Ordering information Ultra high-attenuation type of common mode noise from 10kHz to 1MHz NAH -10 -472 -O NAH series 1 2 3 4 1Model Name 2Rated Current 3Line to ground capacitor code:See table 1.1. table1.1 Line to ground capacitor code Line to ground Leakage Current Code capacitor (Input 125/250V 60Hz) (nominal value) 000 5 A/ 10 A max Not Provided 101 12.5 A/ 25 A max 100pF 221 25 A/ 50 A max 220pF 331 37.5 A/ 75 A max 330pF 471 50 A/ 100 A max 470pF 681 75.5 A/ 150 A max 680pF 102 0.13 mA/ 0.25mA max 1000pF 222 0.25 mA/ 0.5 mA max 2200pF 332 0.38 mA/ 0.75mA max 3300pF 472 0.5 mA/ 1.0 mA max 4700pF The terminal cover is retracted inside the unit DIN rail installation type is option *1 When the line to ground capacitor code is different, the attenuation characteristic is different. 4Options D:DIN rail installation type * The dimensions change when the option is set. Refer to External view. Features of NAH series Ultra high-attenuation type of common mode noise from 10kHz to 1MHz - Single Phase 250 VAC - Quick and easy push-down terminal Just connect the wires, push down and tighten the screws with a screwdriver Specifications No. Items NAH-06-472 NAH-10-472 NAH-16-472 NAH-20-472 NAH-30-472 1 Rated Voltage V AC 1f 250 / DC250 2 Rated Current A 6 10162030 3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity 4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MW minute at room temperature and humidity 5 Leakage current 125/250V 60Hz 0.5mA/1.0mA max 6 Voltage drop 1.0V max 7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve) 8 Operating temperature -40 to +85C (Refer to Derating Curve) 9 Operating humidity 20 to 95%RH (Non condensing) 10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing) 2 11 Vibration 10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis 2 12 Impact 196.1m/s (20G), 11ms Once each X, Y and Z axis 13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN133200 VDE0565 Teil3-1, ENEC (At only AC input) 14 Case size (without projection) /Mass 53X41X92 mm (WXHXD) /300g max (Option : -D refer to external view) Circuit Diagram Derating Curve Case 100 80 1 3 60 CY LOAD LINE 40 CY 20 2 4 Noise 0 Filter -40 -30 -20 40 50 55 60 70 80 90 Ambient Temperature C CY : Line to ground capacitor : Mounting Plate I-5 Load Factor % NAC,NAM,NAP,NAH series External view This product is shipped in the following condition, because it is equipped with push-down terminals. 1The terminal cover is retracted inside the unit. 2The screws for connecting the terminals are held in the up right position. Standard Type 92 0.5 (2.5) 27 82 2-f4.8 77 2-Protection Earth 8 Mounting Hole Input Terminal Output Name Plate Terminal Output Input Terminal Terminal 6-M4 Terminal cover Terminal cover Mounting Plate Closed the terminal cover Tolerance : 1 Mass : 300g or less Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 Case : PBT Dimensions in mm Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max DIN rail installation Type (2.5) 27 92 (11) 77 8 2-Protection Earth Input Terminal Output Name Plate Terminal Output Input Terminal Terminal 6-M4 Mounting Plate Terminal cover Terminal cover Closed the terminal cover Tolerance : 1 Mass : 300g or less Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 Case : PBT Dimensions in mm Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max DIN rail Note when installing the noise lter on a DIN rail. DIN rail When the noise lter is grounded through the DIN rail, the proper noise attenuation may not be Name Plate achieved. Be sure to connect the protection earth (PE) of Noise the noise lter body to the earth. Filter I-6 15 15 (9) (2) 41 12 (2) 7 41 0.5 45 12 53 53