Ordering information DC-DC Converters Power Module type DP A 500 F -360 DPA500F 12345 1Series name R 2Single output 3Output wattage 4Universal input 5Output voltage MODEL DPA500F-360 AC INPUT V AC85 - 264 AC170 - 264 MAX OUTPUT WATTAGE W 500 750 DC OUTPUT VOLTAGE V DC300 - 360 DPA SPECIFICATIONS MODEL DPA500F-360 VOLTAGE V AC100/120 AC200/240 VOLTAGE RANGE V AC85 - 170 AC170 - 264 POWER FACTOR CORRECTION RANGE V AC85 - 255 ( ) ( ) CURRENT A 5.6typ ACIN 100V 4.0typ ACIN 200V FREQUENCY Hz 47-63 INPUT ( ) ( ) APPARENT POWER VA 560typ ACIN 100V 800typ ACIN 200V ( ) ( ) INRUSH CURRENT A 15typ ACIN 100V 30typ ACIN 200V ( ) ( ) EFFICIENCY % 90typ ACIN 100V 95typ ACIN 200V ( ) POWER FACTOR 0.98typ Complies with IEC61000-3-2 LEAKAGE CURRENT mA Less than 0.3 WATTAGE W 500 750 OUTPUT ( ) VOLTAGE V DC300 - 360 Automatically changes according to input voltage OVERVOLTAGE PROTECTION V DC390 - 440 , , , IOG Inverter operation monitoring Open-collector output Maximum sink current 5mA Maximum allowance voltage 35V PROTECTION , , , CIRCUIT AND PR Power-ready signal Open-collector output Maximum sink current 5mA Maximum allowance voltage 35V OTHERS , , AUX Auxiliary power supply for external signal Output voltage:10 - 20V maximum Output current:10mA OTHERS Inrush current protection, Parallel operation possible (Current balancing function), Thermal protection INPUT-OUTPUT Non isorated , , , ( ) ISOLATION INPUT-FG AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature W OUTPUT-FG AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) W , *1 ( ), ( )( ), , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE -20 to +85 Aluminum base plate 20 - 95%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max C , , ( ), , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -40 to +85 20 - 95%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT 2 VIBRATION 10 - 55Hz, 49.0m/s (5G), 3minutes period, 60minutes each along X, Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis , , , SAFETY AGENCY APPROVALS UL60950-1 CSA C22.2 No.60950-1 EN60950-1 EN50178 Complies with DEN-AN and IEC60950-1 CASE SIZE/WEIGHT 58 12.7 130mm (W H D) / 150g max X X X X OTHERS ( ) COOLING METHOD Conduction cooling e.g. heat radiation from the aluminum base plate to the attached heat sink *1 Please consult us in regard to use from -40C. DPA-2DPA500F External view DC OUT Recomending size for processing PCB Name Plate 5.08 5.08 (TOP VIEW) 22.86 0.5 0.5 7.62 7.62 12.7 3.5 5.08 25.4 5.08 0.5 58 0.3 0.9 0.3 Outline 2-M4(Depth:6mm) Mounting Hole for FG 2- 4.5 2-M3(Depth:6mm) Mounting Hole 10-1.7 for Heat Sink Name Plate 1.2 22.86 5.08 25.4 5.08 7.62 7.62 0.2 1.0 0.2 ACIN Weight: 150g or less. Input Output Pin 5.08 5.08 Tolerance: 0.3 0.2 0.2 Case: PBT Base Plate: Aluminum Dimensions in mm. Mounting torque Dimensions in mm, =inches Mounting Hole for Heat Sink: 1.2 0.4Nm(5.0kgfcm)max Div. : 0.2inch t = 0.5 Mounting Hole for FG: 1.2Nm(12.8kgfcm)max DPA Performance data STATIC CHARACTERISTICS OUTPUT VOLTAGE FOR INPUT ( ) ( ) HARMONIC CURRENT AC100V HARMONIC CURRENT AC200V 10.0 10.0 Harmonic current standard of class A (at odd number) Harmonic current standard of class A (at odd number) 1.0 1.0 0.1 0.1 0.01 0.01 1 10 20 30 40 1 10 20 30 40 HARMONIC ORDER HARMONIC ORDER DPA-3 Powered by TCPDF (www.tcpdf.org) HARMONIC CURRENT A SR CB R +V IOG V PR AUX 5.3 1 119.38 1 130 0.5 3.5 118.11 1 5.3 0.5 119.38 1 5.3 HARMONIC CURRENT A 119.38 4.7 118.11 4.65