Ordering information Small, Single phase input type (1-Stage filter) EAC -10 -472 -O EAC/EAM/EAP series 1 2 3 4 1 Series Name R 2 Rated Current 3 Line to ground capacitor code: Refer to table 1.1. table1.1 Line to ground capacitor code EACEAMEAP Line to ground Leakage Current Code capacitor (Input 125/250V 60Hz) (nominal value) 000 5 A / 10 A max Not Provided 101 12.5 A / 25 A max 100pF 221 25 A / 50 A max 220pF 331 37.5 A / 75 A max 330pF 471 50 A / 100 A max 470pF 681 75.5 A / 150 A max 680pF 102 0.13 mA / 0.25mA max 1,000pF 222 0.25 mA / 0.5 mA max 2,200pF 332 0.38 mA / 0.75mA max 3,300pF 472 0.5 mA / 1.0 mA max 4,700pF *When the line to ground capacitor code is different, the attenuation characteristic is different. 4 Option D :DIN rail installation type The terminal cover is retracted inside the unit DIN rail installation type is option * The dimensions change when the option is set. Refer to External view. Features of EAC/EAM/EAP series -Single Phase 250VAC (1-Stage filter) -Small size -Quic k and easy push-down terminal Just connect the wires, push-down and tighten the screws with a screwdriver EAC : Attenuation type from 150kHz to 1MHz EAM : Low leakage current type EAP : Outside impulse attenuation type Specifications EAC-03-472 EAC-06-472 EAC-10-472 EAC-16-472 EAC-20-472 EAC-30-472 No. Items EAM-03-000 EAM-06-000 EAM-10-000 EAM-16-000 EAM-20-000 EAM-30-000 EAP-03-472 EAP-06-472 EAP-10-472 EAP-16-472 EAP-20-472 EAP-30-472 1 Rated Voltage V AC 1f 250 / DC250 2 Rated Current A 3 6 10 16 20 30 3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity 4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 500MW min at room temperature and humidity 5 Leakage current Refer to table 1.1 6 DC resistance 180mW max 110mW max 40mW max 20mW max 10mW max 6mW max 7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve) 8 Operating temperature -40 to +85C (Refer to Derating Curve) 9 Operating humidity 20 to 95%RH (Non condensing) 10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing) 2 11 Vibration 10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis 2 12 Impact 196.1m/s (20G), 11ms Once each X, Y and Z axis 13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input) 14 Case size (without projection) /Weight 39X30X85 mm 1.54X1.18X3.35 inches (WXHXD) /170g max (Option : -D refer to external view) Circuit Diagram Derating Curve Case 100 80 3 1 60 CY LINE LOAD 40 CY 2 4 20 0 -404-30-20 0 50 55 60 70 80 90 : Mounting Plate Ambient Temperature C CY : Line to ground capacitor October 06, 2021 EA/ES-1 Load Factor % EAC/EAM/EAP series External view This product is shipped in the following condition,because it is equipped with push-down terminals. 1The terminal cover is retracted inside the unit. 2The screws for connecting the terminals are held in the up right position. Standard Type 85 3.35 0.5 75 2.95 72 2.5 21 2.83 0.1 0.83 M4 11.5 Terminal cover Mounting Plate Protection Earth 0.45 2-M4 2-M4 Name Plate Output Input Terminal Terminal Terminal cover 2-f4.8 M4 Terminal cover 0.19 Mounting Hole Protection Earth Closed the terminal cover Tolerance : 1 0.04 Weight : 170g max Mounting Plate : Iron (surface finishing:nickel plating)=1.0 0.04 CasePBT Dimensions in mm, =inches Terminal block screw tightening torque M4 1.6Nm(16.9kgfcm)max DIN rail installation Type +2 8.5 -1 85 3.35 0.33 72 2.83 M4 2.5 21 Protection Earth 0.1 0.83 Terminal cover Mounting Plate 11.5 0.45 2-M4 2-M4 Name Plate Input Output Terminal Terminal Terminal cover M4 Terminal cover Protection Earth Closed the terminal cover Tolerance : 1 0.04 Weight : 170g max Mounting Plate : Iron (surface finishing:nickel plating)=1.0 0.04 CasePBT Dimensions in mm, =inches Terminal block screw tightening torque M41.6N m(16.9kgfcm)max DIN rail (4.2) 0.17 Note when installing the EMI/EMC DIN rail Filter on a DIN rail. When the EMI/EMC Filter is grounded through the DIN rail, the proper noise attenuation may not Name Plate be achieved. Be sure to connect the protection earth (PE) of the EMI/EMC Filter body to the earth. At least one PE connection is required. October 06, 2021 EA/ES-2 (9) 9.7 9.7 0.35 0.38 0.38 12.7 2 30 0.5 12.7 1.18 0.08 7 30 2 0.5 0.28 1.18 0.08 0.5 31.5 1.24 39 39 1.54 1.54