. DC-DC Converters Bus Converter Power Module Type Low Profile Isolated Safety OCP OVP Parallel World wide Remote Approvals Operation ON/OFF DBS-series Feature Ideal for distributed power systems Thin and small size Built-in overcurrent, overvoltage and thermal protection circuits Built-in remote ON/OFF (on both side of input and output) Inverter operating monitoring (IOG) Mounting hole (M3 tapped) The beet noise is decreased by installing of the crystal oscillator (DBS700) CE marking Low Voltage Directive RoHS Directive Safety agency approvals UL, C-UL recognized, TuV approved 5-year warranty July 03, 2020 DBS-1. Ordering information DC-DC Converters Bus Converter Power Module Type DB S 150 A 15 DBS100A/DBS150A 1 2 3 4 5 1 Ser ies name R 2 Single output 3 Output wattage 4 Input voltage A : DC110V input 5 Output voltage MODEL DBS100A05 DBS100A13R8 DBS150A12 DBS150A15 DBS150A24 MAX OUTPUTWATTAGE W 100 100.7 150 150 151 DC OUTPUT 5V 20A 13.8V 7.3A 12V 12.5A 15V 10A 24V 6.3A SPECIFICATIONS MODEL DBS100A05 DBS100A13R8 DBS150A12 DBS150A15 DBS150A24 VOLTAGE V DC45- 160 DC66 - 160 1 INPUT CURRENT A * 1.11typ 1.10typ 1.57typ 1.59typ 1.58typ *1 EFFICIENCY % 82typ 83typ 87typ 86typ 87typ VOLTAGE V 5 13.8 12 15 24 CURRENT A 20 7.3 12.5 10 6.3 LINE REGULATION mV 20max 60max 40max 60max 95max LOAD REGULATION mV 40max 150max 100max 150max 190max 2 0to +85 * 80max 120max 120max 120max 120max C RIPPLE mVp-p *2 -20- 0 140max 160max 160max 160max 160max C 2 0to +85 * 100max 150max 150max 150max 150max C OUTPUT RIPPLE NOISE mVp-p 2 -20- 0 * 150max 180max 180max 180max 180max C 0to +65 50max 180max 120max 180max 280max C TEMPERATURE REGULATION mV -20to +85 85max 310max 200max 310max 480max C 3 DRIFT mV * 20max 60max 40max 60max 90max ( , ) START-UP TIME ms 200max DCIN 110V Io=100% ( ), OUTPUTVOLTAGE ADJUSTMENT RANGE Fixed TRM pin open 60 - 110% adjustable by external VR or external voltage OUTPUTVOLTAGE SETTING V 4.90- 5.20 13.25- 14.35 11.60 - 12.60 14.40- 15.60 23.04- 24.96 OVERCURRENT PROTECTION Worksover 105%ofratingand recovers automatically PROTECTION OVERVOLTAGE PROTECTION 5.75- 7.00V 15.87- 19.32V 13.80 - 16.80V 17.25- 21.00V 27.60- 33.60V CIRCUIT AND REMOTE SENSING Provided OTHERS ( ) REMOTEON/OFF Provided On both side of input and output , , , ( ) INPUT-OUTPUT AC3 000V 1minute Cutoff current= 10mA DC500V 50M min 20 15 W t C , , , ( ) INPUT-FG AC2 000V 1minute Cutoff current= 10mA DC500V 50MW min 20t15C ISOLATION , , ( ) OUTPUT-FG AC500V 1minute Cutoff current= 100mA DC500V 50M min 20 15 W t C , , , ( ) OUTPUT-RC2RC3 AC100V 1minute Cutoff current= 100mA DC100V 10M min 20 15 W t C 4 , * ( ), ( )( ), , ( , ) OPERATINGTEMP.HUMID.ANDALTITUDE -20 to +85C On aluminum base plate 20 - 95%RH Non condensing Refer to Derating 3 000m 10 000feet max , , ( ), , ( , ) STORAGE TEMP.HUMID.ANDALTITUDE -40 to +85 20- 95%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT 2 , ( ), , , VIBRATION 10- 55Hz 49.0m/s 5G 3minutes period 60minutes each alongX Y and Z axis 2 ( ), , IMPACT 196.1m/s 20G 11ms once each alongX Y andZ axis , , SAFETY AGENCY APPROVALS UL60950-1 C-UL EN60950-1 ( ) CASE SIZE/WEIGHT 61 12.7 116.8mm 2.4 0.5 4.6 inches W H D / 150g max X X X X X X OTHERS ( ) COOLINGMETHOD Conduction cooling e.g. heatradiation from the aluminum base plate to the attached heat sink *1 At rated input(DC110V) and rated load. *2 Ripple and ripple noise is measured by using measuring board with the recommended capacitor Co & the film capacitor 0.1mF. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:RM101). Refer to the manual. *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *4 Please consult us in regard to use from -40C. July 03, 2020 DBS-2