Ordering information Three phase input type(1-stage filter) JAC -30 -683 -O JAC series(6-30A) 1 2 3 4 1 Model Name R 2 Rated Current 3 Line to ground capacitor code:See table 1.1. table1.1 Line to ground capacitor code Leakage Current Line to ground Code (Input 250/500V 60Hz) capacitor (Only 224 is 250/400V 60Hz) (nominal value) 103 0.5mA / 1.0mA max 10,000pF 223 1.0mA / 2.0mA max 22,000pF 683 2.5mA / 5.0mA max 68,000pF 224 15mA / 24mA max 220,000pF *When the line to ground capacitor code is different, the attenuation characteristic is different. 4 Option D:DIN rail installation type The dimensions change when the option is set. * Refer to External view. The terminal cover is retracted inside the unit DIN rail installation type is option H:Ultra high-attenuation type 103,223,683 is applied. U:Improve differential mode attenuation (Rated voltage 250V) Features of JAC series Compact and low profile, common mode EMI/EMC filters in 150kHz to 1MHz (1-stage filter) - Three Phase 500 VAC - Push down type terminal block - Selectable leakage current value, Ultra high-attenuation type 224 for EU (Y type with neutral earth system) Specifications No. Items JAC-06-683 JAC-10-683 JAC-20-683 JAC-30-683 1 Rated Voltage V AC Three Phase 500 (voltage range:528 max) 50/60Hz *1 *2 2 Rated Current A 6 10 20 30 3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity *3 4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MW min at room temperature and humidity *4 5 Leakage current 250/500V 60Hz 2.5mA/5.0mA max 6 DC resistance 100mW max 45mW max 15mW max 8mW max 7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve) 8 Operating temperature -40 to +85C (Refer to Derating Curve) 9 Operating humidity 20 to 95%RH (Non condensing) 10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing) 2 11 Vibration 10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis 2 12 Impact 196.1m/s (20G), 11ms Once each X, Y and Z axis 13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC 63X44X132 mm (WXHXD) (Option: -D refer to external view) 14 Case size (without projection) 2.48X1.73X5.20 inches (WXHXD) 15 Weight 440g max *1 Capacitor code 224 : Three Phase D-connection 400 (440 max), Y-connection 500 (528 max). *2 JAC-OO-OOO-U : Three Phase 250 (275 max). *3 Capacitor code 224 : 2,800VDC (Cutoff Current = 10mA), 1 minute at room temperature and humidity. *4 Capacitor code 224 : Isolation resistance specification is deleted. Circuit Diagram Derating Curve (1) Line to ground capacitor code : 103, 223, 683 (2) Line to ground capacitor code : 224 100 CaseCase CaseCase LINELINE LOADLOAD LINELINE LOADLOAD 80 CaseCase CaseCase 1 1 4 4 1 1 4 4 LINELINE LOADLOAD LINELINE LOADLOAD 70 2 2 5 5 2 2 5 5 60 1 1 4 4 1 1 4 4 3 3 6 6 3 3 6 6 40 2 2 5 5 2 2 5 5 CX CXCX CXCX CX CX CCXX CXCX CX 3 3 CX CXCX CXCX CX CX CCXX CCXX CX 6 6 3 3 6 6 20 10 CX CXCX CXCX CX CX CCXX CCXX CX CX CXCX CXCX CX CX CCXX CXCX CX 0 CY CY CY CY CY CY -40 -30 -20 40 50 60 70 80 90 CY CY CY CY CY CY CX : CLine to line capacitorX : Line to line capacitor CX : CLine to line capacitorX : Line to line capacitor Ambient Temperature CY : CLine to ground capacitorY : Line to ground capacitor CY : CLine to ground capacitorY : Line to ground capacitor CX : CLine to line capacitorX : Line to line capacitor CX : CLine to line capacitorX : Line to line capacitor : Mounting Plate: Mounting Plate : Mounting Plate: Mounting Plate CY : CLine to ground capacitorY : Line to ground capacitor CY : CLine to ground capacitorY : Line to ground capacitor (3) Line to ground capacitor code : 103, 223, 683 (4) Line to ground capacitor code : 224 : Mounting Plate: Mounting Plate : Mounting Plate: Mounting Plate CaseCase CaseCase LINELINE LOADLOAD LINELINE LOADLOAD Option : U Option : U CaseCase CaseCase LIN1ELIN1E L4OADL4OAD LIN1ELIN1E L4OADL4OAD 2 2 5 5 2 2 5 5 1 1 4 4 1 1 4 4 3 3 6 6 3 3 6 6 2 2 5 5 2 2 5 5 3 3 6 6 3 3 CX CXCX CXCX CX CX CCXX CXCX CX 6 6 CX CXCX CXCX CX CX CCXX CCXX CX CX CCXX CXCX CX CX CXCX CXCX CX CX CCXX CCXX CX CX CXCX CXCX CX CY CY CY CY CY CY CY CY CY CY CY CY CX : CLine to line capacitorX : Line to line capacitor CX : CLine to line capacitorX : Line to line capacitor CY : CLine to ground capacitorY : Line to ground capacitor CY : CLine to ground capacitorY : Line to ground capacitor CX : : Mounting PlateCLine to line capacitorX : : Mounting PlateLine to line capacitor CX : : Mounting PlateCLine to line capacitorX : : Mounting PlateLine to line capacitor CY : CLine to ground capacitorY : Line to ground capacitor CY : CLine to ground capacitorY : Line to ground capacitor : Mounting Plate: Mounting Plate : Mounting Plate: Mounting Plate September 16, 2021 JAC-1 Load Factor % JAC series(6-30A) External view This product is shipped in the following condition, because it is equipped with push-down terminals. 1The terminal cover is retracted inside the unit. 2The screws for connecting the terminals are held in the up right position. Standard Type 132 5.20 Terminal Cover (Terminal Block screw pitch) 119 2-f5.5 0.22 2.5 32 4.69 0.10 1.26 Mounting Hole 3-M4 Output Terminal 3-M4 Name Plate Input Terminal Mounting Plate M4 Protection Earth (Mounting Hole pitch) 118 4.61 Terminal cover Close the terminal cover Tolerance : 1 0.04 Weight : 440g max Mounting Plate : Iron(surface finishing : nickel plating) t=1.0 0.04 Case : PBT Dimensions in mm, =inches Terminal block screw tighting torque M4 : 1.6N-m(16.9kgf-cm)max 4.5 4.5 0.18 0.18 DIN rail installation Type 9 2 132 5.20 0.35 Terminal Cover 119 (Terminal Block screw pitch) 2.5 32 4.69 0.10 1.26 3-M4 3-M4 Output Input Terminal Name Plate Terminal Mounting Plate M4 Protection Earth Terminal cover Close the terminal cover Tolerance : 1 0.04 Weight : 440g max Mounting Plate : Iron(surface finishing : nickel plating) t=1.0 0.04 Case : PBT Dimensions in mm, =inches Terminal block screw tighting torque M4 : 1.6N-m(16.9kgf-cm)max 4.5 DIN rail 4.5 0.18 0.18 Note when installing the EMI/ DIN rail EMC Filter on a DIN rail. When the EMI/EMC Filter is grounded through Name Plate the DIN rail, the proper noise attenuation may not be achieved. Be sure to connect the protection earth (PE) of the EMI/EMC Filter body to the earth. September 16, 2021 JAC-2 13.3 13.3 (9) 0.52 0.52 8 9.7 8 9.7 0.31 0.38 0.38 0.31 44 2 7 44 2 1.73 0.08 1.73 0.08 63 50 0.28 1.97 2.48 63 2.48