Ordering information
Small,High-voltage pulses common mode noise filters (1-Stage filter)
EAP -10 -472 -O
EAP series
1 2 3 4
1Model Name
2Rated Current
3Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Line to ground
Leakage Current
Code capacitor
(Input 125/250V 60Hz)
(nominal value)
000 5 A/ 10 A max Not Provided
101 12.5 A/ 25 A max 100pF
221 25 A/ 50 A max 220pF
331 37.5 A/ 75 A max 330pF
471 50 A/ 100 A max 470pF
681 75.5 A/ 150 A max 680pF
102 0.13 mA/ 0.25mA max 1000pF
222 0.25 mA/ 0.5 mA max 2200pF
332 0.38 mA/ 0.75mA max 3300pF
472 0.5 mA/ 1.0 mA max 4700pF
* When the line to ground capacitor code is
different, the attenuation characteristic is
different.
The terminal cover is retracted inside the unit DIN rail installation type is option 4Options
D:DIN rail installation type
* The dimensions change when the option is set.
Refer to External view.
Features of EAP series
Small,High-voltage pulses common mode noise filters(1-Stage filter)
- Single Phase 250 VAC -Small-size
-Quick and easy push-down terminal
Just connect the wires,push-down and tighten
the screws with a screwdriver
Specifications
No. Items EAP-03-472 EAP-06-472 EAP-10-472 EAP-16-472 EAP-20-472 EAP-30-472
1 Rated Voltage[V] AC 1f 250 / DC250
2 Rated Current[A] 3 6 10162030
3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 500MW min at room temperature and humidity
5 Leakage current 125/250V 60Hz 0.5mA/1.0mA max
6 DC registance 180mW max 110mW max 40mW max 20mW max 10mW max 6mW max
7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve)
8 Operating temperature -40 to +85C (Refer to Derating Curve)
9 Operating humidity 20 to 95%RH (Non condensing)
10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing)
2
11 Vibration 10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis
2
12 Impact 196.1m/s (20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
14 Case size (without projection) /Mass 39X30X85 mm (WXHXD) /170g max (Option : -D refer to external view)
Circuit Diagram Derating Curve
Case
100
80
3
1
60
CY
LINE
LOAD
40
CY
4
2
20
Noise
Filter
0
-40 -30 -20 40 50 55 60 70 80 90
: Mounting Plate Ambient Temperature [C]
CY : Line to ground capacitor
I-6
OG PQKUGHKNVGT
'#KPFF +
Load Factor [%]EAC,EAM,EAP series
External view
This product is shipped in the following condition,because it is equipped with push-down terminals.
1The terminal cover is retracted inside the unit.
2The screws for connecting the terminals are held in the up right position.
Standard Type
85
0.5
75
72
M4
2.5 21
Protection Earth
11.5
Terminal cover Mounting Plate
2-M4 2-M4
Name Plate
Output
Input
Terminal
Terminal
2-f4.8 M4 Terminal cover
Terminal cover
Mounting Hole Protection Earth
Closed the terminal cover
Tolerance : 1
Mass : 170g or less
Mounting Plate : Iron (surface finishing:nickel plating) =1.0
Case PBT
Dimensions in mm
Terminal block screw tightening torque M4 1.6N m(16.9kgf cm)max
DIN rail installation Type
+2
8.5 -1
85
72
M4
2.5 21
Protection Earth
11.5
Mounting Plate
Terminal cover
2-M4
2-M4
Name Plate
Input
Output
Terminal Terminal
Terminal cover
M4
Terminal cover
Protection Earth
Closed the terminal cover
Tolerance : 1
Mass : 170g or less
Mounting Plate : Iron (surface finishing:nickel plating) =1.0
Case PBT
Dimensions in mm
Terminal block screw tightening torque M4 1.6N m(16.9kgf cm)max
DIN rail
Note when installing the noise
lter on a DIN rail.
DIN rail
When the noise lter is grounded through the
DIN rail, the proper noise attenuation may not be
Name Plate
achieved.
Be sure to connect the protection earth (PE) of
Noise
the noise lter body to the earth.
Filter
I-7
OG PQKUGHKNVGT
'#KPFF +
(9)
9.7 9.7
12.7
2
30
12.7
7 30 2
0.5
31.5
39
39