250V20A DETECTED LINE ALARM ALARM(PR) VOLTAGE ACE-3